English

Fluke 376 FC True-RMS Clamp Meter with iFlex

Model#: Fluke 376 FC with 18-inch iFlex Part#: 5065965 UPC#: 0 95969 79839 6
Fluke 376 FC True-RMS Clamp Meter with iFlex is rated 4.6 out of 5 by 49.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.63ms
  • REVIEWS, PRODUCT
  • 376fc
  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
  • 376 fc contents in box

Key features

  • Measures AC current with included 18-inch or 36-inch iFlex current probe
  • VFD low pass filter for accurate measurements of non-linear signals
  • Remotely log, trend and monitor to pinpoint intermittent faults
  • Inrush measurement to filter out noise and capture starting current
In stock
$659.99
FREE Shipping
30-day Returns

Product overview: Fluke 376 FC True-RMS Clamp Meter with iFlex

The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.

Find the cause of difficult problems

The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.

Measure:

  • Voltage to 1000 V AC or DC
  • Resistance to 60 kΩ with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV DC measurement range to interface with other accessories
  • 1000 μF capacitance measurement
  • Work safely and conveniently
  • The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.

The included 18-inch or 36-inch iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:

  • Expands the measurement range to 2500 A AC
  • Allows frequency measurement to 500 Hz with body jaw and iFlex

What's in the box:

  • Fluke 376 FC True-RMS Clamp Meter
  • 18-inch or 36-inch iFlex® Flexible Current Probe
  • TPAK magnetic hanging strap
  • TL75 Test Leads
  • Two AA batteries (Installed)
  • Soft carrying case

Specifications: Fluke 376 FC True-RMS Clamp Meter with iFlex

General Specifications
AC Current via Jaw
Range999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz)3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range2500 A
Resolution0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Flexible current probe
 i2500-10 Flexi2500-18 Flexi2500-36 Flex
A   
Distance from Optimum0.5 in (12.7 mm)1.4 in (35.6 mm)4.8 in (122.2 mm)
Error±0.5 %±0.5 %±0.5 %
B   
Distance from Optimum0.8 in (20.3 mm)2.0 in (50.8 mm)5.3 in (133.6 mm)
Error±1.0 %±1.0 %±1.0 %
C   
Distance from Optimum1.4 in (35.6 mm)2.5 in (63.5 mm)5.8 in (147.6 mm)
Error±2.0 %±2.0 %±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range999.9 A
Resolution0.1 A
Accuracy2% ±5 digits
AC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1% ±5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1% ±5 digits
Frequency via Jaw
Range5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range60 kΩ
Resolution0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy1% ±5 digits
Capacitance
Range1000 μF
Resolution0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground1000 V
Batteries2 AA, NEDA 15A, IEC LR6
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity -
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude2000 m
Storage altitude12,000 m
Size (L x W x H)249 x 85 x 45 mm
Weight395 g
Jaw opening34 mm
Flexible current probe diameter7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
  
IP ratingIEC 60529: IP30, non-operating
Radio Frequency Certification FCC IDT68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

Models: Fluke 376 FC True-RMS Clamp Meter with iFlex

Fluke 376 FC with 18-inch iFlex

Fluke 376 FC True-RMS Clamp Meter

Part#: 5065965
UPC#: 0 95969 79839 6

Includes:

  • Fluke 376 FC True-RMS Clamp Meter
  • 18-inch iFlex® Flexible Current Probe
  • TPAK magnetic hanging strap
  • TL75 Test Leads
  • Two AA batteries (Installed)
  • Soft carrying case
  • Coated instruction card
  • Safety information sheet
Fluke 376 FC with 36-inch iFlex
Fluke 376 FC True-RMS Clamp Meter
Part#: 5278833
UPC#: 1 95112 02098 2
Includes:
  • Fluke 376 FC True-RMS Clamp Meter
  • 36-inch iFlex® Flexible Current Probe
  • TPAK magnetic hanging strap
  • TL75 Test Leads
  • Two AA batteries (Installed)
  • Soft carrying case
  • Coated instruction card
  • Safety information sheet
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.33ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 5 out of 5 by from Superior by Design This is a great multimeter. I especially love the Bluetooth feature with the remote phone app. I am retired now and needed a good meter for use with my hobbies and around the house. While employed we used Fluke test equipment at work all the time. Top of the line product.
Date published: 2023-05-16
Rated 3 out of 5 by from Love the meter itself I just replaced my old 376 which is identical to the new one minus the Fluke Connect option and I fail to remember if the old one did caps but whatever on that point. These companies.....advertise in huge letters how you can measure away from the flash point but conveniently put it lower in small print that you only have so much storage space free. When you install fluke connect, it even tells you 365 days free, then you need to buy a subscription. This kind of shady crap will make someone buy something different next time. I like all my Fluke meters and I have a lot of them, but I am tired of companies doing crap like this and will not support it anymore. Be up front so people can make informed decisions while not having to read your pages with a magnifier to find all the pitfalls.
Date published: 2023-04-06
Rated 5 out of 5 by from Good features Professional electrician for over 20 yrs and this is by far the best meter I have owned. The DC mv is great for testing low voltage signals and the flex adapter make it so much safer to get amperage readings inside transformers and cabinets keeping you away from exposed lugs and bus bars. Highly recommend the fluke 376fc.
Date published: 2021-10-16
Rated 5 out of 5 by from Very Pleased Very pleased with the meter. The Bluetooth is great, but it's only part of the meter's great features. And I've only begun to play with it.
Date published: 2021-09-30
Rated 4 out of 5 by from Pretty nice rig for the money, BUT... I bought this meter for the sole purpose of remote monitoring a motor current (50'-60' away). It's easy to use; the iOS app and Android app work well for what I'm doing, and allows me to export a .xls file for external analysis. The bluetooth range out of the box is horrible; made it 20' before signal drop out. Proceed at your own risk. This meter uses a pre-certified bluetooth radio board with a built in chip antenna. I disassembled the meter and removed the chip antenna; replaced it with a piece of solid core 24AWG wire 31mm long (2.4GHz 1/4 wave). Reassembled the meter and now my wireless range is in excess of 150'. Did this on day 1, so no warranty now. Whatever. :)
Date published: 2021-08-31
Rated 5 out of 5 by from 376 FC True RMS I’ve used fluke products ever since I started electrician work (25years) ,all have been top notch. The 376 FC is one notch above the top. Best meter on the market for the money and the I flex amp tool makes troubleshooting in tight places much easier and safer.
Date published: 2021-05-30
Rated 4 out of 5 by from Great daily carry meter. But ex-381 owners beware TLDR: Great general purpose meter, will fill just about everything you need for a meter 90% of the time. BUT be leery about coming to this from the older Fluke 381, all the specs are the same...but the wireless functionality is much worse (Use: Industrial Electrician) I bought this meter to replace my Fluke 381. I had been using the 381 for years as a general multimeter and loved it. It gives you just about everything you need for daily driving it as your carry matter, and having BOTH AC & DC up to 1000 amp on the clamp is a sweet bonus. The one issue I had was that whenever I got a service call to troubleshoot an unknown issue that would have a surprise capacitive circuit(because the customer had no clue). this was an issue because the 381 does not have a capacitance test setting, so I would have to go back out through the facility to get my megger which has the setting in it. Seeing as how this 376FC has the exact reading specifications as the 381, plus the capacitance and mV additions, I figured it was a great buy. Overall it is, the meter works great and is almost as handy as the 381. The reason I give it 4 stars is because the Bluetooth is just terrible, and doesn't get you very far before it cuts out. I used to use the 381's removable display a lot, very handy for troubleshooting by yourself, I was hoping the Fluke Connect app could replace that function and make it an even trade off....it very much does not. If you have direct line of sight it will go about 30'-35', HOWEVER if you don't have L.O.S (like when it is in a closed cabinet as advertised, or when you are troubleshooting controls from elsewhere on a line) you loose connectivity at about 8-10'. That is rubbish, my ear buds stay connected 90' L.O.S and 45' through concrete walls and machinery....they should put a better BT version in this. Unfortunately it also doesn't come close to the 381's removable display distance either as I had no issues through obstacles with that either at 30-40' (assuming it was a lower frequency radio?). That is also separate from the functionality of the less than stellar fluke connect app itself. So sadly, even though this is newer than the available Fluke 381, and has more measurement features...the wireless does not live up to the 381's practically, and makes me wish they would refresh that with stronger/better radios and more measurements.
Date published: 2020-08-17
Rated 1 out of 5 by from Dont waste your money. This meter may work ok standalone. I bought it specifically for the fluke connect app. Doesnt work with my phone. No compatibility chart on web page. This thing is borderline paperweight.
Date published: 2020-07-28
  • y_2024, m_3, d_12, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_4, tr_45
  • loc_en_US, sid_1627876393012, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 25.29ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.

Fluke Connect is not available in all countries.

*Not all models are available in all countries. Check with your local Fluke representative.

© Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4s and up running iOS 8 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

Welcome to Fluke's Chat GPT Assistant. As with other generative AI systems, this chatbot may occasionally generate incorrect information. For questions regarding the safe use of Fluke tools, please refer to your owners manual. You must comply with your employer’s safety standards and obtain necessary training before using Fluke tools or taking electrical measurements. To speak with a person, visit our Contact Us page.
How can I help you today?