Keeping your world up and running.®

Fluke 572-2 High-Temperature Infrared Thermometer

Fluke-572-2 High Temperature Infrared Thermometer offers the highest temperature range up to 900°C with highest distance to spot of 60:1

Overview
Features
Reviews
Specs
Models
Accessories
Resources
  • The Fluke 572-2 High-Temperature Infrared Thermometer is the best product you can use in high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical environments, the new 572-2 allows you to carry the most trusted name in test tools any place where you need accurate, high-temperature and high distance-to-spot measurements.

    With a straight-forward user interface and soft-key menus, the Fluke 572-2 makes even complex measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.

    • Measure -30°C to 900°C (-22°F to 1652°F)
    • 60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
    • Multi-language interface (user select)
    • Current Temperature plus MAX, MIN, DIF, AVG temperature displays
    • Compatible with standard mini-connector K-type thermocouples, including ones you already own and have installed
    • Adjustable emissivity and predefined emissivity table
    • Infrared and thermocouple temperature on backlit display
    • Last reading Hold (20 seconds)
    • High and low temperature alarm
    • Data storage and review (99 data sets)
  • Infrared Measurements
    Infrared temperature range -30°C to 900°C (-22°F to 1652°F)
    IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
    ≥ -10°C to < 0°C: ±2°C
    < -10°C: ±3°C
    ≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
    ≥ 14°F to < 32°F: ±4°F
    < 14°F: ±6°F
    IR repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
    Display resolution 0.1°C / 0.1°F
    Distance: Spot 60:1 (calculated at 90% energy)
    Minimum spot size 19 mm
    Laser sighting Offset dual laser, output < 1 mW
    Spectral response 8 μm to 14 μm
    Response time (95%) < 500 ms
    Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
    Contact Measurements
    K-type thermocouple input temperature range -270°C to 1372°C (-454°F to 2501°F)
    K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) < -40°C: ±(1°C + 0.2° / 1°C)
    ≥ -40°C: ±1% or 1°C, whichever is greater
    < -40°F: ±(2°F + 0.2° / 1°F)
    ≥ -40°F: ±1% or 2°F, whichever is greater
    K-type thermocouple 0.1°C / 0.1°F
    K-type thermocouple repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
    Measurement Options
    Hi/Low alarms Audible and two-color visual
    Min/Max/Avg/Dif Yes
    Switchable celsius and fahrenheit Yes
    Backlight Two levels, normal and extra bright for darker environments
    Probe input K-type thermocouple simultaneous display of probe and IR temperature
    Trigger lock Yes
    Data storage 99 points
    Display Dot matrix 98 x 96 pixels with function menus
    Communication USB 2.0
    K-Type Thermocouple Specifications
    Measurement range (bead probe) -40°C to 260°C (-40°F to 500°F)
    Accuracy ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
    Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
    General Specifications
    Safety and compliance IEC 60825-1
    FDA Laser Class II
    IEC 61326-1
    CE Complaint
    CMC # 01120009
    Operating temperature 0°C to 50°C (32°F to 122°F)
    Storage temperature -20°C to 60°C (-4°F to 140°F)
    Relative humidity 10% to 90% RH non-condensing up to 30°C (86°F)
    Operating altitude 2000 meters above mean sea level
    Weight 0.322 kg (0.7099 lb)
    Power 2 AA batteries
    Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)
    • Models
      Model Name Description  
      Fluke 572-2 Fluke 572-2 High-Temperature Infrared Thermometer
       

      Includes:

      • K-type thermocouple bead probe
      • Durable hard case
      • USB 2.0 computer interface cable
×