Keeping your world up and running.®

T6-1000 Electrical Tester

Now you can measure voltage without test leads. Be safer, faster, more efficient. And be everywhere, testing where it used to be impossible

  • T6-1000
  • T6-1000
Overview
Features
Reviews
Specs
Models
Resources
  • Measure voltage … without test leads

    We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.*

    See how easy it is to make FieldSense measurements

    Play Video

     

    FieldSense tools

    Learn how to use the T6
    Download the Quick Reference Guide

    FieldSense tools

    T6 Electrical Tester Helps Team at Cutting Edge Cancer Research Center

    Play Video

     

    T6 Awards

    2017 NECA Showstopper H18 Innovation Awards Winner

    Why use the T6 Electrical Tester?

    Electricians often work in boxes jammed with wires, where finding a safe metallic contact point can be a challenge. With the T6-600 or T6-1000 you take measurements by sliding a single wire into the open fork.

    How FieldSense Works

    FieldSense technology is truly a breakthrough in how voltage is measured. While other open fork testers detect a magnetic field to show ac current, FieldSense technology detects an electrical field. This field interacts with a reference signal created by the T6 tester, creating a voltage value on the tester’s display.

    Who needs a T6 tester?

    Commercial and light industrial electricians can use T6 Electrical Testers for most everyday measurements. These devices easily fit in your pocket, making them easy to access on the front-line for electricians of all industries.

    * Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
  • FieldSense capable Measures Volts & Amps No Contact Needed True RMS readingCE Certified CSA Certified CTick Certified

    5 reasons the T6 belongs in your toolbelt

    1. Be safer: Measure voltage to 1000 V ac through the open fork, without test leads.
    2. Be faster: No need to open covers or remove wire nuts.
    3. Be more efficient: Simultaneously measure voltage and current.
    4. Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).
    5. Go beyond simple detection. Actually measure ac voltage and current values without test leads.

     

    Product Highlights

    • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage*
    • Simultaneous voltage and current display – shows all power supply measurements at a glance for efficient trouble shooting
    • 1 to 1000 V ac or dc (T6-1000)
    • 0 to 200 A ac
    • True-rms voltage and current
    • Resistance 1 Ω to 100 kΩ
    • Frequency measurement 45 Hz to 66 Hz
    • Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
    • HOLD button temporarily freezes the reading for easy viewing
    • Easy to read display with backlight
    • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
    • Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase+

    Tips: FieldSense Technology

    Do not hold or touch wire you are testing during a measurement. Use the black probe to make the ground connection if:
    • wearing gloves or insulated footwear
    • standing on an insulated ladder
    • additional ground contact is required for the application

    FieldSense measurement looks like this when properly grounded:

    Correct Display
    • Display color turns green
    • Display shows a valid measurement >16 V rather than dashes or 0.0
    • shows for measurement ≥30 V
    * Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
    + Register product online within 45 days of purchase to extend warranty to four years. See http://a.fluke.com/registration for details. Two-year additional warranty offer may be discontinued without notice
  • Measurement Specifications
    Function Requires test leads Range Resolution Accuracy[1]
    FieldSense
    ac voltage true-rms
    No 1000 V 1 V ± (3 % + 3 counts) 45 Hz - 66 Hz[2][3]
    FieldSense
    ac current true-rms
    No 200.0 A 0.1 A ± (3% + 3 counts) 45 Hz - 66 Hz
    FieldSense
    frequency (Hz)
    No 45 Hz – 66 Hz 1 Hz ± (1% + 2 counts)[3]
    Volts ac true-rms Yes 1000 V 1 V ± (1.5% + 2 counts) 45 Hz - 66 Hz
    Volts dc Yes 1000 V 1 V ± (1% + 2 counts)
    Resistance Yes 2000 Ω 1 Ω ± (1% + 2 counts)
    Yes 20.00 kΩ 0.01 kΩ
    Yes 100.0 kΩ 0.1 kΩ
    Safety   1000 V CAT III
    600 V CAT IV
       

    Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
    Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
    Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.


    General Specifications
    Calibration 1-year calibration cycle
    Dimensions 61.1 x 259.3 x 43.8 mm
    Jaw opening 17.8 mm
    Weight 0.35 kg (0.78 lb)
    Temperature Operating -10 °C to +50 °C (14 °F to 122 °F)
    Storage -30 °C to +60 °C (-22 °F to +140 °F)
    Altitude Operating 2,000 m (6,562 feet)
    Storage 10,000 m (32,808 feet)
    Relative Humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
    0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
    0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
    Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
    Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C
    0.1 x (specified accuracy) / °C for <18°C or >28 °C
    Safety IEC/EN 61010-1: Pollution Degree 2
    Electromagnetic Environment IEC/EN 61326-1: Portable
    • Models
      Model Name Description  
      T6-1000 T6-1000 Electrical Tester
       

      Includes:

      • Attached test leads with removable 4 mm probe caps
      • User documentation
    • Manuals
      Title  
      T6-1000/T6-600 Service Information Download
      T6-600, T6-1000 Statement of Memory Volatility Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Quick Reference Guide Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
      T6-600/T6-1000 Safety Sheet Download
    • Application Notes
      Title  
      5 ways FieldSense can help you work safer Download
      Fluke FieldSense Technology Download
      How to use Fluke T6 Electrical Testers Download
    • Data Sheets
      Title  
      T6 Electrical Testers with FieldSense Download
×
×
×