Keeping your world up and running.®

T6-1000 Electrical Tester

Now you can measure voltage without test leads. Be safer, faster, more efficient. And be everywhere, testing where it used to be impossible

T6-1000
  • T6-1000
  • T6-1000
  • T6-1000
  • T6-1000
Overview
Features
Reviews
Specs
Models
Resources
  • Measure voltage … without test leads

    FieldSense technology lets you slide the open fork over a conductor and see the voltage level.1

    • Be safer: Measure voltage to 1000 V ac through the open fork, without test leads.
    • Be faster: No need to open covers or remove wire nuts.
    • Be more efficient: Simultaneously measure voltage and current.
    • Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).

    Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage.+ Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A. It will change your job. Safer. Faster. Easier.

    1 Requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
    FieldSense capable Measures Volts & Amps No Contact Needed True RMS readingCE Certified CSA Certified CTick Certified
  • Product Highlights

    • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage+
    • Simultaneous voltage and current display – shows all power supply measurements at a glance for efficient trouble shooting
    • 1 to 1000 V ac or dc (T6-1000)
    • 0.1 to 200 A ac
    • True-rms voltage and current
    • Resistance 1 Ω to 100 kΩ
    • Frequency measurement 45 Hz to 66 Hz
    • Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
    • HOLD button temporarily freezes the reading for easy viewing
    • Easy to read display with backlight
    • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
    • Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase*
    + Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations. * Register product online within 45 days of purchase to extend warranty to four years. See http://a.fluke.com/registration for details. Two-year additional warranty offer may be discontinued without notice
  • Measurement Specifications
    Function Requires test leads Range Resolution Accuracy[1]
    FieldSense
    ac voltage true-rms
    No 1000 V 1 V ± (3 % + 3 counts) 45 Hz - 66 Hz[2][3]
    FieldSense
    ac current true-rms
    No 200.0 A 0.1 A ± (3% + 3 counts) 45 Hz - 66 Hz
    FieldSense
    frequency (Hz)
    No 45 Hz – 66 Hz 1 Hz ± (1% + 2 counts)[3]
    Volts ac true-rms Yes 1000 V 1 V ± (1.5% + 2 counts) 45 Hz - 66 Hz
    Volts dc Yes 1000 V 1 V ± (1% + 2 counts)
    Resistance Yes 2000 Ω 1 Ω ± (1% + 2 counts)
    Yes 20.00 kΩ 0.01 kΩ
    Yes 100.0 kΩ 0.1 kΩ
    Safety   1000 V CAT III
    600 V CAT IV
       

    Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
    Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
    Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.


    General Specifications
    Calibration 1-year calibration cycle
    Dimensions 61.1 x 259.3 x 43.8 mm
    Jaw opening 17.8 mm
    Weight 0.35 kg (0.78 lb)
    Temperature Operating -10 °C to +50 °C (14 °F to 122 °F)
    Storage -30 °C to +60 °C (-22 °F to +140 °F)
    Altitude Operating 2,000 m (6,562 feet)
    Storage 10,000 m (32,808 feet)
    Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
    0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
    0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
    Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
    Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
    0.1 x (specified accuracy) / °C for <18°C or >28 °C
    Safety IEC/EN 61010-1: Pollution Degree 2
    Electromagnetic Environment IEC/EN 61326-1: Portable
    • Models
      Model Name Description  
      T6-1000 T6-1000 Electrical Tester
       

      Includes:

      • Attached test leads with removable 4 mm probe caps
      • User documentation
    • Manuals
      Title  
      T6-600, T6-1000 Statement of Memory Volatility Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
    • Application Notes
      Title  
      Fluke FieldSense Technology Download
      How to use Fluke T6 Electrical Testers Download
    • Data Sheets
      Title  
      T6 Electrical Testers with FieldSense Download
×
×