1 Hold: Freezes the display reading. Reading is released when button is pushed a second time.
2 Fluke Connect™ radio: Activates the radio and starts the wireless module discovery procedure; Wireless icon shows in the display when the radio is on. Deactivates the radio when the measuring procedure is finished.
3 Min Max: On first push, display shows maximum input. On subsequent pushes, minimum and average inputs are shown. Works in current, voltage and frequency modes.
4 Zero: Removes dc offset from dc current measurements. This button sometimes appears in yellow and doubles as the shift button, corresponding to yellow functions scattered around the dial.
5 Hz: Frequency.
6 Inrush: Measures inrush current by taking approximately 400 samples over a 100-millisecond period and calculating the starting current envelope.
7 °F/°C: Temperature, in Fahrenheit or Celsius.
8 AC/DC: On selected models, permits user to toggle between ac and dc measurements.
9 Range: Allows the user to switch from auto range to manual range.
10 Log: Initiates data recording process.
11 Low pass filter: Aims to eliminate electronic interference that might distort readings.
12 The beaming orb: On/off switch for display backlight.
Notes:
  • The array of buttons displayed here is a composite image of buttons found on various Fluke clamp meters. No single model contains all of these functions.
  • On some models, a few function icons are displayed in yellow. This indicates the meter’s yellow function button must be pressed to select those measurements.

Was this helpful?
Yes
No
Recommended Products
Recommended Resources
 
©2016 Fluke Corporation. Specifications subject to change without notice. 6005011