Keeping your world up and running.®

Fluke 707 Loop Calibrator with Quick Click Knob

Loop Calibration - The new Fluke 707 Loop Calibrator is a cost-effective, integrated solution for calibration, repair and maintenance of current loops.

Get a Free Demo
Overview
Features
Reviews
Specs
Models
Accessories
Resources
  • The fastest, one-handed tool for loop checks.

    The Fluke 707 loop calibrator is a high performance solution for calibration, repair and maintenance of current loops. The new "Quick Click" knob making it extremely fast and easy to use. It features:

    • One handed user interface with "Quick Click" detented knob
    • mA sourcing, simulation and measurement
    • 0.015% accuracy and 0.001 mA resolution
    • Simultaneous mA and % of span display
    • Selectable step or ramp outputs
    • 24 V Loop supply with mA measure, including 250 Ω HART resistor
    • 0-28 V DC measurement to check Loop Voltage
    • Easy battery exchange without opening the case
    • Compact case with separate protective holster
    • Three year warranty
  • The fast, one-handed tool for loop checks. Just click to calibrate.

    This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:

    • Large display and simple, quick-click interface for easy one-handed operation.
    • Simultaneous mA and % readout for quick, easy interpretation of readings.
    • mA accuracy of 0.015%, superior to other loop calibrators in this price range.
    • 1 µA resolution for mA source, simulate and measure.
    • Push button 25% steps for fast, easy linearity checks.
    • 0-100% “span check” for fast confirmation of zero and span.
    • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
    • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
    • Measures V DC to 28 V.
    • Single 9 V battery that is easily changed without braking calibration seal
    • 0 - 20 mA or 4 - 20 mA default start up modes.
    • Innovative output adjustment dial with 1 µA and 100 resolution.
    • HART ™ mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.


    Safety conformance:

    CSA C22.2 No. 1010.1:1992

  • Specifications
    Current measurement Range 0 to 24 mA
    Resolution 0.001 mA
    Accuracy 0.015% Rdg + 2 LSD
    Current sourcing Range 0 to 20 mA or 4 to 20 mA
    Accuracy 0.015% Rdg + 2 LSD
    Drive capability 1200 Ω 950 Ω at 20 mA in HART mode
    Current simulation Range 0 to 20 mA or 4 to 20 mA
    Accuracy 0.015% Rdg + 2 LSD
    Ext. loop voltage requirement 12-30 V
    Loop power While measuring mA, 24 V
    Voltage measurement Range 0 to 28 V DC
    Resolution 1 mV
    Accuracy 0.015% Rdg + 2 LSD
    Environmental Specifications
    Operating temperature -10°C to 55°C
    Storage temperature -30°C to 60°C
    Humidity (without condensation) 0 to 90% (0°C to 35°C); 0 to 70% (35°C to 55°C)
    Temperature coefficient -10°C to 18°C, 28°C to 55°C, ±.005% of range per °C
    Safety Specifications
    Safety CSA C22.2 No. 1010.1:1992
    EMC EN50082-1:1992 and EN55022:1994 Class B
    Maximum voltage 30 V
    Mechanical and General Specifications
    Size 152 x 70 x 41 mm
    Weight 224 g (340 g including holster)
    Batteries One 9 V battery Alkaline
    Warranty Three years
    Shock and vibration Per MIL-T-28800 for a Class 2 Instrument
    Display current and % of span Yes
    Auto step, auto ramp Yes
    Span check Yes
    • Models
      Model Name Description  
      Fluke 707 Fluke 707 Loop Calibrator with Quick Click Knob
       

      Includes:

      • AC70A Alligator Clips
      • C10 protective yellow holster with Flex-Stand™
      • Instruction sheet
      • TL75 safety-designed test lead set
      • NIST- traceable calibration report and data