Keeping your world up and running.®

Fluke 1745 Power Quality Logger

Disturbance Analyzers - Fluke 1745 three-phase power quality logger is capable of logging up to 500 power parameters for up to 85 days.

Get a Free Demo
Fluke 1745 Power Quality Logger
  • Fluke 1745 Power Quality Logger
  • Fluke 1745 Power Quality Logger
Overview
Features
Reviews
Specs
Models
Accessories
Resources
  • Power quality logging is easy with a compact and rugged Fluke power meter

    The Fluke 1745 Three-phase Power Quality Logger is an everyday power meter for technicians who troubleshoot and analyze power quality issues. Capable of simultaneously logging up to 500 power parameters for up to 85 days and monitoring for events, these power loggers help uncover intermittent and hard-to-find power quality issues. The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard.

    Applications

    • Disturbance analysis – Uncover root cause of equipment malfunction for later mitigation and predictive maintenance
    • Quality of service compliance – Validate incoming power quality at the service entrance
    • Power quality studies – Assess baseline power quality to validate compatibility with critical systems before installation
    • Load studies – Verify electrical system capacity before adding loads
    • Energy and power quality assessment – Validate performance of facility improvements by quantifying energy consumption, power factor, and general power quality before and after improvements
    • Plug and play: Setup in minutes with automatic current probe detection and powering
    • Installs inside the cabinet: Compact, fully-insulated housing and accessories fit easily in tight spaces next to live power
    • Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables
    • Monitors power for the long-term: Data can be downloaded during recording without interruption
    • Measure voltage with premium accuracy: IEC61000-4-30 Class-A compliant voltage accuracy (0.1%)
    • Quickly validate quality of power: Assess power quality according to EN50160 power quality standard with statistical overview
    • Rugged and reliable: Designed for everyday field use with no moving parts and durable insulated case with two year warranty

    Loggers for every application

    The portable Fluke 1745 Power Quality Logger is designed for easy installation and use, anywhere in low- and medium-voltage applications.

    The advanced IP50 power quality logger has the same measurement capability as the 1744, plus real-time LCD, five hour UPS.

    Features:

    • Measurement of common power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
    • Measurement of voltage and current harmonics to the 50th, unbalance, and mains signaling
    • Dust/water resistance: IP50
    • LED and LCD Displays
    • 5 hr UPS ride-through
    • Dimensions (H x W x D): 282 x 216 x 74 mm (11.5 x 8.8 x 3 in)
  • General Data
    Intrinsic error Refers to the reference conditions and is guaranteed for two years
    Warranty 2 years
    Recalibration interval 2 years recommended
    Quality system developed, designed, and manufactured according to DIN ISO 9001
    Reference conditions 23°C ±2 K; 74°F ±2 K , Vm = 230 V ±10%, 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
    Phase sequence L1, L2, L3
    Interval length 10 minutes
    Wye connection (L1, L2, L3 to N)
    Power supply 88 V ... 265 V AC
    Environment conditions Working temp. range -10°C to 55°C; 14°F to 131°F
    Operating temp. range 0°C to 35°C; 32°F to 95°F
    Storage temp. range -20°C to 60°C; -4°F to 140°F
    Reference temp. range 23°C ±2 K; 74°F ±2 K
    Relative humidity Class B2 acc. IEC 60654-1
    Housing robust, fully insulated housing and accessories
    Protection type IP50 as per EN 60529
    Safety IEC/EN 61010-1 600 V CAT III, 300 V CAT IV, pollution degree 2, double insulation
    Type test voltage 5.2 kV rms, 50 Hz / 60 Hz, 5 s
    EMC Emission IEC/EN 61326-1, EN55022
    Immunity IEC/EN 61326-1
    Voltage and Current Measurement
    Input voltage Input range VI P-N max 480 V AC
    Input range VI P-P max 830 V AC
    Max. overload voltage 1.2 VI
    Input range selection By job programming
    Connections P-P or P-N, 1- or 3-phase
    Nominal voltage VN ≤ 999 kV with PTs and ratio
    Input resistance App. 820 kΩ per chan. Lx-N Single phase (L1 or A, L2 or B, L3 or C connected): app. 300 kΩ
    Intrinsic uncenrtainty 0.1% of VI
    Voltage transformer Ratio: < 999 kV / VI
    Ration selection By job programming
    Current input with flexi set Input ranges II L1 or A, L2 or B, L3 or C, N 15 A / 150 A / 1500 A / 3000 A AC
    Measuring range 0.75 A … 3000 A AC
    Intrinsic uncertainty < 2% of II
    Position influence Max. ±2% of measured value – for distance conductor to meas. head > 30 mm
    Stray field influence < ±2 A AC for Iext = 500 A AC and distance to measuring head > 200 mm
    Temperature coefficient < 0.05% / K
    Current transformer Ratio ≤ 999 kA / II
    Ratio selection By job programming
    Connection 3-phase, 3-phase +N, 2 phase L1 or A and L3 or C (2 W-meter-method) 7 pole connector
    Current input for clamp Input ranges II L1 or A,
    L2 or B, L3 or C, N
    0.5 V nominal (for II) 1.4 Vpeak
    Intrinsic uncertainty < 0.3% of II
    Max. overload 10 V AC
    Input resistance App. 8.2 kΩ
    Current transformer Ratio Ω 999 kA / II
    Power systems Delta, 2-Element Delta, Wye, Single Phase, Split Single Phase
    Logger
    Power supply Functional Range 88 V to 660 V absolute, 50 Hz / 60 Hz
    100 V to 350 V DC Internal fuse: 630 mA T
    Power consumption 5 Watts
    Ride through Internal battery for typ. > 5 hours ride through with intelligent power management
    Fuse Power supply fuse can be replaced in service facility only. Supply can be connected in parallel to measuring inputs (up to 660 V)
    Display, indicators LEDs for status and voltage levels
    LC-display with backlight for voltage, current, active power, phase sequence.
    Memory Capacity 8 MB Flash-EPROM
    Intervals A function > 12000 intervals for > 85 days with 10 min intervals
    P function > 30000 intervals for > 212 days with 10 min intervals
    Events > 13000
    Memory model linear, circular
    Interface RS 232, 9600...115 000 Baud, automatic Baud rate selection, 3-wire communication
    Dimensions 282 x 216 x 74 mm (115 x 88 x 33 in)
    Weight approx. 3 kg
    Measurement A/D converter 16 bit, sample rate: 10.24 kHz
    Anti-aliasing filter FIR-Filter, fc =4.9 kHz
    Frequency response Uncertainty < 1% of Vm for 40 Hz to 2500 Hz
    Interval length 1, 3, 5, 10, 30 s, 1, 5, 10, 15, 60 minutes
    Averaging time for Min/max values ½, 1 mains period, 200 ms, 1, 3, 5 s
    Time base Resolution: 10 ms (at 50 Hz), deviation: 2 s/day at 23°C; 74°F ±2 K
    • Models
      Model Name Description  
      Fluke 1745 Fluke 1745 Power Quality Logger
       

      Includes:

      • Power Quality Logger Memobox
      • 4 Flexible probes 15/150/1500/3000 A with 2 m cable
      • CD-ROM with PQ Log software
      • RS232 interface cable and RS232-USB adapter
      • Test leads for voltages and power supply
      • 4 black dolphin clips
      • Color localization kit
      • Carrying bag
      • Test certificate with measurement values
      • Printed English manual
      • Multi-language manual CD
    • CarePlans
      Model Name Description  
      Fluke CarePlans Fluke Handheld Instruments CarePlans Fluke Store
    • Current Clamps
      Model Name Description  
      Fluke 3000A/6000A Fluke 3000A/6000A 36-Inch Flexi ProbeTM 4 Phase
      Fluke I1A/10A Clamp PQ1 Fluke I1A/10A 1 Phase Mini Current Clamp Set for Power Quality
      I1A/10A Clamp PQ3 Fluke I1A/10A Clamp PQ3 3-Phase 1A/10A
      I1A/10A Clamp PQ4 Fluke I1A/10A Clamp PQ4
      Fluke I20A/200A Fluke I20A/200A Clamp PQ3
      Fluke I20A/200A Fluke I20A/200A Clamp PQ4
      I5A/50A Clamp PQ1 Fluke I5A/50A Clamp PQ1
      I5A/50A Fluke I5A/50A Clamp PQ3
      Fluke I5A/50A Fluke I5A/50A Clamp PQ4
    • Related Products
      Model Name Description  
      Fluke 1745 Basic Fluke 1745 Basic Power Quality Logger
      Fluke 1744 Fluke 1744 Power Quality Logger
      Fluke 1744 Basic Fluke 1744 Basic Power Quality Logger
      Fluke 1743 Fluke 1743 Power Quality Logger
      Fluke 1743 Basic Fluke 1743 Basic Power Quality Logger
  •  Product Registration
     