Keeping your world up and running.®

Fluke Norma 4000 Power Analyzer

Fluke Norma Power Analyzer delivers precision measurements of 1 or 3 phase current and voltage, harmonics analysis, and Fast Fourier Transformation analysis.

Overview
Features
Specs
Models
Accessories
Resources
  • Reliable, highly accurate measurements for the test and development of power electronics.

    The compact Fluke Norma Power Analyzer 4000 provides the latest measurement technology to assist engineers with the development and testing of motors, inverters, lighting, power supplies, transformers and automotive components.

    Based on a patented, high-bandwidth architecture, the instrument delivers high-precision measurements of single or three-phase current and voltage, harmonics analysis, Fast Fourier Transformation (FFT) analysis, as well as calculations of power and other derived values.

    The Fluke Norma 4000 Three-Phase Power Analyzer is a rugged, high-precision analyzer providing unmatched price performance for easy and reliable use in the field, or as a bench unit in laboratories and on test benches.

    Applications

    • Electric motors and inverter drive systems – Through detailed spectrum analysis and dynamic torque calculation capabilities, switching losses caused by the inverter are accurately measured, and a thorough evaluation is made of torque transients and harmonics at higher frequencies.
    • Inverter drive system – Simultaneous measurement of all electrical and mechanical power parameters in the same time window enables users to observe the influence one component has on another, or on the whole system.
    • Lighting systems – A wide bandwidth of up to 10 MHz and a high sampling rate up to 1 MHz provide detailed signal analysis at ballast outputs. A unique shunt technique enables power measurements at very high frequencies. Simultaneous measurement of input and output power provides instant calculation of ballast losses.
    • Transformers – Synchronous six-phase power measurements enable highly accurate efficiency and loss calculations of large power transformers even at very low power factors. Synchronous multiphase resistance measurements of transformer coils are also possible.
    • Automotive – Synchronous electrical input and mechanical output measurements provide complete data on the efficiency and losses of individual components as well as the whole drive system.
  • Ideal for field testing, the Fluke Norma 4000 Three-Phase Power Analyzer offers easy and straight-forward operation with unmatched price performance. Features include: 1 to 3 power phases, 5.7 in / 144 mm color display, harmonic analysis, scope mode, vector diagram display, recorder function, Fluke NormaView PC software and expandable 4 MB RAM data memory.

    • Compact design makes it easy to carry and saves working space.
    • Simple user interface ensures easy, intuitive operation.
    • A variety of standard configurations allows users to choose the exact functionality required for their unique application.
    • Simultaneous parallel acquisition of all phases allows accurate viewing of dynamic events on all phases at exactly the same point in time.
    • All inputs are galvanically isolated to avoid short circuits in all applications.
    • Voltage, current and power harmonics measured up to the 40th harmonic for complete analysis.
    • FFT analysis, vector diagram, and Digital Oscilloscope (DSO) mode included in the base unit for complete analysis capability.
    • User-selectable average time – from 15 ms up to 3600 s – for dynamic measurements.
    • 4 MB on-board memory (expandable to 128 MB) for storage of measured values.
    • Fast and easy connection to a PC – RS232 and USB included as standard; optional IEEE488, Ethernet, or USB2.0.
    • PI1 process interface to measure torque and speed with external sensors, plus four analog outputs for easy use on motor and drive applications.
    • 341 kHz or 1 MHz sample rates for detailed signal analysis.
    • Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision.
    • Fluke NormaView PC software for data download, analysis & report writing.

    Standard Configurations

    Short Description | Description
    Fluke-N4K 1PP42 Fluke-Norma 4000, single phase with PP42 power phase input module
    Fluke-N4K 3PP42 Fluke-Norma 4000, three phase with 3xPP42 power phase input modules
    Fluke-N4K 3PP42I Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N4K 3PP42IP Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N4K 3PP42B Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with current binding post
    Fluke-N4K 3PP42IB Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with current binding post with IEEE488 / Ethernet interface
    Fluke-N4K 3PP42IPB Fluke-Norma 4000, three phase with 3xPP42 power phase input modules with current binding post with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N4K 3PP50 Fluke-Norma 4000, three phase with 3xPP50 power phase input modules
    Fluke-N4K 3PP50I Fluke-Norma 4000, three phase with 3xPP50 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N4K 3PP50IP Fluke-Norma 4000, three phase with 3xPP50 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N4K 3PP52IB Fluke-Norma 4000, three phase with 3xPP52 power phase input modules with current binding post with IEEE488 / Ethernet interface
    Fluke-N4K 3PP54I Fluke-Norma 4000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N4K 3PP54IP Fluke-Norma 4000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N5K 3PP50 Fluke-Norma 5000, three phase with 3xPP50 power phase input modules
    Fluke-N5K 3PP50I Fluke-Norma 5000, three phase with 3xPP50 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N5K 3PP50IP Fluke-Norma 5000, three phase with 3xPP50 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N5K 3PP54 Fluke-Norma 5000, three phase with 3xPP54 power phase input modules
    Fluke-N5K 3PP54I Fluke-Norma 5000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N5K 3PP54R Fluke-Norma 5000, three phase with 3xPP54 power phase input modules and printer
    Fluke-N5K 3PP54IP Fluke-Norma 5000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N5K 3PP54IR Fluke-Norma 5000, three phase with 3xPP54 power phase input modules with IEEE488 / Ethernet interface and printer
    Fluke-N5K 3PP64 Fluke-Norma 5000, three phase with 3xPP64 power phase input modules
    Fluke-N5K 3PP64I Fluke-Norma 5000, three phase with 3xPP64 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N5K 3PP64IP Fluke-Norma 5000, three phase with 3xPP64 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N5K 3PP64R Fluke-Norma 5000, three phase with 3xPP64 power phase input modules and printer
    Fluke-N5K 3PP64IR Fluke-Norma 5000, three phase with 3xPP64 power phase input modules with IEEE488 / Ethernet interface and printer
    Fluke-N5K 3PP64IPR Fluke-Norma 5000, three phase with 3xPP64 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels and printer
    Fluke-N5K 4PP54 Fluke-Norma 5000, three phase with 4xPP54 power phase input modules
    Fluke-N5K 4PP54IP Fluke-Norma 5000, three phase with 4xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N5K 6PP42IB Fluke-Norma 5000, three phase with 6xPP42 power phase input modules with current binding post with IEEE488 / Ethernet interface
    Fluke-N5K 6PP42IBR Fluke-Norma 5000, three phase with 6xPP42 power phase input modules with current binding post with IEEE488 / Ethernet interface and printer
    Fluke-N5K 6PP50IP Fluke-Norma 5000, three phase with 6xPP50 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N5K 6PP50IR Fluke-Norma 5000, three phase with 6xPP50 power phase input modules with IEEE488 / Ethernet interface and printer
    Fluke-N5K 6PP50IPR Fluke-Norma 5000, three phase with 6xPP50 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels and printer
    Fluke-N5K 6PP50I Fluke-Norma 5000, three phase with 6xPP50 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N5K 6PP54I Fluke-Norma 5000, three phase with 6xPP54 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N5K 6PP54IP Fluke-Norma 5000, three phase with 6xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N5K 6PP54IR Fluke-Norma 5000, three phase with 6xPP54 power phase input modules with IEEE488 / Ethernet interface and printer
    Fluke-N5K 6PP54IPR Fluke-Norma 5000, three phase with 6xPP54 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels and printer
    Fluke-N5K 6PP64I Fluke-Norma 5000, three phase with 6xPP64 power phase input modules with IEEE488 / Ethernet interface
    Fluke-N5K 6PP64IP Fluke-Norma 5000, three phase with 6xPP64 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels
    Fluke-N5K 6PP64IR Fluke-Norma 5000, three phase with 6xPP64 power phase input modules with IEEE488 / Ethernet interface and printer
    Fluke-N5K 6PP64IPR Fluke-Norma 5000, three phase with 6xPP64 power phase input modules with IEEE488 / Ethernet interface and analog / digital output channels and printer
  • General Specifications
    Number of Phases 1 to 3
    Weight Approx. 5 kg (11 lb)
    Size 150 x 237 x 315 mm
    5.9 x 9.3 x 12.4 in
    On-board Printer No
    Display Color, 5.7 in / 144 mm - 320 x 240 pixel
    User-selectable background lighting and contrast.
    Bandwidth DC to 3 MHz or DC to 10 MHz depending on input module
    Basic Accuracy 0.2%, 0.1% or 0.03% depending on input modules
    Sampling Rate 0.33 MHz or 1 MHz depending on input modules
    Voltage Input Range 0.3 V to 1000 V
    Current Input Range (direct, not via shunt) 0.03 mA to 20 A depending on input module
    Memory for Configurations 4 MB
    Memory for Settings 0.5 MB
    Fast Fourier Transformation (FFT) To the 40th harmonic
    RS232/USB Interface Standard
    PI1 Process interface (8 analog/impulse inputs and 4 analog outputs) Optional
    IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s) Optional
    Fluke NormaView PC software (for data download, analysis and report writing) Standard
    Basic Functions
    Fast Fourier Transformation (FFT) Calculation of harmonics with graphical representation. Up to 3 bar graphs are displayed at the same time.
    Measured values: U, I, P per phase
    Order: 1st to 40th harmonics, maximum half sample frequency
    Digital Oscilloscope (DSO) Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion.
    Integration function (energy) Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available.
    Vector Display Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal.
    Recorder Display of average values over time for trend determination.
    RAM data memory Storing of sample and average values; setting of start and stop conditions.
    From the RAM approximately 4 MB are available for the storage of measured values.
    Configuration Set up the analyzer to measure and display data in the format required.
    Ambient Conditions
    Working Temperature Range 5°C to 35°C (41°F to 95°F)
    Storage Temperature Range -20°C to 50°C (-4°F to 122°F)
    Housing Material Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements.
    Climatic Class KYG DIN 40040, max. 85% relative humidity, non-condensing.
    Power supply 85 V AC to 264 V AC, 50 Hz to 60 Hz, DC 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models.
    Measuring Inputs Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket.
    Operation Membrane keyboard with cursor – function keys and direct functions.
    Connections Rear panel of the 3-phase Analyzer
    Measured Values
      Non-gapping calculation of averaged values for each phase. In three phase system additionally calculation of total power and averaging of V and I of the three phases. The fundamental H01 will be calculated in synchronous mode also for these values.
    • Urms effective value, Urm rectified mean, Um mean value
    • Up-, Up+, Upp peak values
    • Ucf crest factor Ucf, Uff form factor
    • Ufc fundamental content
    • Uthd distortion factor DIN, IEC
    • Irms effective value, Irm rectified mean, Im mean value
    • Ip-, Ip+, Ipp peak values
    • Icf crest factor Icf, Iff form factor
    • Ifc fundamental content
    • Ithd distortion factor DIN, IEC
    • P active power [W]
    • Q reactive power [Var]
    • S apparent power [VA]
    • ë, cos. phase angular
    • Integral function for active power P, reactive power Q, apparent power S, voltage (Um) and current (Im),
    • Number of digits 4 or 5 dependent on measured value.
    Frequency and Synchronization
    Range DC and 0.2 Hz to sample rate
    Accuracy ±0.01% of measured value (reading)
     
    • Channels which can be selected: all U/I or external input.
    • One of three low pass filter with different frequencies can be switched into the signal.
    • The frequency is always visible on the top of the screen.
    • The BNC synchronization socket on backside of the instrument can be used either as input or output.
    • The input signals can be measured up to the sample rate of the power phase. The maximum level must not be higher then 50 V.
    • The output signal is a pulsed 5Volts TTL signal (frequency depends on the measured synch frequency).
    Configuration Memory
      Up to 15 user configurations can be saved into a permanent memory and reloaded later on. Changes that were not saved are lost after switching off the instrument.
    Interface
      RS232 interface for upload of firmware and data exchange with the PC. A printer can be connected over an external converter.
    Options IEEE 488.2 / 1 MBit/s
    Ethernet / 10 MBit/s or 100 Mbit/s
    Standards and Safety
    Electrical Safety EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III)
    Degree of pollution 2, safety Class I
    EN 61558 for transformer
    EN 61010-2-031/032 for accessories
    Maximum inputs For voltage inputs Measurement range 1000 Veff, 2 kVpeak
    For current inputs Measurement range 10 Aeff, 20 Apeak
    Test voltage Net input case (protective conductor): 1.5 KV AC
    Net connection Measurement input: 5.4 kV AC
    Measurement inputs Case: 3.3 kV AC
    Measurement input input: 5.4 kV
    Electromagnetic susceptibility Emission IEC 61326-1, EN 50081-1, EN 55011 Class B
    Immunity IEC 61326-1 / Annex A (industrial sector), EN 50082-1

    Power Phases

    The Fluke Norma 4000 Power Analyzer can be equipped with up to three power phases. Users can select the power phase best suited for their application.

    Each modular plug-in power phase consists of a voltage and a current measurement channel. Each measuring channel is available for each basic unit, however only one kind of channel can be used per unit. Check standard configurations.

    Power Phase Overview

    Power Phase Channels
    PP42 Accuracy 0.2% (0.1% rd + 0.1% rg)
    Current range 20 A
    Sampling rate 341 kHz
    Bandwidth 3 MHz
    PP50 Accuracy 0.1% (0.05% rd + 0.05% rg)
    Current range 10 A
    Sampling rate 1 MHz
    Bandwidth 10 MHz
    PP54 Accuracy 0.1% (0.05% rd + 0.05% rg)
    Current range 10 A
    Sampling rate 341 kHz
    Bandwidth 3 MHz
    PP64 Accuracy 0.03% (0.02% rg + 0.01% rg)
    Current range 10 A
    Sampling rate 341 kHz
    Bandwidth 3 MHz

    Current Shunts

    Planarshunt
    Continuous load (Imin)
    Range (Imax)
    0.3 A
    32 A
    Nominal current (calibration point) 32 A
    Basic accuracy at calibration point [%] ± 0.03
    Basic accuracy at nominal current [%] ± 0.03
    Nominal voltage drop [V] 320 mV
    Nominal resistance [Ohm] 10 mΩ
    Short time overrange
    (5s load 15s interval)
    100A/ 1s-5s
    Overload Wmax -
    Bandwidth DC - 1 MHz
    Frequency range -
    Angular accuracy [°/kHz] ± 0.1
    Frequency influence [%/kHz] -
    Load influence [%/A2] -
    Temperature coefficient [ppm/K] ≤10
    Weight (kg / lbs) 0.62 /1.36

    Triaxialshunts
    Continuous load (Imin)
    Range (Imax)
    0.1 A 1 A 6 A
    30 A 100 A 300 A
    Nominal current (calibration point 10 A 30 A 100 A
    Basic accuracy at calibration point [%] ± 0.03 ± 0.03 ± 0.1
    Basic accuracy at nominal current [%] ± 0.03 ± 0.03 ± 0.1
    Nominal voltage drop [V] 100 mV 30 mV 20 mV
    Nominal resistance [Ohm] 10 mΩ 1 mΩ 0.2 mΩ
    Short time overrange (5s load 15s interval) 35 A 200 A 450 A
    Overload Wmax 90 W 200 W 2 kW
    Bandwidth 2 MHz 2 MHz 1 MHz
    Frequency range 0 to 500 kHz 0 to 200 kHz 0 to 100 kHz
    Angular accuracy [°/kHz] ± 0.001 ± 0.002 ± 0.002
    Frequency influence [%/kHz] ± 0.0015 ± 0.0015 ± 0.01
    Load influence [%/A2] 1 x 10-6 1 x 10-6 1 x 10-6
    Temperature coefficient [ppm/K] ≤15 ≤15 ≤10
    Weight (kg / lbs) 0.75 / 1.65 0.75 / 1.65 1.2 / 2.65

    Triaxialshunts (Cont.)
    Continuous load (Imin)
    Range (Imax)
    2 A 18 A 18 A
    450 A 1000 A 1500 A
    Nominal current (calibration point 150 A 300 A 500 A
    Basic accuracy at calibration point [%] ± 0.1 ± 0.1 ± 0.1
    Basic accuracy at nominal current [%] ± 0.1 ± 0.1 ± 0.1
    Nominal voltage drop [V] 75 mV 15 mV 30 mV
    Nominal resistance [Ohm] 0.5 mΩ 0.06 mΩ 0.06 mΩ
    Short time overrange (5s load 15s interval) 650 A 1500 A 2000 A
    Overload Wmax 10 kW 7.5 kW 10 kW
    Bandwidth DC - 500 MHz DC - 500 kHz DC - 200 kHz
    Frequency range 0 to 100 kHz 0 to 20 kHz 0 to 20 kHz
    Angular accuracy [°/kHz] ± 0.025 ± 0.025 ± 0.025
    Frequency influence [%/kHz] ± 0.03 ± 0.03 ± 0.03
    Load influence [%/A2] 0.5 x 10-6 0.2 x 10-6 0.5 x 10-6
    Temperature coefficient [ppm/K] ≤10 ≤10 ≤10
    Weight (kg / lbs) 6 / 13.2 5.3 / 11.7 6 / 13.2
    • Models
      Model Name Description  
      Fluke Norma 4000 Fluke Norma 4000 Power Analyzer
      (consult datasheet for available models featuring different measurement and interface modules)
       

      Includes:

      • Power supply cable
      • 5.7“ / 144 mm color display
      • RS232/USB interface for data download
      • Space for three power-phases and options
      • Fluke NormaView PC software
      • User’s manual
      • Test certificate
      • Calibration values
  •  Product Registration
     
     Software Downloads