Keeping your world up and running.®

Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)

The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)
Overview
Features
Specs
Models
Accessories
Resources
  • The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

    • Three ranges
      • 30 A
      • 300 A
      • 3000 A, 1, 10 or 100 mV/A output
    • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
    • Maximum conductor diameter 178 mm (7 in.)
    • CAT III 600 V safety rating

    Also available in pack of 4 for use in Power Quality Analyzers. Click here for more info.

  • Electrical Specification
    Current ranges 30 A
    300 A
    3000 A
    AC rms
    Output sensitivity (AC-coupled) 100 mV
    10 mV
    1mV per A
    Load impedance 100 kΩ minimum
    Accuracy at +25°C: ±1% of range (45 Hz to 65 Hz)
    Linearity 10% to 100% of range: ±0.2% of reading
    Noise 8 mV AC rms (30 A)
    2 mV AC rms (300 A, 3000 A)
    Frequency range 10 Hz to 50 kHz (-3 dB)
    Phase error < ±1° (45 Hz to 65 Hz)
    ±10° (at 20 kHz)
    Position sensitivity with cable > 25 mm from the coupling: ±2% of range
    External field with cable > 200 mm from the head: ±1% of range
    Power supply 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator or dedicated external power supply
    Temperature coefficient ±0.08% of reading per °C
    Working voltage see Safety standards section: 600 V AC rms or DC
    General Specifications
    Head circumference 915 mm (36 in.)
    Head cable diameter 14.3 mm (0.56 in)
    Head bend radius 38.1 mm (1.5 in)
    Cable length (head to electronics) 2 m (6.56 ft)
    Output connection 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter
    Operating temperature range -20°C to +90°C (-4°F to 190°F) (head)
    -20°C to +85°C (-4°F to 185°F) (electronics)
    Storage temperature range -40°C to +105°C (-40°F to 221°F) (head)
    -20°C to +85°C (-4°F to 185°F) (electronics)
    Operating humidity 15% to 85% (non-condensing)
    Weight 180 g (0.396 lb) (head)
    190 g (0.419 lb) (electronics)
    Safety standards BS EN 61010-1: 2001
    BS EN 61010-2-032: 2002
    BS EN 61010-031: 2002
    600 Vrms, Category III, Pollution Degree 2
    Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz
    EMC standards EN 61326: 1998 +A1, A2, and A3
    Maximum conductor size 610 mm or 914 mm, depending on model
    • Model
      Model Name Description  
      Fluke i3000s Flex 36 Fluke i3000s Flex-36 AC Current Clamp, 915 mm (36 in.)
      AC Current Clamp, 915 mm (36 in.)
    • Compatible Products
      Model Name Description  
      Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
      Fluke 123 Fluke 123 Industrial ScopeMeter® Hand Held Oscilloscope
      Fluke 123/S Fluke 123/S Industrial ScopeMeter® Hand Held Oscilloscope
      Fluke 124 Fluke 124 Industrial ScopeMeter® Hand Held Oscilloscope
      Fluke 124/S Fluke 124/S Industrial ScopeMeter® Hand Held Oscilloscopes with SCC120 kit
      Fluke 125 Fluke 125 ScopeMeter® Oscilloscopes
      Fluke 125/S Fluke 125/S ScopeMeter® Oscilloscopes with SCC120 kit
    • Manuals
      Title  
      TPS Flex, i310 Flex, i331x Flex, i1730 Flex, i17XX Flex, i430 Flex, I2500 Flex CE Declaration of Conformity Download
      TPS Flex, i310 Flex, i331x Flex, i1730 Flex, i17XX Flex, i430 Flex, I2500 Flex CE Declaration of Conformity Download