Includes the 1587 FC 2-in-1 Insulation DMM and the i400 Current Clamp
The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app:
- Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
- Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
- Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
- Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets
The Fluke i400 AC Current Clamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.
-
Includes the Fluke 1587 FC 2-in-1 Insulation DMM and the Fluke i400 Current Clamp
- With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
- Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit
The Fluke 1587 FC 2-in1 Insulation DMM
- Pl/DAR measurements with TrendIt™ graphs
- Memory storage through Fluke Connect Measurements app
- Temperature Compensation through Fluke Connect Measurements app
- VFD low-pass filter for accurate motor drive measurements
- Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
- Insulation test voltages 500 V, 1000 V
- Insulation test: 0.01 MΩ to 2.0 GΩ
- Insulation test: 0.1 MΩ to 600 MΩ
- Auto-discharge of capacitive voltage
- Insulation test smoothing reading
- Frequency / Capacitance / Diode test / Temperature
- Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
- Resistance (0.1 Ω to 50 MΩ) / Continuity / Auto power off
- Three-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case
- Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
- 1 mA/Amp output guarantees easy reading
- CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
- Specially designed to offer maximum utility in a very compact shape
- Maximum conductor: Ø 32 mm
- 1 year warranty
-
Fluke 1587 FC Insulation Multimeter
Electrical Specifications AC voltage measurement Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹ 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹ ¹ 1 kHz bandwidth Low-Pass Filter Voltage Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) DC Voltage Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 6.000 V dc 0.001 V ±(0.09% + 2) 60.00 V dc 0.01 V ±(0.09% + 2) 600.0 V dc 0.1 V ±(0.09% + 2) 1000 V dc 1 V ±(0.09% + 2) Input impedance 10 MΩ (nominal), <100 pF Normal mode rejection ratio >60 dB @ 50 Hz or 60 Hz Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) Accuracies apply to ± 100% of range DC Millivolts Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 600.0 mVdc 0.1 mV ±(0.1% + 1) DC and AC Current Measurement AC 45 Hz to 1000 Hz Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ Burden voltage (Typical) 2 mV/mA DC Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Overload 600 mA for 2 minutes maximum Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3. ¹ 1 kHz bandwidth Ohms Measurement Range Resolution Accuracy +(% of Rdg+Counts)¹ 600.0 Ω 0.1 Ω ±(0.9% + 2) 6.000 kΩ 0.001 kΩ ±(0.9% + 2) 60.00 kΩ 0.01 kΩ ±(0.9% + 2) 600.0 kΩ 0.1 KΩ ±(0.9% + 2) 6.000 MΩ 0.001 MΩ ±(0.9% + 2) 50.0 MΩ ² 0.01 MΩ ±(1.5% + 3) Overload protection 1000 V rms or dc Open circuit test voltage <8.0 V dc Short circuit current <1.1 mA ¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidityDiode Test Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current: Accuracy ±(2% + 3) Continuity Test Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω Open circuit voltage <8.0 V Short circuit current 1.0 mA typical Overload protection 1000 V rms Response time >1 m sec Frequency Measurement Range Resolution Accuracy ±(% of Rdg+Counts) 99.99 Hz 0.01 Hz ±(0.1% + 1) 999.9 Hz 0.1 Hz ±(0.1% + 1) 9.999 kHz 0.001 kHz ±(0.1% + 1) 99.99 kHz 0.01 kHz ±(0.1% + 1) Frequency Counter Sensitivity 600.0 mV ac V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 mV V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 150.0 mV DC Trigger Levels¹ to 20 kHz² NA 6.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 1.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 1.5 V DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V 60.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 10.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 36.0 V DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V 600.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz - DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V 1000.0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 300.0 V V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz - DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale inputCapacitance Range Resolution Accuracy ±(% of Rdg+Counts) 1000 nF 1 nF ±(1.2% + 2) 10.00 μF 0.01 μF ±(1.2% + 2) 100.0 μF 0.1 μF ±(1.2% ±90 counts) 9999 μF 1 μF ±(1.2% ±90 counts) Temperature Measurement Range Resolution Accuracy ±(% of Rdg+Counts)¹ -40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts) -40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts) ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument Insulation Specifications Measurement range 0.01 MΩ to 2 GΩ Test voltages 50, 100, 250, 500, 1000 V Test voltage accuracy +20%, -0% Short-circuit test current 1 mA nominal Auto discharge Discharge time <0.5 second for C = 1 μF or less Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test Maximum capacitive load Operable with up to 1 μF load Output Voltage 50 V (0% to +20%) Display range 0.01 to 6.00 MΩ Resolution 0.01 MΩ Test current 1 mA @ 50 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 6.0 to 50.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 50 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) 100 V (0% to +20%) Display range 0.01 to 6.00 MΩ Resolution 0.01 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 6.0 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 60 to 100 MΩ Resolution 1 MΩ Test current 1 mA @ 100 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) 250 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 250 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 250 MΩ Resolution 1 MΩ Test current 1 mA @ 250 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) 500 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 500 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 500 MΩ Resolution 1 MΩ Test current 1 mA @ 500 kΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) 1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ Resolution 0.1 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 600 MΩ Resolution 1 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 0.6 to 2.0 GΩ Resolution 100 MΩ Test current 1 mA @ 1 MΩ Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts) General Specifications Maximum voltage applied to any terminal and common 1000 V Storage temperature -40 °C to 60 °C (-40 °F to 140 °F) Operating temperature -20 °C to 55 °C (-4 °F to 131 °F) Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F) Relative humidity Noncondensing 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F) 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F) 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F) Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument Radio frequency communication 2.4 GHz ISM Band Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE Electromagnetic Compatibility International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Enclosure protection IEC 60529: IP40 (non-operating) Safety IEC 61010-1 Pollution Degree 2 IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V Batteries Four AA batteries (NEDA 15A or IEC LR6) Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) Weight 550 g (1.2 lb) Altitude Operating 2000 m Storage 12,000 m Over-range capability 110% of range except for capacitance which is 100% Frequency overload protection <107 V Hz Fuse protection for mA input 0.44A, 1000 V, IR 10 kA Fluke i400 AC Current Clamp
Specifications Nominal current range 400 A Continuous current range 1 A - 400 A Maximum non-destructive current 1000 A Lowest measurable current 1 A Basic accuracy 2% + 0.06 A (45-400 Hz) (% reading + floorspec) Useable frequency 5 Hz - 20 kHz Output level(s) 1 mA/A Safety Specifications Safety CAT IV 600 V, CAT III, 1000 V Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010 Mechanical and General Specifications Warranty 1 year Maximum conductor diameter 32 mm (1.25 in) Maximum conductor size (busbar) 750 MCM Output cable length 1.5 m (59 in) Shrouded banana plugs Yes -
-
Models
Model Name Description FLK-1587/i400 FC Kit Fluke 1587/i400 Current Clamp FC Kit Includes:
- Fluke 1587 FC 2-in-1 Insulation DMM
- Fluke i400 Current Clamp
-
-
-
Cases & Holsters
Model Name Description Fluke C25 Fluke C25 Large Soft Case for DMMs Fluke Store Fluke TPAK Fluke TPAK ToolPakTM Magnetic Meter Hanger Fluke Store -
Current Clamps
Model Name Description Fluke i400 Fluke i400 AC Current Clamp Fluke Store
-
-
-
Manuals
Title 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Download 1587 FC/1587/1577 Users Manual Supplement Download 1587 FC/1587/1577 Calibration Manual Download 1587 FC/1587/1577 Calibration Manual Supplement Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Download 1587 FC/1587/1577 Safety Sheet Supplement Download 1587 FC/1587/1587 Quick Reference Guide Download -
Brochures
Title Insulation Resistance Testing Download -
Data Sheets
Title 1587 FC Insulation Multimeter Data Sheet Download -
Download the App
-
Related Links
-