Fluke 196C Handheld Digital Storage Oscilloscope

Fluke ScopeMeter® 190 series high performance digital oscilloscopes are rugged, compact, battery powered & they troubleshoot demanding industrial applications.

This product is discontinued or reclassified

Fluke 196C
Overview
Features
Specs
Models
Accessories
Resources
  • ScopeMeter® 190 Series: Speed, performance and analysis power

    For the more demanding applications, the ScopeMeter 190 Series high-performance oscilloscopes offer specifications usually found on top-end bench instruments. With up to 200 MHz bandwidth, 2.5 GS/s real-time sampling and a deep memory of 27,500 points per input they’re ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery powered instrument.

  • ScopeMeter® 190 Series : All this power in your hand!
    ScopeMeter 190C and 190B Series test tools have specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in today’s state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They’re rugged, compact and battery powered.

    • Dual-input - 200, 100 or 60 MHz bandwidth
    • Up to 2.5 GS/s real-time sampling per input
    • High resolution Color display
    • High waveform resolution of 3,000 datapoints per channel (NEW)
    • Connect-and-View™ automatic triggering and a full range of manual trigger modes
    • Frequency Spectrum Analysis using FFT
    • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
    • Fast display update rate for seeing dynamic behavior instantaneously
    • Automatic capture and replay of 100 screens
    • 27,500 points per input record length using ScopeRecord™ mode
    • TrendPlot™ paperless chart recorder for trend analysis up to 22 days
    • Up to 1000 V independently floating isolated inputs
    • Waveform reference for visual comparisons and automatic pass/fail testing of waveforms
    • Vpwm function for motor drive and frequency inverter applications.
    • 1000 V CAT II and 600 V CAT III safety certified
    • Four hours rechargeable Ni-MH battery pack
    • Industrial Bus Test capabilities available in new models



    See what’s really happening

    High sampling rate gives you the required resolution for detailed signal analysis


    With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window – giving a far better overview of what’s happening both before and after the trigger event!

    Deeper waveform acquisition memory

    Thanks to the deeper memory, very small parts of the waveform can be studied in full detail using ‘zoom’.


    The waveform memory of all oscilloscopes in the 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software.

    Easier identification of traces, everywhere

    Color traces and the high contrast display make signal identification easy


    The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured!

    See dynamic signal behavior instantaneously

    Digital persistence mode gives analog scope like display of complex and modulated signals


    The Digital Persistence uses multiple intensity levels and user selectable decay time -it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast display update rate that’s a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.

    Advanced trigger modes

    Pulse width triggering allows you to find anomalies like missing pulses


    A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you’ll encounter. Connect-and-View™ triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal.

    More advanced triggering

    Dual-slope triggering used to capture the eyepattern on a digital datastream.


    Two new modes – ‘n-cycle triggering’ and ‘dual-slope triggering’ – have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ‘live’ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike.
    This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena.

    Automatic capture and replay of 100 screens


    Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze the last 100 screens and scroll through picture-by-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC.

    Deep memory for high-resolution ScopeRecord™

    Use the 27,500 points memory of the ScopeRecord mode and zoom in for maximum detail


    The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermittents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ‘Stop-on-Trigger’ in the ScopeRecord mode. This allows the ScopeMeter test tool to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis.

    Measure from mV to kV – fully isolated and safely!

    Use Vpwm and measure effective voltage on motor drive and frequency inverter outputs


    The ScopeMeter 190 Series test tools have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different "low" level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications.

    Analysis power

    A wide variety of measurements can be made on either Channel A or B


    For analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 15 scope screens can be stored for analysis, print-out or download to a PC.

    Frequency Spectrum Analysis

    Frequency Spectrum shows an overview of frequencies contained in a signal.


    All 190C Color ScopeMeter test tools now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window.

    Waveform Pass / Fail Testing

    Pass/Fail testing of actual signal against a reference template


    ‘Waveform reference’ allows an acquired trace to be stored and designated ‘reference trace’ for visual comparisons, or it can be used as the reference for automatic ‘Pass / Fail’ testing. Up to 100 individually matching (‘Pass’) or non-matching (‘Fail’) waveforms can be stored in the replay memory, allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend!

    Cursor-limited automatic measurement

    The rms-value of the noise is measured on the part of the waveform enclosed by the cursors.


    Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter test tool can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time.

    ... and there is more

     

    • Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V
    • The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters.
    • The high-sensitivity setting of 2 mV/div allows for measurements on low-level signals, that are hard to make with the average oscilloscope.
    • For use on medical imaging equipment and on high-resolution video systems, a optional configuration is available or the Fluke 190 Series that supports measurement of current over time (mAs), triggering on high-resolution video systems (up to 2800 lines) and more.



    Use TrendPlot™ to help find intermittents, fast

    Cursors and zoom help you analyze the captured TrendPlot


    The toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it - your Fluke ScopeMeter test tool will. In this "paperless recorder" mode, you can plot the minimum and maximum peak values and average over time - up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase - with time and date stamp - to help lead you to the cause of those faults quickly.

    FlukeView® Software for documenting, archiving and analysis


    FlukeView® for Windows® helps you get more out of your ScopeMeter test tool by:

     

    • Documenting - transfer waveforms, screens and measurement data from the ScopeMeter test tool to a PC. Print or import the data into your report
    • Add user text to individual test tool settings - providing guidance to the operator when recalling a set-up.
    • Archiving – create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the ScopeMeter test tool on your PC for back-up purposes
    • Waveform Compare - store reference waveforms on the PC, or send a reference back to the ScopeMeter test tool for waveform comparison and "Pass/Fail" testing.
    • Analysis - use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 or USB interface cable. Software and cable are available as separate accessories or as part of the more cost-efficient SCC-kit (software, interface cable and hard shell carrying case).
  • Specifications
    Bandwidth
    Fluke 199C:  200 MHz
    Fluke 196C:  100 MHz
    Fluke 192C:  60 MHz
    Real-time sample rate
    Fluke 199C:  2.5 GS/s
    Fluke 196C:  1 GS/s
    Fluke 192C:  500 MS/s
    Inputs and digitizers
       2 plus external / DMM input
    Independently floating isolated inputs
       Up to 1000 V between inputs, references and ground
    Timebase range
       5 ns - 2 min/div
       10 ns - 2 min/div (192B)
    Input sensitivity
    190C Models:  2 mV-100 V/div
    Trigger types
    190C Models:  Connect-and-View™, Free Run, Single Shot, Edge, Delay, Video, Selectable pulse width and External
       Dual slope trigger and Event trigger (n-cycle)
    Glitch capture
       50 ns (5 µs/div - 1 min/div)
    Scope measurements
    Cursor:  7
    Automatic:  30
    Maximum record length
    ScopeRecord mode:  27,500 pts per input
    Scope mode:  3,000 pts per input
    Memory
    Screens + Setups:  15
    Replay + Setups:  2
    Display
    190C Models:  144 mm full color LCD with fast update rate
    Persistence
    190C Models:  Digital persistence giving analog oscilloscope-like waveform decay
    Waveform Compare
    190C Models:  Waveform reference with automatic Pass/Fail testing
    Environmental Specifications
    Operating Temperature
       0ºC to 50ºC
    Storage Temperature
       -20°C to +60°C
    Operating Altitude
       3,000 m
    Safety Specifications
    Electrical Safety
       1,000V CAT II/600V CAT III (EN61010-1)
    Mechanical & General Specifications
    Size
       256 x 169 x 64 mm
    Weight
       2.0 kg
    Warranty
       3-years on main instrument, 1-year on accessories
    Battery Life
    NiMH:  4 hrs
    RS232/USB Interface
       Optically isolated via optional PM9080/OC4USB for interfacing to Printer or PC
    • Model
      Model Name Description  
      Fluke 196C Fluke 196C Handheld Digital Storage Oscilloscope
      Handheld Digital Storage Oscilloscope

      Color ScopeMeter (100 MHz / 1 GS/s)

    • Manuals
      Title  
      19xC-2x5C Users Manual Download
      192/196/199 & 196C/199C Programmers Guide Download
      192B, 196B, 199B, 192C, 196C, 199C, 215C, 225C Statement of Memory Volatility Download
      19xC-2x5C Getting Started Download