-
You’re going to love what we’ve done with your calibrator.
The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.
The 754 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package.
For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
HART Capabilities
The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator.
To create a seamless/paperless calibration management system consider adding Fluke DPCTrack2 Calibration Management software for use with your Fluke 753 and 754 or even legacy Fluke 743 and 744 calibrators.
The Fluke 754 Documenting Process Calibrator-HART: Work smarter. Work faster.
-
Work smarter. Work faster.
The 754 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. The 754 also features a powerful built in HART® interface capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.
- Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
- Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
- Power transmitters during test using loop supply with simultaneous mA measurement
- Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
- Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
- Holds up to a full week of downloaded procedures and calibration results.
- Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
- Easy to use
- Three year warranty
- Bright white dual display. Read both sourced and measured parameters simultaneously.
- Multi lingual interface
- Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
- Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
- Delivered with DPC/Track Sample software.
- Compatible with many Asset Management software packages.
HART Capabilities
The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers the communication capabilities of the 375 HART communicator.- Requires no external box or second tool for everyday HART calibration and maintenance.
- Offers fast HART communication.
- Supports popular models of HART transmitters, with more devise-specific command support than any other HART field calibrator.
- Works with multiple masters, burst mode, and multi-drop configurations.
- Is easy to update as additional instruments are added and new HART versions are released.
- Interrogate to determine device type, manufacturer, model, tag.
- Reconfigure the sensor mapping of dual sensor temperature transmitters.
- Read HART PV function and smart transmitter digital output while measuring analog mA output.
- Read and write HART configuration functions to make field adjustments to PV range points, damping, and other top-level configuration settings.
- Re-label smart transmitters by reading and writing to the HART tag field.
Versatile HART Protocol support
Manufacturer Pressure instruments Temperature instruments Coriolis instruments ABB/Kent-Taylor 600T 658T1 ABB/Hartmann & Braun Contrans P1,
AS 800 SeriesEndress & Hauser CERABAR S,
CERABAR M,
DELTABAR STMT 1221,TMT 1821,
TMT 1621Foxboro Eckardt TI/RTT201 Foxboro/Invensys I/A Pressure Fuji FCX
FCXAZFRC Honeywell ST3000 STT25T1,
STT25H1Micro Motion 2000
2000 IS
9701
9712
9739Moore Products 3441 Rosemount 1151
2088
3001C
3051, 3051S3044C
644
3144
3244, 3144PSiemens SITRANS P DS
SITRANS P ESSMAR LD301 TT3011 Viatran I/A Pressure Wika UNITRANS T32H1 Yokogawa EJA YTA 110, 310
and 3201Sensor Trim not supported
The 754 supports the commands contained in HART protocol Version 5.7. With 2 MB of memory, the 754 supports a substantial set of HART instructions:
- Universal commands provide functions that are implemented in all field devices, for example, read manufacturer and device type, read primary variable (PV), or read current output and percent of span.
- Common practice commands provide functions that are common to many but not all field devices, for example read multiple variables, set damping time, or perform loop test.
- Device-specific commands provide functions that are unique to a particular field device, for example sensor trim.
HART Operating Modes Supported
- Point to Point operation , the most commonly used mode, connects the 754 to a single HART device in a 4-20 mA loop.
- In Multi-Drop mode , several HART instruments can be bussed together. The 754 searches for each, identifies addresses in use, and allows you to select the instrument for calibration and related operations.
- In Burst Mode, the HART instrument transmits bursts of data without waiting to be interrogated by a master unit. The 754 can take transmitters out of burst mode during test or calibration, then later restore them to burst mode.
Pressure Modules
Covers virtually any pressure application including gauge, differential, dual (compound), absolute, and vacuum.
- Display pressure readings in any of 10 different pressure units you specify in the calibrator setup.
- Rugged urethane molded cases protect the modules from rough handling and harsh conditions.
- Features internal temperature compensation from 0° to 50°C for full accuracy performance.
- Includes NIST-traceable calibration certificate.
- Modules can be calibrated locally, helping to control costs.
A family of 29 optional pressure modules provides pressure calibration and measurement capabilities. Twenty-eight modules are available, with basic accuracy specs to 0.05%. Ranges start at 0 – 1 inH20 (0 – .25kPa) and go to 0 – 10,000 psi (0 – 70,000 kPa). Additional information about pressure modules is available on the Pressure Modules Home Page.
Automated Procedures
Allow you to quickly set up powerful, automated calibration procedures for linear transmitters, DP flow transmitters, and one- and two-point limit switches. Simply select the appropriate measure and/or source functions and fill out the procedure template. The 750 Series does the rest. It quickly performs the test, calculates the errors, and displays the final results, highlighting out of tolerance points.
Custom Units
Enable you to map one unit to another, such as mV to °C or °F. Allows you to use the Fluke 750 Series with millivolt output accessories such as the Fluke 80T-IR Temperature Probe, and to document tests using non-supported units such as parts per million or revolutions per minute.
User-entered Values
Enables technicians to record calibration results that were sourced and/or measured by other devices such as panel meters or readout-only devices.
Limit Switch Calibration
Procedures perform fast, automated calibration of one and two-point limit switches for voltage, current, temperature, and pressure.
Differential Pressure Flow Instrument Calibration
Routines use a square root function to directly calibrate DP flow instruments.
Additional Features
MultifunctionalCalibrate temperature, pressure, voltage, current, resistance, and frequency. Since it both measures and sources, you can troubleshoot and calibrate all with one rugged tool.
Powerful, yet easy to use
The easy-to-follow menu-driven display guides you through any task. Get up to speed in minutes, not days. Programmable calibration routines enable you to create and run automated as-found/as-left procedures to ensure fast, consistent, calibrations.
Records and documents results
To support your ISO-9000 or regulatory standards the Fluke 754 captures your calibration results, eliminating the need to juggle a pen and pad in the field. The USB interface lets you transfer the results to a PC, thus saving the time of having to manually transcribe them when you return to the shop.
Truly hand-held
Small enough to fit easily into a tool bag and to use in tight spaces. Runs an entire shift on a rechargeable Li-ion battery pack.
Rugged and reliable
Count on Fluke's rugged design to deliver top accuracy and reliability in harsh environments. Overmolded urethane case stands up to rough handling in industrial environments.
Bright white display
Lets you read your results in any kind of light. Backlight has three (3) settings.
Soft keys
Provide one-touch access to enhanced functions such as task lists, automated procedures, scaling, min/max, stepping and ramping, and review memory.
Three operating modes
Measure, Source, or simultaneous Measure/Source, - enable technicians to troubleshoot, calibrate, or maintain instrumentation with just one tool.
Multi-lingual interface
Displays instructions in English, French, German, Spanish, and Italian.
Built-in algebraic calculator
With four functions-plus square root-stores, recalls, and performs calculations required for setting up instruments or evaluating data in the field. Use it to set the source function to a calculated value. There's no need to carry a pencil and paper or a separate calculator.
Programmable measurement delay
Inside automated procedures permits calibrating instruments that respond slowly.
-
Measurement Accuracy Voltage DC Range/Resolution 1 Year 2 Years 100.000 mV 0.02% + 0.005 mV 0.03% + 0.005 mV 3.00000 V 0.02% + 0.00005 V 0.03% + 0.00005 V 30.0000 V 0.02% + 0.0005 V 0.03% + 0.0005 V 300.00 V 0.05% + 0.05 V 0.07% + 0.05 V Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% + 0.002 V 1.0% + 0.004 V 30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% + 0.02 V 1.0% + 0.04 V 300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% + 0.2 V 1.0% + 0.2 V Current DC 30.000 mA 0.01% + 5 uA 0.015% + 7 uA 110.00 mA 0.01% + 20 uA 0.015% + 30 uA Resistance 10.000 Ω 0.05% + 50 mΩ 0.07% + 70 mΩ 100.00 Ω 0.05% + 50 mΩ 0.07% + 70 mΩ 1.0000 kΩ 0.05% + 500 mΩ 0.07% + 0.5 Ω 10.000 kΩ 0.1% + 10 Ω 0.15% + 15 Ω Frequency 1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz 110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz 1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz 11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz Source Accuracy 1 Year 2 Years Voltage DC 100.000 mV 0.01% + 0.005 mV 0.015% + 0.005 mV 1.00000 V 0.01% + 0.00005 V 0.015% + 0.0005 V 15.0000 V 0.01% + 0.0005 V 0.015% + 0.0005 V Current DC 22.000 mA (source) 0.01% + 0.003 mA 0.02% + 0.003 mA Current sink (simulate) 0.02% + 0.007 mA 0.04% + 0.007 mA Resistance 10.000 Ω 0.01% + 10 mΩ 0.015% + 15 mΩ 100.00 Ω 0.01% + 20 mΩ 0.015% + 30 mΩ 1.0000 kΩ 0.02% + 0.2 Ω 0.03% + 0.3 Ω 10.000 kΩ 0.02% + 3 Ω 0.03% + 5 Ω Frequency 0.1 to 10.99 Hz 0.01 Hz 0.01 to 10.99 Hz 0.01 Hz 11.00 to 109.99 Hz 0.1 Hz 110.0 to 1099.9 Hz 0.1 Hz 1.100 to 21.999 kHz 0.002 kHz 22.000 to 50.000 kHz 0.005 kHz Technical Data Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length 8000 readings (7980 for 30 or 60 readings/minute) Ramp functions Source functions Voltage, current, resistance, frequency, temperature Rate 4 steps/second Trip detect Continuity or voltage (continuity detection not available when sourcing current) Loop power function Voltage Selectable, 26 V Accuracy 10%, 18 V minimum at 22 mA Maximum current 25 mA, short circuit protected Maximum input voltage 50 V DC Step functions Source functions Voltage, current, resistance, frequency, temperature Manual step Selectable step, change with arrow buttons Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat Environmental Specifications Operating temperature -10°C to +50°C Storage temperature -20°C to +60°C Dust/water resistance Meets IP52, IEC 529 Operating altitude 3000 m above mean sea level (9842 ft) Safety Specifications Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 Mechanical and General Specifications Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in) Weight 1.2 kg (2.7 lb) Batteries Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh Battery life >8 hours typical Battery replacement Replace without opening calibrator; no tools required Side port connections Pressure module connector USB Connector to interface to your PC Digital instrument (HART) connector Connection for optional battery charger/eliminator Data storage capacity 1 week of calibration procedures results 90 day specifications The standard specification interval for the 750 Seriesare 1 and 2 years. Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2. Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant. Temperature, Resistance Temperature Detectors Degrees or % of reading - Type (α) Range °C Measure °C1 1 year 2 year 100 Ω Pt (385) -200 to 100
100 to 8000.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C200 Ω Pt (385) -200 to 100
100 to 6300.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C500 Ω Pt (385) -200 to 100
100 to 6300.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C1000 Ω Pt (385) -200 to 100
100 to 6300.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C100 Ω Pt (3916) -200 to 100
100 to 6300.07°C
0.02% + 0.05°C0.14°C
0.04% + 0.10°C100 Ω Pt (3926) -200 to 100
100 to 6300.08°C
0.02% + 0.06°C0.16°C
0.04% + 0.12°C10 Ω Cu (427) -100 to 260 0.2°C 0.4°C 120 Ω Ni (672) -80 to 260 0.1°C 0.2°C Source current Source °C Allowable current2 1 year 2 year 1 mA 0.05°C
0.0125% + 0.04°C0.10°C
0.025% + 0.08°C0.1 mA to 10 mA 500 μA 0.06°C
0.017% + 0.05°C0.12°C
0.034% + 0.10°C0.1 mA to 1 mA 250 μA 0.06°C
0.017% + 0.05°C0.12°C
0.034% + 0.10°C0.1 mA to 1 mA 150 μA 0.06 C
0.017% + 0.05°C0.12 C
0.034% + 0.10°C0.1 mA to 1 mA 1 mA 0.05°C
0.0125% + 0.04°C0.10°C
0.025% + 0.08°C0.1 mA to 10 mA 1 mA 0.05°C
0.0125% + 0.04°C0.10°C
0.025% + 0.08°C0.1 mA to 10 mA 3 mA 0.2°C 0.4°C 0.1 mA to 10 mA 1 mA 0.04°C 0.08°C 0.1 mA to 10 mA 1. For two and three-wire RTD measurements, add 0.4°C to the specifications.
2. Supports pulsed transmitters and PLCs with pulse times as short as 1 msTemperature, Thermocouples Type Source °C Measure °C Source °C 1 year 2 years 1 year 2 years E -250 to -200 1.3 2.0 0.6 0.9 -200 to -100 0.5 0.8 0.3 0.4 -100 to 600 0.3 0.4 0.3 0.4 600 to 1000 0.4 0.6 0.2 0.3 N -200 to -100 1.0 1.5 0.6 0.9 -100 to 900 0.5 0.8 0.5 0.8 900 to 1300 0.6 0.9 0.3 0.4 J -210 to -100 0.6 0.9 0.3 0.4 -100 to 800 0.3 0.4 0.2 0.3 800 to 1200 0.5 0.8 0.3 0.3 K -200 to -100 0.7 1.0 0.4 0.6 -100 to 400 0.3 0.4 0.3 0.4 400 to 1200 0.5 0.8 0.3 0.4 1200 to 1372 0.7 1.0 0.3 0.4 T -250 to -200 1.7 2.5 0.9 1.4 -200 to 0 0.6 0.9 0.4 0.6 0 to 400 0.3 0.4 0.3 0.4 B 600 to 800 1.3 2.0 1.0 1.5 800 to 1000 1.0 1.5 0.8 1.2 1000 to 1820 0.9 1.3 0.8 1.2 R -20 to 0 2.3 2.8 1.2 1.8 0 to 100 1.5 2.2 1.1 1.7 100 to 1767 1.0 1.5 0.9 1.4 S -20 to 0 2.3 2.8 1.2 1.8 0 to 200 1.5 2.1 1.1 1.7 200 to 1400 0.9 1.4 0.9 1.4 1400 to 1767 1.1 1.7 1.0 1.5 C 0 to 800 0.6 0.9 0.6 0.9 800 to 1200 0.8 1.2 0.7 1.0 1200 to 1800 1.1 1.6 0.9 1.4 1800 to 2316 2.0 3.0 1.3 2.0 L -200 to -100 0.6 0.9 0.3 0.4 -100 to 800 0.3 0.4 0.2 0.3 800 to 900 0.5 0.8 0.2 0.3 U -200 to 0 0.6 0.9 0.4 0.6 0 to 600 0.3 0.4 0.3 0.4 BP 0 to 1000 1.0 1.5 0.4 0.6 1000 to 2000 1.6 2.4 0.6 0.9 2000 to 2500 2.0 3.0 0.8 1.2 XK -200 to 300 0.2 0.3 0.2 0.5 300 to 800 0.4 0.6 0.3 0.6 -
-
Models
Model Name Description Fluke 754 Fluke 754 Documenting Process Calibrator-HART Includes:
- BC7240 battery charger
- Li-on BP7240 battery pack
- DPCTrack 2™ Sample Software
- Instruction manual
- NIST-traceable calibration report and data
- Three sets of TP220 test probes with three sets of “extended tooth" alligator clips
- Two sets AC280 hook clips
- C799 Soft Field Case
- USB communication cable, Fluke 754HHC HART communications cable
-
-
-
Batteries, Chargers & Adapters
Model Name Description Fluke BC7240 Fluke BC7240 Battery charger/Eliminator for 75x Fluke BP7240 Fluke BP7240 Li-Ion Battery Pack for 75x -
Cases & Holsters
Model Name Description Fluke C700 Fluke C700 Hard Carrying Case Fluke Store Fluke C781 Fluke C781 Meter Case Fluke Store -
Clips
Model Name Description Fluke AC220 Fluke AC220 SureGripTM Alligator Clips Fluke Store Fluke AC280 Fluke AC280 SureGripTM Hook Clips Fluke Store Fluke AC285 Fluke AC285 SureGripTM Alligator Clips Fluke Store -
Pressure Calibration Kit
Model Name Description Fluke 700PCK Fluke 700PCK Pressure Calibration Kit -
Pumps & Accessories
Model Name Description Fluke 700PMP Fluke 700 PMP Pressure Pump Fluke Store Fluke 700HTH-1 Fluke 700HTH-1 Hydraulic Test Hose Fluke 700HTP 2 Fluke 700HTP-2 Hydraulic Test Pump Fluke 700PRV-1 Fluke 700PRV-1 Pressure Relief Valve Kit Fluke Store Fluke 700PTP-1 Fluke 700PTP-1 Pneumatic Test Pump Fluke Store -
Software
Model Name Description Fluke 750SW Fluke 750 SW DPC/TRACK2 Software -
Temperature Accessories
Model Name Description Fluke 80CJ M Fluke 80CJ-M type J Male Mini-Connectors Fluke Store Fluke 80CK M Fluke 80CK-M type K Male Mini-Connectors Fluke Store Fluke 80PJ-1 Fluke 80PJ-1 Bead Probe Fluke Store Fluke 80PJ-EXT Fluke 80PJ-EXT Extension Wire Kit Fluke Store Fluke 80PK 1 Fluke 80PK-1 Bead Probe Fluke Store Fluke 80PK 22 Fluke 80PK-22 SureGripTM Immersion Temperature Probe Fluke Store Fluke 80PK 24 Fluke 80PK-24 SureGripTM Air Temperature Probe Fluke Store Fluke 80PK 25 Fluke 80PK-25 SureGripTM Piercing Temperature Probe Fluke Store Fluke 80PK 26 Fluke 80PK-26 SureGripTM Tapered Temperature Probe Fluke Store Fluke 80PK 27 Fluke 80PK-27 SureGripTM Industrial Surface Temperature Probe Fluke Store Fluke 80PK 8 Fluke 80PK-8 Pipe Clamp Temperature Probe Fluke Store Fluke 80PK-9 Fluke 80PK-9 General Purpose Probe Fluke Store Fluke 80PK Fluke 80PK-EXT Extension Wire Kit Fluke Store Fluke 80PT 25 Fluke 80PT-25 SureGripTM Piercing Temperature Probe Fluke Store -
Test Leads
Model Name Description Fluke TL940 Fluke TL940 Mini-Hook Test Leads Fluke Store Fluke TL950 Fluke TL950 Mini-Pincer Test Leads Fluke Store -
Test Probes
Model Name Description Fluke TP74 Fluke TP74 Lantern Tip Test Probes Fluke Store Fluke TP920 Fluke TP920 Test Probe Adapter Set Fluke Store -
Related Products
Model Name Description Fluke 750P Fluke 750P Series Pressure Modules Fluke 753 Fluke 753 Documenting Process Calibrator Fluke 726 Fluke 726 Precision Multifunction Process Calibrator Fluke 725 Fluke 725 Multifunction Process Calibrator Fluke 721 Fluke 721 Precision Pressure Calibrator Fluke 719Pro Fluke 719Pro Electric Pressure Calibrator Fluke 719 Fluke 719 Pressure Calibrator Fluke 718 Fluke 718 Pressure Calibrator Fluke 717 Fluke 717 Pressure Calibrator
-
-
-
Manuals
Title 753/754 用户手册 Download 753/754 Users Manual Download 753/754 Mode d'emploi Download 753/754 Bedienungshandbuch Download 753/754 Manuale per l’uso Download 753/754 ユーザーズ・マニュアル Download 753/754 사용자 설명서 Download 753/754 Manual do usuário Download 753/754 Руководство пользователяl Download 753/754 Manual de uso Download 753/754 Users Manual Supplement Download DPC/TRACK Users Manual Download DPCTrack2 Users Manual Download 753/754 Calibration Manual Download 753/754 Calibration Manual Supplement Download 753/754 入门 Download 753/754 Getting Started Download 753/754 Mise en route Download 753/754 Getting Started Download 753/754 Come iniziare Download 753/754 Getting Started Download 753/754 Getting Started Download 753/754 Iniciação Download 753/754 Getting Started Download 753/754 Puesta en funcionamiento Download 753/754 Statement of Memory Volatility Download 754 Hart 用户指南 Download 754 Hart Users Guide Download 754 Hart Guide utilisateurs Download 754 Hart Benutzeranleitung Download 754 Hart Guida dell’utente Download 754 Hart Users Guide Download 754 Hart 사용 설명서 Download 754 Hart Guia do usuário Download 754 Hart Руководство пользователя Download 754 Hart Guía de uso Download 754/754 CE Declaration of Conformity Download 75X EL Instruction Sheet Download DPC/TRACK Installation Guide Download DPC/TRACK Guide d’installation Download DPC/TRACK Installationsanleitung Download DPC/TRACK Guida all'installazione Download DPC/TRACK Guía de instalación Download DPCTrack2 Getting Started Download -
Application Notes
Title Automated field calibration for the oil and gas industry Download Calibrating pressure switches with a DPC application note Download Fluke 753/754 Windows Driver Downloads Download HART transmitter calibration application note Download Testing temperature switches with a Fluke documenting process calibrator application note Download Transmitter calibration Download Using the 754 with a dry block calibrator, eliminate temperature sensor errors in loop calibrations application note Download Using the Fluke 726 and custom RTD constants for precision temperature measurement Download -
Brochures
-
Data Sheets
Title Fluke 750 Data Sheet Download
-


