Fluke 750 Series Documenting Process Calibrator and 154 HART Calibration Assistant Bundle with Rugged Case

HART Calibration assistance at your fingertips Combine a Fluke 750 series calibrator with the Fluke 154 HART Calibration assistant for a total HART calibration solution.

Fluke 750 Series and 154 HART Calibration Assistant
  • Fluke 750 Series and 154 HART Calibration Assistant
  • Fluke 750 Series and 154 HART Calibration Assistant
  • Fluke 750 Series and 154 HART Calibration Assistant
Overview
Features
Specs
Models
Resources
  • HART Calibration assistance at your fingertips

    Combine a Fluke 750 series calibrator with the Fluke 154 HART Calibration assistant for a total HART calibration solution.

    The 754 and 753 are powerful multifunction documenting calibrators that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. The 754 also features a powerful built in HART® interface capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.

    The Fluke 154 HART Calibration Assistant is a standalone tablet based HART® communication tool. The tablet, configured with the “FlukeHART mobile app, utilizes a wireless HART modem that connects directly to the HART transmitter being tested or configured. When you combine your Fluke 154 HART Calibration Assistant with a Fluke 750 Series Documenting Process Calibrator you have a complete HART calibration and configuration solution.

  • 75X Key Features

    • Complete documenting multifunction calibrator: Communicate with the most popular HART devices (754)
    • Rugged robust electrical and mechanical design:
      • CAT II 300 V rating vs CAT I 30 V for most other DPCs
      • Withstand accidental exposure to 120-240 V ac, V dc
      • 3-year warranty
    • Compatible with DPCTrack2 Calibration Management Software: Add DPCTrack2 for a complete documenting calibration solution
    • Measure and source volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
      • Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
      • Power transmitters during test using loop supply with simultaneous mA measurement
      • Measure/source pressure using any of 50 Fluke 750Pxx Pressure Modules
      • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations.
    • Record and document results
      • Holds up to a full week of downloaded procedures and calibration results.
      • Use many features like autostep, custom units, user entered values
      • Test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay

    154 Key Features

    • Full HART communication capability: Communicate with and configure any HART device
    • Full HART Device Description (DD) support with free updates: Quarterly updates available via free download for 3-years
    • Wireless HART Modem: Communicate from tablet PC to connected HART device for ease of use and safety, up to 250 ft
    • Easy connect with Wireless HART Modem: Includes configurable connection cable that accepts either the hook clips for connecting to wires or the extended tooth alligator clips designed to connect to transmitter connection screw heads. Rechargeable lithium-ion battery lasts easily for several days of HART device configuration and testing activities. Rugged enclosure and test lead set designed for process environments.
    • HART support: Complete access to all features of the HART device’s DD including methods.
    • Download free DD updates: Free updates for 3-years. Updates available when DD updates released from the HART FieldComm group (approximately four times a year).
    • Hard side case: Protects and stores tablet, modem, test leads and connection cable in a lightweight durable tote that is easy to carry.
    • Select from multiple languages: Select language from the Android operating system. HART communication commands are limited to English per the HARTdevice descriptions.
    • Store device configurations: Store HART device configurations in ASCII or PDF file configurations.
    • Meets HART physical layer specification
      • HCF_SPEC-54
      • DD updates
  • Fluke 154 HART Calibration Assistant
    Tablet
    Operating system Android 5.0 or newer
    Processor ARM or Atom
    Memory RAM 1 GB
    Memory ROM 2 GB
    Screen 960x540 qHD
    Communication port Bluetooth

    HART Modem
    Enclosure
    Material High strength ABS Plastic
    Dimensions 10.16 x 2.5 x 6.9 cm (4 x 1 x 2.75 in)
    Total unit weight 0.16 kg (0.36 lbs)
    Cables
    HART cable length 4 ft (1.2 m)
    HART cable connectors Mini-Grabber
    HART Interface
    Interface Capacitive coupling
    Output 600 mVpp
    Leakage < 10 uA
    Connections Across loop resistor or HART field device
    Specifications HART 4, HART 5, HART 6, HART 7
    HART physical layer spec HCF_SPEC-54
    Bluetooth
    Specification Bluetooth v2.0
    Frequency 2.4 GHz
    Class 1 master distance 275 ft (83.8 m)
    Battery
    Type Rechargeable Li-Ion
    Life 19 hours continuous use
    Environmental
    Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
    Storage temperature -10 °C to 45 °C (-14 °F to 113 °F)
    Humidity 0% to 90% (non-condensing)

    Measurement Accuracy
    Voltage DC Resolution 1 Year 2 Years
    100.000 mV 0.02% + 0.005 mV 0.03% + 0.005 mV
    3.00000 V 0.02% + 0.00005 V 0.03% + 0.00005 V
    30.0000 V 0.02% + 0.0005 V 0.03% + 0.0005 V
    300.00 V 0.05% + 0.05 V 0.07% + 0.05 V
    Voltage AC Range
    40 to 500 Hz
    Resolution 1 Year 2 Years
    3.000 V 0.001 V 0.5% + 0.002 V 1.0% + 0.004 V
    30.00 V 0.01 V 0.5% + 0.02 V 1.0% + 0.04 V
    300.0 V 0.1 V 0.5% + 0.2 V 1.0% + 0.2 V
    Current DC 30.000 mA 0.01% + 5 uA 0.015% + 7 uA
    110.00 mA 0.01% + 20 uA 0.015% + 30 uA
    Resistance 10.000 Ω 0.05% + 50 mΩ 0.07% + 70 mΩ
    100.00 Ω 0.05% + 50 mΩ 0.07% + 70 mΩ
    1.0000 kΩ 0.05% + 500 mΩ 0.07% + 0.5 Ω
    10.000 kΩ 0.1% + 10 Ω 0.15% + 15 Ω
    Resolution Accuracy(2 years)
    Frequency 1.00 to 110.00 Hz 0.01 Hz 0.05 Hz
    110.1 to 1100.0 Hz 0.1 Hz 0.5 Hz
    1.101 to 11.000 kHz 0.001 kHz 0.005 kHz
    11.01 to 50.00 kHz 0.01 kHz 0.05 kHz
    Source Accuracy
    1 Year 2 Years
    Voltage DC 100.000 mV 0.01% + 0.005 mV 0.015% + 0.005 mV
    1.00000 V 0.01% + 0.00005 V 0.015% + 0.0005 V
    15.0000 V 0.01% + 0.0005 V 0.015% + 0.0005 V
    Current DC 22.000 mA (source) 0.01% + 0.003 mA 0.02% + 0.003 mA
    Current sink (simulate) 0.02% + 0.007 mA 0.04% + 0.007 mA
    Resistance 10.000 Ω 0.01% + 10 mΩ 0.015% + 15 mΩ
    100.00 Ω 0.01% + 20 mΩ 0.015% + 30 mΩ
    1.0000 kΩ 0.02% + 0.2 Ω 0.03% + 0.3 Ω
    10.000 kΩ 0.02% + 3 Ω 0.03% + 5 Ω
    2 Years
    Frequency 0.1 to 10.99 Hz 0.01 Hz
    0.01 to 10.99 Hz 0.01 Hz
    11.00 to 109.99 Hz 0.1 Hz
    110.0 to 1099.9 Hz 0.1 Hz
    1.100 to 21.999 kHz 0.002 kHz
    22.000 to 50.000 kHz 0.005 kHz
    Technical Data
    Data log Functions Measure Functions Voltage, current, resistance, frequency, temperature, pressure
    Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute
    Maximum record length 8000 readings (7980 for 30 or 60 readings/minute)
    Ramp Functions Source Functions Voltage, current, resistance, frequency, temperature
    Rate 4 steps/second
    Trip detect Continuity or voltage (continuity detection not available when sourcing current)
    Loop power function Voltage Selectable, 26 V
    Accuracy 10%, 18 V minimum at 22 mA
    Maximum current 25 mA, short circuit protected
    Maximum input voltage 50 V DC
    Step functions Source functions Voltage, current, resistance, frequency, temperature
    Manual step Selectable step, change with arrow buttons
    Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat
    Environmental Specifications
    Operating Temperature -10°C to +50°C
    Storage Temperature -20°C to +60°C
    Dust/water resistance Meets IP52, IEC 529
    Operating Altitude 3000 m above mean sea level (9842 ft)
    Safety Specifications
    Agency Approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
    Mechanical and General Specifications
    Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in)
    Weight 1.2 kg (2.7 lb)
    Batteries Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh
    Battery Life >8 hours typical
    Battery Replacement Replace without opening calibrator; no tools required
    Side port connections Pressure module connector
    USB Connector to interface to your PC
    Digital instrument (HART) connector
    Connection for optional battery charger/eliminator
    Data storage capacity 1 week of calibration procedures results
    90 day specifications The standard specification interval for the 750 Seriesare 1 and 2 years.
    Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2.
    Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant.
    Temperature, Resistance Temperature Detectors
    Degrees or % of reading
    Type (α) Range °C Measure °C1
    1 year 2 year
    100 Ω Pt (385) -200 to 100
    100 to 800
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    200 Ω Pt (385) -200 to 100
    100 to 630
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    500 Ω Pt (385) -200 to 100
    100 to 630
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    1000 Ω Pt (385) -200 to 100
    100 to 630
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    100 Ω Pt (3916) -200 to 100
    100 to 630
    0.07°C
    0.02% + 0.05°C
    0.14°C
    0.04% + 0.10°C
    100 Ω Pt (3926) -200 to 100
    100 to 630
    0.08°C
    0.02% + 0.06°C
    0.16°C
    0.04% + 0.12°C
    10 Ω Cu (427) -100 to 260 0.2°C 0.4°C
    120 Ω Ni (672) -80 to 260 0.1°C 0.2°C
    Source current Source °C Allowable current2
    1 year 2 year
    1 mA 0.05°C
    0.0125% + 0.04°C
    0.10°C
    0.025% + 0.08°C
    0.1 mA to 10 mA
    500 μA 0.06°C
    0.017% + 0.05°C
    0.12°C
    0.034% + 0.10°C
    0.1 mA to 1 mA
    250 μA 0.06°C
    0.017% + 0.05°C
    0.12°C
    0.034% + 0.10°C
    0.1 mA to 1 mA
    150 μA 0.06 C
    0.017% + 0.05°C
    0.12 C
    0.034% + 0.10°C
    0.1 mA to 1 mA
    1 mA 0.05°C
    0.0125% + 0.04°C
    0.10°C
    0.025% + 0.08°C
    0.1 mA to 10 mA
    1 mA 0.05°C
    0.0125% + 0.04°C
    0.10°C
    0.025% + 0.08°C
    0.1 mA to 10 mA
    3 mA 0.2°C 0.4°C 0.1 mA to 10 mA
    1 mA 0.04°C 0.08°C 0.1 mA to 10 mA
    1. For two and three-wire RTD measurements, add 0.4°C to the specifications.
    2. Supports pulsed transmitters and PLCs with pulse times as short as 1 ms
    Temperature, Thermocouples
    Type Source °C Measure °C Source °C
    1 year 2 years 1 year 2 years
    E -250 to -200 1.3 2.0 0.6 0.9
    -200 to -100 0.5 0.8 0.3 0.4
    -100 to 600 0.3 0.4 0.3 0.4
    600 to 1000 0.4 0.6 0.2 0.3
    N -200 to -100 1.0 1.5 0.6 0.9
    -100 to 900 0.5 0.8 0.5 0.8
    900 to 1300 0.6 0.9 0.3 0.4
    J -210 to -100 0.6 0.9 0.3 0.4
    -100 to 800 0.3 0.4 0.2 0.3
    800 to 1200 0.5 0.8 0.3 0.3
    K -200 to -100 0.7 1.0 0.4 0.6
    -100 to 400 0.3 0.4 0.3 0.4
    400 to 1200 0.5 0.8 0.3 0.4
    1200 to 1372 0.7 1.0 0.3 0.4
    T -250 to -200 1.7 2.5 0.9 1.4
    -200 to 0 0.6 0.9 0.4 0.6
    0 to 400 0.3 0.4 0.3 0.4
    B 600 to 800 1.3 2.0 1.0 1.5
    800 to 1000 1.0 1.5 0.8 1.2
    1000 to 1820 0.9 1.3 0.8 1.2
    R -20 to 0 2.3 2.8 1.2 1.8
    0 to 100 1.5 2.2 1.1 1.7
    100 to 1767 1.0 1.5 0.9 1.4
    S -20 to 0 2.3 2.8 1.2 1.8
    0 to 200 1.5 2.1 1.1 1.7
    200 to 1400 0.9 1.4 0.9 1.4
    1400 to 1767 1.1 1.7 1.0 1.5
    C 0 to 800 0.6 0.9 0.6 0.9
    800 to 1200 0.8 1.2 0.7 1.0
    1200 to 1800 1.1 1.6 0.9 1.4
    1800 to 2316 2.0 3.0 1.3 2.0
    L -200 to -100 0.6 0.9 0.3 0.4
    -100 to 800 0.3 0.4 0.2 0.3
    800 to 900 0.5 0.8 0.2 0.3
    U -200 to 0 0.6 0.9 0.4 0.6
    0 to 600 0.3 0.4 0.3 0.4
    BP 0 to 1000 1.0 1.5 0.4 0.6
    1000 to 2000 1.6 2.4 0.6 0.9
    2000 to 2500 2.0 3.0 0.8 1.2
    XK -200 to 300 0.2 0.3 0.2 0.5
    300 to 800 0.4 0.6 0.3 0.6
    • Models
      Model Name Description  
      FLUKE-753/154 BU Fluke 753 and 154 HART Bundle
       

      Fluke 154 HART Calibration Assistant, tablet, tablet charger and USB micro-cable, Fluke HART App. (installed), HART modem, USB mini-cable, proof of purchase for product activation, hook test clips, alligator clips, magnetic hanging strap, and case. Manual installed on tablet. Three-year warranty.

      Fluke-753 Documenting process Calibrator, three sets of stackable test leads, three sets of TP220 test probes with three sets of “extended tooth alligator clips, two sets AC280 hook clips, BP7240 Li-ion battery pack, BC7240 battery charger, C799 field soft case, USB communication cable, getting started guide, instruction manual on CDROM, traceable certificate of calibration, DPC/TRACK 2 sample software. Model Fluke-754 includes HART communication cable. Three-year warranty.

      FLUKE-754/154 BU Fluke 754 and 154 HART Bundle
       

      Fluke 154 HART Calibration Assistant, tablet, tablet charger and USB micro-cable, Fluke HART App. (installed), HART modem, USB mini-cable, proof of purchase for product activation, hook test clips, alligator clips, magnetic hanging strap, and case. Manual installed on tablet. Three-year warranty.

      Fluke-754 Documenting process Calibrator, three sets of stackable test leads, three sets of TP220 test probes with three sets of “extended tooth alligator clips, two sets AC280 hook clips, BP7240 Li-ion battery pack, BC7240 battery charger, C799 field soft case, USB communication cable, getting started guide, instruction manual on CDROM, traceable certificate of calibration, DPC/TRACK 2 sample software. Model Fluke-754 includes HART communication cable. Three-year warranty.