Keeping your world up and running.®

Fluke Ti105 a3001 FC iFlex® Kit

Fluke Ti105 Infrared Camera helps identify potential problems with ease. Discover the ultra-sleek design perfect for industrial and commercial applications today.

Get a Free Demo
Fluke Ti105 a3001 FC iFlex® Kit
  • Fluke Ti105 a3001 FC iFlex® Kit
  • Fluke Tools and Fluke Connect® Assets - all your data in one place
  • Fluke Connect® Asset Analysis showing current and thermal imaging
  • Fluke Ti105 Infrared Camera
Overview
Features
Reviews
Specs
Models
Accessories
Resources
  • Fluke Connect®

    See How It Works »
    Fluke Connect FAQs »

    Industrial and commercial professionals can save time and money by identifying problems before they become costly failures with the Ti105 a3001 FC iFlex® Kit. Connect the a3001 FC iFlex® AC Wireless Current Module to your test point and view the results up to 20 meters away on your 3000 FC DMM. The a3001 FC iFlex® module allows you to measure around tight, awkward spaces and/ or sizes and makes wire access easier. The Ti105 infrared camera comes standard with IR Fusion® Technology - the blending of digital and infrared images into a single image making precise documentation quick and easy. Upload all your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect.

    Simplify and streamline your reporting with our easy to use SmartView® software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite.

  • The Ti105 offers:

    • Fluke Connect ™ compatible – the largest network for wirelessly enabled tools. Take advantage of the benefits of Fluke Connect™ by sharing inspection results instantly, with any team member, at any time.
    • Rugged, lightweight, point-and-shoot focus free thermal camera
    • One-handed, easy-to-use user interface
    • Included SmartView® and SmartView Mobile App Analysis and Reporting Software

    The 3000 FC Wireless Multimeter offers:

    • AC and DC voltage measurements to 1000 V
    • AC and DC current with 0.01 mA resolution
    • Continuity, resistance, diode test, capacitance and frequency measurements
    • MIN/MAX Recording
    • CAT III 1000 V, Cat IV 600 V; IP54

    The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier. The a3001 FC offers:

    • One (1) true-RMS flexible current meter
    • One (1) iFlex i2500-10 flexible current probe
    • Measure up to 2500 A AC
    • Use as a standalone meter or as part of the system
    • Logging function for recording and saving up to 65,000 readings
    • Inrush function
    • Magnetic hanging strap
  • Fluke Ti105 Infrared Camera

    Detailed Specifications
    IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
    Spectral band 7.5 µm to 14 µm (long wave)
    Capture or refresh rate 30 Hz version
    NETD (thermal sensitivity) ≤ 0.10°C at 30°C target temp (100 mK)
    FOV (field of view) 22.5° H x 31° V
    IFOV (spatial resolution) 3.39 mRad
    Temperature measurement range (not calibrated below -10°C) -20°C to + 250°C (-4°F to 482°F)
    Temperature measurement accuracy ±2°C or 2% (at 25°C nominal, whichever is greater)
    Focus mechanism Focus-free 1.2 m (4 ft) and beyond
    IR Fusion® technology PIP (1.2 m (4 ft) to 4.6 m (15 ft)), full IR, full visible
    Fluke Connect compatibility
    Yes (where available)
    Color alarms -
    Standard palettes Blue-red, ironbow, grayscale and amber
    Ultra Contrast™ palettes -
    Hot/cold markers -
    User definable spot markers In SmartView® only
    Centerpoint Yes
    Centerbox (MIN/AVG/MAX) -
    Level and span control Manual and auto
    Minimum span in auto mode 5°C
    Minimum span in manual mode 2.5°C
    Minimum IR focus distance 122 cm (48 in)
    Weight 0.726 kg (1.6 lb)
    Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
    LCD display 3.5 inch diagonal (portrait format)
    Visible camera 2 megapixel industrial-grade
    Minimum parallax ~122 cm (48 in)
    IR-PhotoNotes™ annotation system -
    Laser pointer Yes
    Torch Yes
    Electronic (cardinal) compass -
    Emissivity correction Yes
    Transmission correction -
    Background (reflected) compensation Yes
    Voice annotation (audio) -
    Multi-mode video output -
    Multi-mode video recording (standard AVI with MPEG encoding) -
    Multi-mode video recording (radiometric .IS3) -
    Memory review Thumbnail review
    Battery (field-replaceable, rechargeable) One
    Battery life 4+ hours (each)*
    External battery charging base Optional (accessory)
    Charging power supply Yes
    Drop test 2 meter (6.5 feet)
    Ingress protection (IP) rating (IEC 60529) IP 54
    Recommended calibration cycle Two-years
    Multifunction card reader -
    Memory storage 2 GB SD memory card
    Direct download capability Mini USB download direct to PC
    Operating temperature range -10°C to +50°C (14°F to 122°F)
    Storage temperature range -20°C to +50°C (-4°F to 122°F)
    Operating humidity Operating and storage 10% to 95%, non-condensing
    Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
    Safety standards IEC 61010-1: Cat None, Pollution Degree 2
    C Tick IEC/EN 61326-1
    EMI, RFI, EMC EN61326-1; FCC Part 5
    User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
    Standard warranty period Two-years
    Extended warranty and service plans Yes
    *Assumes 50% brightness of LCD

    * For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ± ([% of Reading ] + [ Number of least significant digits ]).

    Fluke 3000 FC Series Wireless Multimeter

    AC Voltage
    Range¹ / resolution   600.0 mV / 0.1 mV
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy2 3 4 45 Hz to 500 Hz 1.0% + 3
    500 Hz to 1 kHz 2.0% + 3
    1. All AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    mV Range / resolution 600.0 mV / 0.1 mV
    Accuracy 0.09% + 2
    V Range / resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 0.09% + 2
    0.15% + 2
    ))) Range / resolution 600 Ω / 1 Ω
    Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω Range / resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    60.00 kΩ / 0.1 kΩ
    600.0 kΩ / 0.001 MΩ
    50.00 MΩ / 0.01 MΩ
    Accuracy 0.5% + 2
    0.5% + 1
    1.5% + 3
    Diode test Range / resolution 2.000 V / 0.001 V
    Accuracy 1% + 2
    µF
    Range / resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF1 / 1 μF
    Accuracy 1.2% + 2
    10% typical
    1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    mA AC
    (45 Hz to 1 kHz)
    Range1 / resolution 60.00 mA / 0.01 mA
    400.0 mA3/ 0.1 mA
    Accuracy 1.5% + 3
    mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
    400.0 mA3/ 0.1 mA
    Accuracy 0.5% + 3
    1. All AC current ranges are specified from 5% of range to 100% of range.
    2. Input burden voltage (typical): 400 mA input 2 mV/mA.
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range / resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 kHz
    99.99 kHz / 0.01 kHz
    Accuracy1 0.1% + 1
    1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Overload protection 1100 Vrms
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 120 dB at DC, 50 Hz or 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Overload protection 1100 Vrms
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 60 dB, DC to 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Overload protection 1100 Vrms
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 120 dB at DC, 50 Hz or 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Open Circuit Test Voltage
    Overload protection 1100 Vrms
    Input impedance (nominal) < 2.7 VDC
    Full scale voltage to 6 MΩ
    Full scale voltage 50 MΩ
    < 0.7 VDC
    < 0.9 VDC
    Typical short circuit current < 350 mA
    Overload protection 1100 Vrms
    Input impedance (nominal) < 2.7 VDC
    Full scale voltage to 6 MΩ
    Full scale voltage 50 MΩ
    2.000 VDC
    Typical short circuit current < 1.1 mA
    mA Function
    Overload protection Fused, 44/100 A, 1000 V FAST Fuse
    Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording Accuracy
    DC functions ±12 counts for changes > 350 mS in duration.
    AC functions ±40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate 4/sec
    Volts, amps, ohms 6000 counts
    Frequency 10,000 counts
    Capacitance 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20m
    Obstructed, sheetrock wall Up to 6.5m
    Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m
    Temperature Operating -10°C to 50°C
    Storage -40°C to 60°C
    Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Relative humidity 0% to 90% (0°C to 35°C)
    0% to 75% (35°C to 40°C)
    0% to 45% (40°C to 50°C)
    Altitude Operating 2,000 m
    Storage 12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008
    FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    UL 61010-1: 3rd edition
    IEC/EN 61010-1:2010
    Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    Weight 340 g (12 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools

    Fluke a3001 FC Wireless iFlex AC Current Module

    Specifications
    Range 0.5 A to 2500 A AC
    Resolution 0.1 A
    Accuracy 3% ± 5 digits (5 Hz to 500 Hz)
    Crest factor (50 Hz / 60 Hz) 3.0 at 1100 A
    2.5 at 1400 A
    1.42 at 2500 A
    Add 2% for C.F. > 2
    LCD w/backlight 3½ digits
    Log rate/interval 1 sec minimum/adjustable by PC or front panel
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Operating humidity 90% at 35°C
    75% at 40°C
    45% at 50°C
    Altitude Operating 2,000 m
    Storage 12,000 m
    EMC EN 61326-1:2006
    Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Pollution Degree 2
    Jaw opening 25.4 cm (10 in) coil
    Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
    Weight .22 kg (8 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools
    • Models
      Model Name Description  
      FLK-Ti105 30HZ/FCA KIT Fluke Ti105 a3001 FC iFlex® Kit
       

      Includes:

      Fluke 105 Infrared Camera

      • AC power adapter
      • Lithium ion smart battery (1)
      • USB cable
      • SD memory card
      • Fluke Connect™ WiFi SD Card
      • Hard carrying case
      • Soft transport bag
      • Adjustable hand strap (left- or right-handed use)
      • Printed users' manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD
      • SmartView® software
      • Warranty registration card

      Fluke 3000 FC Wireless Digital Multimeter with three (3) AA batteries (installed)

      • One (1) a3001 FC Module with two (2) AA batteries (installed)
      • One (1) iFlex 10" coil
      • One (1) magnet/strap
      • TL175 Test Leads (1 pair)
      • AC175 Alligator Clips (1 pair)
      • C3003 3-compartment soft case
      • Information pack
    • Batteries, Chargers & Adapters
      Model Name Description  
      Fluke TI Car Fluke Infrared Camera Car Charger
    • CarePlans
      Model Name Description  
      Fluke Infrared Camera Products Fluke Infrared Camera Products CarePlans Fluke Store
    • Wireless Accessories
      Model Name Description  
      FLK-FC-SD CARD Fluke Connect Wireless SD Card
    • Related Products
      Model Name Description  
      FLK-A3004 FC Fluke a3004 FC Wireless 4-20 mA DC Clamp Meter
      FLK-A3003 FC Fluke a3003 FC Wireless 2000 A DC Current Clamp Meter
      FLK-Ti400 Fluke Ti400 Infrared Camera
      FLK-Ti200 Fluke Ti200 Infrared Camera
      FLK-Ti300 Fluke Ti300 Infrared Camera
      FLK-3000 FC Fluke 3000 FC Series Wireless Multimeter
      FLK-A3000 FC Fluke a3000 FC Wireless AC Current Clamp Module
      FLK-A3001 FC Fluke a3001 FC Wireless iFlex® AC Current Module
      FLK-A3002 FC Fluke a3002 FC Wireless AC/DC Current Module
      FLK-3000 FC GM Fluke 3000 FC General Maintenance System
      FLK-3000 FC HVAC Fluke 3000 FC HVAC System
      FLK-3000 FC IND Fluke 3000 FC Industrial System
      FLK-A3000 FC Kit Fluke a3000 FC Wireless AC Current Clamp Kit
      FLK-A3001 FC Kit Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
      FLK-T3000 FC Fluke t3000 FC Wireless Temperature Module
      FLK-V3000 FC Fluke v3000 FC Wireless AC Voltage Module
      FLK-V3000 FC Kit Fluke v3000 FC Wireless AC Voltage Kit
      FLK-V3001 FC Fluke v3001 FC Wireless DC Voltage Module
      FLK-T3000 FC Kit Fluke t3000 FC Wireless Temperature Kit
      FLK-V3001 FC Kit Fluke v3001 FC Wireless DC Voltage Kit
      FLK-V3003 FC Kit Fluke v3003 FC Wireless AC-DC Voltage Measurement Kit
      Fluke-789 FC/t3000 Fluke 789 FC ProcessMeterTM and Temperature Kit
      Fluke 287 Kit Fluke 287 FlukeView® Forms Combo Kit
      Fluke 289 Fluke 289 True-RMS Industrial Logging Multimeter
      Fluke 289 Kit Fluke 289 FlukeView® Forms Combo Kit
      FLK-FC-SD CARD Fluke Connect Wireless SD Card
      FLK-Ti95 9HZ/FCA Ti95 Fluke Connect FCA Kit
      Fluke 287 Fluke 287 True-RMS Electronics Logging Multimeter
      FLK-Ti90 Fluke Ti90 Infrared Camera
      FLK-Ti95 Fluke Ti95 Infrared Camera
      FLK-Ti95 9HZ/FCC Ti95 Fluke Connect FCC Kit
      FLK-Ti100 Fluke Ti100 General Use Infrared Camera
      FLK-Ti105 Fluke Ti105 Infrared Camera for Industrial and Commercial Applications
      FLK-Ti110 Fluke Ti110 Infrared Camera for Industrial and Commercial Applications
      FLK-Ti125 Fluke Ti125 Industrial-Commercial Infrared Camera
      FLK-TiR105 Fluke TiR105 Infrared Camera
      FLK-TiR110 Fluke TiR110 Building Diagnostic Infrared Camera
      FLK-TiR125 Fluke TiR125 Infrared Camera
      FLK-Ti200/FCA KIT Fluke Ti200 a3001 FC iFlex® Kit
      FLK-Ti300/FCA Kit Fluke Ti300 a3001 FC iFlex® Kit
      FLK-Ti400/FCA Kit Fluke Ti400 a3001 FC iFlex® Kit
      FLUKE-IR3000FC Fluke ir3000 FC Connector
      C3004IND Fluke C3004 Soft Case for FC Industrial System
      FLK-pc3000 FC Fluke pc3000 FC Wireless PC Adapter
    • Manuals
      Title  
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti100, Ti110, Ti125, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual Supplement Download
      Fluke Connect Wi-Fi to Thermal Imager Quick Reference Guide Download
      Ti100 Ti105, Ti110, Ti125, TiR100, TiR105, TiR110, TiR125 CE Declaration of Conformity Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti105, Ti100, Ti110, Ti125, TiR110, TiR125 Statement of Memory Volatility Download
    • Application Notes
      Title  
      6 tips to cut industrial and commercial energy costs Download
      ABCs of DMMs: Multimeter features and functions explained Download
      Fluke Connect™ ABCs of DMMs Download
      Implementing an infrared thermography maintenance program Download
      Implementing an infrared thermography program Download
      Measuring three phase load draw with Fluke Connect® wireless tools Download
      Phase-to-phase troubleshooting with Fluke Connect® wireless tools Download
      Testing production controls with Fluke Connect® wireless tools Download
      Testing production line equipment with Fluke Connect® wireless tools Download
      Three-phase unbalance testing with Fluke Connect® wireless tools Download
      Top 5 places to look for energy losses in commercial buildings Download
      Top 6 places to look for energy losses in commercial buildings Download
    • Brochures
      Title  
      7 Reasons to connect your tools Download
      Fluke Connect® Brochure Download
      Fluke Connect® compatibility chart Download
    • Data Sheets
      Title  
      Fluke 3000 FC Series Test Tools Download
      SmartView Software Data Sheet Download
      TI Performance Series Data Sheet Download

Fluke Connect is not available in all countries.

©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

×
×
×