Keeping your world up and running.®

Fluke 718Ex Intrinsically Safe Pressure Calibrator

The Fluke 718Ex is a powerful intrinsically safe self-contained portable pressure calibrator for usage in explosion endangered areas.

See All Models »
Overview
Features
Reviews
Specs
Models/Accessories
Resources
  • Pump Up the Pressure

    The Fluke 718Ex Intrinsically Safe Pressure Calibrator is a powerful intrinsically safe, self contained pressure calibrator for usage in explosion endangered areas.

    • ATEX II 1G Ex ia IIC T4 Compliant.
    • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
    • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
    • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
    • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
    • Wide range of selectable measurement units for pressure.
    • Current measurement with 0.02% accuracy and 0.001 mA resolution.
    • Pressure switch test function.
    • Min-Max Hold functions.
    • Compact size and weight.
    • Simple, push-button user interface.
    • Rugged and reliable, ideal for field use.
  • Pressure Measurement Accuracy
    Fluke 718Ex 30G Range -830 mbar to 2 bar (internal sensor)
    Over pressure: 3x FS
    Resolution 0.0001 bar
    Accuracy 0.05% FS
    Functions Zero, Min, Max, Hold, Damp
    Fluke 718Ex 100G Range -830 mbar to 2 bar (internal sensor)
    Over pressure: 2x FS
    Resolution 0.001 bar
    Accuracy 0.05% FS
    Functions Zero, Min, Max, Hold, Damp
    Fluke 718Ex 300G Range -830 mbar to 20 bar (internal sensor)
    Over pressure: 375 psi, 25 bar
    Resolution 0.0001 bar
    Accuracy 0.05% FS
    Functions Zero, Min, Max, Hold, Damp
    Fluke 718Ex series Range Via pressure module connector
    29 pressure modules, 2.5 mbar to 700 bar
    Over pressure per pressure module specs
    Resolution Per pressure module specs
    Accuracy To 0.025% of full span, per pressure module specs
    Functions Zero, Min, Max, Hold, Damp
    Source pressure, built in pump range -820 mbar to full scale
    For use with non-corrosive gasses.
    Supported Pressure Units psi, inH2O (4°C), inH2O (20°C), kPa, cmH2O (4°C), cmH2O (20°C), bar, mbar, kg/cm², mmHg, inHg
    Media compatibility per pressure module specs
    Technical Data
    Measure accuracy Range 0-24 mA
    Resolution 0.001 mA
    Accuracy 0.02% rdg ±2 counts
    Display LCD, 5 digit pressure and current simultaneous
    Environmental Specifications
    Operating temperature -10°C to 55°C
    Storage temperature -40°C to 60°C
    Humidity (without condensation) 95% (10°C to 30°C)
    75% (30°C to 40°C)
    45% (40°C to 50°C)
    35% (50°C to 55°C)
    Operating altitude 3,000 m max
    Safety Specifications
    Safety ATEX II 1G Ex ia IIC T4 compliant
    CSA Certification I.S. Class I
    Div 1 Groups A-D , T4
    Mechanical and General Specifications
    Size (L x W x H) 216 x 94 x 66 mm (with holster)
    Weight Approx. 992 g (with holster)
    Warranty Three years, one year for pump
    Shock 1 meter drop test
    Vibration Random, 2 G, 5-500 Hz
    Battery type One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V
    Battery life 4 to 20 hours, depending on functions used
    • Models
      Model Name Description  
      Fluke 718Ex 30G Fluke 718Ex 30G Intrinsically Safe Pressure Calibrator
      30 psi
       

      Includes:

      • Protective red holster
      • TL75 test leads
      • AC72 test clips
      • CD users manuals (English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish, Finnish, Portuguese, Korean, Chinese, Japanese)
      • Fluke 718Ex CCD content control drawing
      • NIST- traceable calibration report and dat
      Fluke 718EX 100G Fluke 718Ex 100G Intrinsically Safe Pressure Calibrator
      100 psi
       

      Includes:

      • Protective red holster
      • TL75 test leads
      • AC72 test clips
      • CD users manuals (English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish, Finnish, Portuguese, Korean, Chinese, Japanese)
      • Fluke 718Ex CCD content control drawing
      • NIST- traceable calibration report and data
      Fluke 718EX 300G Fluke 718Ex 300G Intrinsically Safe Pressure Calibrator
      300 psi
       

      Includes:

      • Protective red holster
      • TL75 test leads
      • AC72 test clips
      • CD users manuals (English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish, Finnish, Portuguese, Korean, Chinese, Japanese)
      • Fluke 718Ex CCD content control drawing
      • NIST- traceable calibration report and dat
    • Clips
      Model Name Description  
      Fluke AC72 Fluke AC72 Alligator Clip Set
    • Intrinsically Safe (Ex) Modules
      Model Name Description  
      Fluke 700P01EX Fluke 700P01Ex Differential Pressure Module
      Fluke 700P05EX Fluke 700P05Ex Gauge Pressure
      Fluke 700P06EX Fluke 700P06Ex Gauge Pressure
      Fluke 700P09EX Fluke 700P09Ex Gauge Pressure
      Fluke 700P24EX Fluke 700P24Ex Differential Pressure Module Wet
      Fluke 700P27EX Fluke 700P27Ex Gauge Pressure Module
      Fluke 700P29EX Fluke 700P29Ex Gauge Pressure Module
    • Pressure Modules, Absolute
      Model Name Description  
      Fluke 700PA4EX Fluke 700PA4Ex Absolute Pressure Module
    • Pumps & Accessories
      Model Name Description  
      Fluke 700HTH-1 Fluke 700HTH-1 Hydraulic Test Hose
    • Test Leads
      Model Name Description  
      Fluke TL238 Fluke TL238 SureGripTM Test Lead Set for High Energy Environments Fluke Store
      Fluke TL75 Fluke TL75 Hard PointTM Test Lead Set Fluke Store
    • Manuals
      Title  
      718Ex Control Drawing Download
      718Ex Control Drawing Supplement Download
      718Ex Users Manual Download
      718Ex User's Manual Supplement Download
      700PEx Instruction Sheet Download
      700PEx Instruction Sheet Supplement Download
      718Ex 30/100G Safety Sheet Download
      718Ex 30/100G Safety Sheet Supplement Download
      718Ex Bedienungshandbuch Download
      718Ex Manual do usuário Download
      718Ex Käyttöohje Download
      718Ex Mode d'emploi Download
      718Ex Användarhandbok Download
      718Ex 用户手册 Download
      718Ex Brugsanvisning Download
      718Ex Handleiding Download
      718Ex Manuale per l’uso Download
      718Ex ユーザーズ・マニュアル Download
      718Ex Manual de uso Download
      700PEx 사용설명서 Download
      700PEx Instruksjonsark Download
      700PEx 使用说明单 Download
      700PEx Brugsanvisning Download
      700PEx Instructieblad Download
      700PEx Anleitungsblatt Download
      700PEx Foglio di istruzioni Download
      700PEx Folha de instruções Download
      700PEx 使用説明書 Download
      700PEx Ohjelehti Download
      700PEx Fiche d´instruction Download
      700PEx Anvisningsblad Download
      700PEx Hoja de instrucciones Download
      718Ex 30/100G 안전정보 Download
      718Ex 30/100G Sikkerhetsdatablad Download
      718Ex 30/100G 安全数据单 Download
      718Ex 30/100G Sikkerhedsblad Download
      718Ex 30/100G Veiligheidsinformatieblad Download
      718Ex 30/100G Sicherheitsdatenblatt Download
      718Ex 30/100G Foglio delle informazioni di sicurezza Download
      718Ex 30/100G Folha de Segurança Download
      718Ex 30/100G Safety Sheet Download
      718Ex 30/100G Turvaohjeet Download
      718Ex 30/100G Fiche de sécurité Download
      718Ex 30/100G Säkerhetsdatablad Download
      718Ex 30/100G Hoja de seguridad Download
    • Brochures
      Title  
      Intrinsically Safe Brochure Download
    • Application Notes
      Title  
      Troubleshooting 4-20 mA process control systems without breaking the loop Download
      Transmitter calibration Download
      HART transmitter calibration application note Download
      Using the 754 with a dry block calibrator, eliminate temperature sensor errors in loop calibrations application note Download
      Calibrating pressure switches with a DPC application note Download
      Breaking new ground without breaking the loop Download
      Better ways to troubleshoot automation and process control loops Download
      Loop calibration and maintenance application note Download
    • Data Sheets
      Title  
      Intrinsically Safe Fluke 718Ex 30G, 100G, and 300G Pressure Calibrators Download
      Loop Calibrators Data Sheet Download