Fluke 41B Power Meter

The Fluke 41B Harmonics Analyzer combines the ease of use of a digital multimeter, the visual feedback of an oscilloscope and the power of a harmonics analyzer in a single instrument.

This product is discontinued or reclassified

Fluke suggests:

Fluke 43B Single Phase Power Quality Analyzer »

Overview
Features
Specs
Models
Accessories
Resources
  • The Fluke 41B Harmonics Analyzer combines the ease of use of a digital multimeter, the visual feedback of an oscilloscope and the power of a harmonics analyzer in a single instrument. If you're testing power on three-phase systems or trouble-shooting harmonics on non-linear loads, no test tool makes it easier.

    The Model 41B is ideal for further analyzing data and optimizing system performance. Use the Fluke 41B's FlukeView® software (included) to download acquired data to a printer or an MS-DOS® or Windows® compatible computer for analysis and presentation.

  • Features at a Glance

    Three Views of each reading

    • Waveform
    • Bargraph showing harmonic levels
    • Numeric values

    Real-time Display Updates

    Display updates three times a second for a dynamic view of actual circuit conditions.

    Comprehensive Measurements

    Measure rms, peak and total harmonic distortion (THD) for complex voltages and currents - with no manual calculations required. Three Phase Readings

    Three-Phase readings

    From a simple single-phase measurement, automatically calculates three-phase power for 3-wire balanced loads (typically 5% or less imbalance). To make the single-phase measurement, simply connect the meter as shown and select the 3º, 3C watts display.

    System Critical Data

    Immediate readings of Power Factors, KVAR, Crest Factor, K-Factor.

    Display Harmonics individually to the 31st

    Min/Max and Average Recording

    Data Storage

    Up to eight complete measurement sets.

    Isolated Serial Interface

    Communications with a serial printer or DOS® or Windows®-compatible computer.

    Safety Designed

    To meet the latest standards: IEC 1010-1, pollution degree 2, Installation Category III, material group II, 600 V. Double insulated protection as described in IEC 1010-1, Annex H.

    Display

    One cycle of the fundamental waveform and its frequency. Instantaneous voltage at cursor position.

    Application

    Application

    Identifying sources of harmonic currents. Obtaining data for designing, specifying or sizing transformers, filters, etc.

    Display

    %-fundamental or %-rms, rms value, frequency, and phase angle of fundamental or harmonic currents (up to 31st), as selected by cursor from bar graph. Application

    Application

    Identifying sources of harmonic currents. Obtaining data for designing, specifying or sizing transformers, filters, etc.

    Display

    Watts, volt-amps, power factor (total) and displacement power factor of fundamental of single-phase or three-phase power.Application

    Application

    Identifying displacement versus total power-factor. Determining proper power-factor correction methods.

  • Measurement Accuracy
    Voltage Range and resolution  5.0 V to 600 V rms (AC+DC); ±5.0 V to ±933 V peak
    Accuracy  rms: ±(0.5 % + 2 digits); Peak or DC: ±(2 % + 3 digits) (Add 2 digits if < 15 V rms)
    Current (1mV/A) isolated input Range and resolution  1.00 A to 1000 A rms (AC+DC); ±1.0 A to ±2000 A peak
    Accuracy  rms: ±(0.5% + 3 digits)+probe specs; Peak or DC: ±(2 % + 4 digits) + probe specs
    Watts/Volt-Amps (1mV/A) isolated input Range and resolution 0.0W(VA) to 600 kW(kVA) average;
     0.0W(VA) to ±2000 kW(kVA) peak
    Accuracy  AC+DC: ±(1 % + 4 digits) + probe specs
    Harmonics (harmonic level >5% using Smooth 20) Volts Fundamental to 13th ±(2 %+2 digits);
    At 31st ±(8 %+2 digits);
    Amperes or watts  Fundamental to 13th ±(3 % + 3 digits) + probe specs;
     At 31st ±(8 % + 3 digits) + probe specs
    Frequency Range and resolution  6.0 Hz to 99.9 Hz
    Accuracy  ±0.3 Hz
    Input bandwidth  DC, 6 Hz to 2.1 kHz
    Crest factor (CF) Range and resolution  6.0 Hz to 99.9 Hz
    Accuracy  ±0.3 Hz
    Power factor (PF) Range and resolution  0.00 to 1.00
    Accuracy  ±0.02
    Displacement power factor (DPF) Range and resolution  0.00 to 1.00
    Accuracy  ±0.04 to ±0.03 (0.30 to 0.89) ±0.02 (0.90 to 1.00)
    Phase Range and resolution  -179 º to 180 º
    Accuracy (Fundamental)  ±2 º + probe specs
    K-Factor (KF) Range and resolution  1.0 to 30.00
    Accuracy  ± 10%
    % THD-F Range and resolution  0.00 % to 799.9 %
    Accuracy  ±(0.03 Reading + 2.0 %)
    % THD-R Range and resolution  0.0 % to 99.9 %
    Accuracy  ±(0.03 Reading + 2.0 %)
    General Specifications
    Minimum input levels  5 V rms or 1 A rms
    Battery life  4 alkaline "C" cells ANSI/NEDA-14A, IEC-LR14 (supplied) 48 hours typical (continuous)
    Shock and vibration  Per MIL-T-28800, Class 3
    Case  Drip-Proof and Dust-Proof per IEC, IP 52
    Size  234 mm L x 100 mm W x 64 mm D (9.2" L x 3.9" W x 2.5" D)
    Weight  0.9 kg (2.0 lb.)
    Warranty  One Year Warranty
    • Model
      Model Name Description  
      Fluke 41B Fluke 41B Power Meter
      Fluke 41B Power Meter

      Includes: 

      • Isolated RS-232 Cable
      • FlukeView® Software
      • Software Manual
      • 80i-500s AC Current Probe
      • TL24 Test Leads
      • AC20 Test Clips
      • TP20 Test Probes
      • Operator's manual
    • Manuals
      Title  
      39/41B Users Manual Download
      39/41B Mode d'emploi Download
      39/41B Bedienungshandbuch Download
      39/41B Manuale per l’uso Download
      39/41B Manual de uso Download
      39, 40, 41, 41B, 41B/AA Statement of Memory Volatility Download
      39/41B Service Manual Download
    • Application Notes
      Title  
      Who sets the rules for electrical testing and safety? Download
    • Brochures
      Title  
      Fluke Power Quality Family Brochure Download