Keeping your world up and running.®

Ti95 Fluke Connect FCA Kit

Ti95 Infrared Camera, 3000 FC DMM, and a3001 FC iFlex® Module

Contact me
Ti95 Fluke Connect FCA kit
  • Ti95 Fluke Connect FCA kit
  • Fluke Tools and Fluke Connect® Assets - all your data in one place
  • Fluke Connect® Asset Analysis showing current and thermal imaging
  • Ti95 Fluke Connect
Overview
Features
Reviews
Specs
Models
Accessories
Resources
  • Fluke Connect®

    See How It Works »
    Fluke Connect FAQs »

    Troubleshooting just got easier with the Ti95 Fluke Connect FCA Kit with Ti95 Infrared Camera, 3000 FC DMM, and a3001 FC iFlex® Module. This kit features the only wireless industrial infrared camera in its price class1, the Ti95. Safely capture AC current measurements with your a3001 FC iFlex Module from up to 20 meters away on the 3000 FC DMM, while simultaneously conducting an infrared inspection with your Ti95 infrared camera. Upload your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect.

    1 Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.

  • The Fluke Ti95 Infrared Camera offers:

    • The only wireless industrial infrared camera in its price class1 – take advantage of the benefits of Fluke Connect™ by seamlessly gathering and sharing inspection results instantly
    • Superior image quality, up to 23% better spatial resolution than other competitive models in this price class1
    • 80x80 resolution
    • Removable 8 GB SD Memory Card
    • 8 GB Fluke Connect™ wireless SD Card
    • Find potential problems faster and easier with IR-Fusion® picture-in-picture mode
    • 2 megapixel built-in digital camera
    • Large 3.5 inch LCD - 32% larger screen than other competitive models lets you clearly see what you are measuring
    • Smart Battery System - Lithium ion smart battery pack with five-segment LED display to show charge level
    • Rugged, lightweight, point–and–shoot infrared camera

    The Fluke 3000 FC Series Wireless Multimeter offers:

    • AC and DC voltage measurements to 1000V
    • AC and DC current with 0.01 mA resolution
    • Continuity, resistance, diode test, capacitance and frequency measurements
    • MIN/MAX recording
    • CAT III 1000 V, Cat IV 600 V; IP54

    The Fluke a3001 FC Wireless iFlex™ AC Current Module offers:

    • One (1) true-RMS flexible current meter
    • One (1) iFlex i2500-10 flexible current probe
    • Measure up to 2500 A AC
    • Use as a standalone meter or as part of the system
    • Logging function for recording and saving up to 65,000 readings
    • Inrush function
    • Magnetic hanging strap

    1 Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.

  • Fluke Ti95 Infrared Camera

    Key Features
    IFOV (spatial resolution) 5.6 mRad
    Resolution 80 x 80 (6,400 pixels)
    Field of view 26° H x 26° V
    Wireless connectivity Yes
    Fluke Connect™ app compatible Yes, with included wireless SD card (where available)
    IR-Fusion® technology PIP (46 cm (18 in) and beyond)
    Focus system Fixed focus 46 cm (18 in) and beyond
    Ruggedized display 3.5 inch diagonal (portrait format)
    Rugged, ergonomic design for one-handed use Yes
    Thermal sensitivity (NETD) ≤ 0.10°C at 30°C target temp (100 mK)
    Temperature measurement range (not calibrated below -10°C) -20°C to +250°C (-4°F to +482°F)
    Level and span Smooth auto and manual scaling
    Fast auto toggle between manual and auto modes Yes
    Fast auto-rescale in manual mode Yes
    Minimum span (in manual mode) 2.5°C
    Minimum span (in auto mode) 5°C
    Built-in digital camera (visible light) 2 megapixel industrial performance
    Frame rate 9 Hz only
    Data Storage and Image Capture
    Extensive SD memory system Removable 8 GB SD memory card and 8 GB wireless SD card (where available)
    Direct download via USB-to-PC connection
    Image capture, review, save mechanism One-handed image capture, review, and save capability
    File formats image Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
    No analysis software required for non-radiometric (.bmp, .jpg) files
    Memory review Thumbnail view navigation and review selection
    Software SmartView® software, Fluke Connect™, and SmartView® Mobile app - full analysis and reporting software
    Export file formats with SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
    Battery
    Batteries (field-replaceable, rechargeable) One lithium ion smart battery pack with five-segment LED display to show charge level
    Battery life Four+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage)
    Battery charge time 2.5 hours to full charge
    AC battery charging system In-imager charging. AC mains adapters included in 9 Hz versions. Optional two-bay AC battery charger (110 VAC to 220 VAC, 50/60 Hz) or optional 12 V automotive charging adapter.
    AC operation AC operation with included power supply (110 VAC to 220 VAC, 50/60 Hz). AC mains adapters included.
    Power saving User selectable sleep and power off modes
    Temperature Measurement
    Accuracy ±2°C or 2% (at 25°C nominal, whichever is greater)
    On-screen emissivity correction Yes (both number and table)
    On-screen reflected background temperature compensation Yes
    Color Palettes
    Standard palettes 6: Ironbow, blue-red, high-contrast, amber, hot metal, grayscale
    General Specifications
    Infrared spectral band 9 μm to 15 μm (long wave)
    Operating temperature -10°C to +50°C (14°F to 122°F)
    Storage temperature -20°C to +50°C (-4°F to 122°F)
    Relative humidity 10% to 95%, non-condensing
    Center-point temperature measurement Yes
    Spot markers Hot and cold spot markers
    Center box (MIN-MAX-AVG) Fixed-size measurement box with MIN-MAX-AVG temp
    Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
    Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
    C Tick IEC/EN 61326-1
    US FCC EN61326-1; FCC Part 5
    Vibration 2G, IEC 68-2-6
    Shock 25G, IEC 68-2-29
    Drop Engineered to withstand 2 meter (6.5 feet) drop
    Size (H x W x L) 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
    Weight (battery included) 0.726 kg (1.6 lb)
    Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
    Warranty Two-years (standard), extended warranties are available
    Recommended calibration cycle Two-years (assumes normal operation and normal aging)
    Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

    Fluke 3000 FC Wireless Multimeter

    * For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).

    Detailed Specifications
    AC Voltage
    Range ¹ / Resolution 600.0 mV / 0.1 mV
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 2 3 4 45 Hz to 500 Hz 1.0 % + 3
    500 Hz to 1 kHz 2.0% + 3
    1. All AC voltage ranges are specified from 1 % of range to 100 % of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    Function
    mV Range / Resolution 600.0 mV / 0.1 mV
    Accuracy 0.09% + 2
    V Range / Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 0.09% + 2
    0.15% + 2
    ))) Range / Resolution 600 Ω / 1 Ω
    Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Range / Resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    60.00 kΩ / 0.1 kΩ
    600.0 kΩ / 0.001 MΩ
    50.00 MΩ / 0.01 MΩ
    Accuracy 0.5% + 2
    0.5% + 1
    1.5% + 3
    Diode test Range / Resolution 2.000 V / 0.001 V
    Accuracy 1% + 2
    µF
    Range / Resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF1 / 1 μF
    Accuracy 1.2% + 2
    10% typical
    1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    Function
    mA AC
    (45 Hz to 1 kHz)
    Range 1 / Resolution 60.00 mA / 0.01 mA
    400.0 mA 3/ 0.1 mA
    Accuracy 1.5% + 3
    mA DC 2 Range 1 / Resolution 60.00 mA / 0.01 mA
    400.0 mA 3/ 0.1 mA
    Accuracy 0.5% + 3
    1. All AC current ranges are specified from 5 % of range to 100% of range.
    2. Input burden voltage (typical): 400 mA input 2 mV/mA.
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range / Resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 kHz
    99.99 kHz / 0.01 kHz
    Accuracy 1 0.1% + 1
    1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Function Overload
    protection
    Input impedance
    (nominal)
    Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection
    1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
    1100 Vrms > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz > 60 dB at 50 Hz or 60 Hz
    1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
    Open circuit test voltage Full scale voltage Typical short circuit current
    To 6 MΩ 50 MΩ Typical short circuit current
    1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA
    1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
    mA Function
    Overload protection Fused, 44/100 A, 1000 V FAST Fuse
    Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording Accuracy
    DC functions The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
    AC functions The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate 4/sec
    Volts, amps, ohms 6000 counts
    Frequency 10,000 counts
    Capacitance 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
    Temperature Operating -10°C to 50°C
    Storage -40°C to 60°C
    Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Relative humidity 0% to 90% (0°C to 35°C)
    0% to 75% (35°C to 40°C)
    0% to 45% (40°C to 50°C)
    Altitude Operating 2,000 m
    Storage 12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008,
    FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    UL 61010-1: 3rd edition
    IEC/EN 61010-1:2010
    Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    Weight 340 g (12 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools

    Fluke a3001 FC Wireless iFlex® AC Current Module

    Specifications
    Range 0.5 A to 2500 A AC
    Resolution 0.1 A
    Accuracy 3% ±5 digits (5 Hz to 500 Hz)
    Crest factor (50 Hz / 60 Hz) 3.0 at 1100 A
    2.5 at 1400 A
    1.42 at 2500 A
    add 2% for C.F. > 2
    LCD w/backlight 3½ digits
    Log rate/interval 1 sec minimum/adjustable by PC or front panel
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Operating humidity 90% at 35°C
    75% at 40°C
    45% at 50°C
    Altitude Operating
    2,000 m
    Storage 12,000 m
    EMC EN 61326-1:2006
    Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Pollution Degree 2
    Jaw opening 25.4 cm (10 in) coil
    Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
    Weight .22 kg (8 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools
    • Models
      Model Name Description  
      FLK-Ti95 9HZ/FCA FLK-Ti95 9HZ/FCA
       

      Includes:

        Fluke Ti95 Thermal Imager:
      • AC power adapter
      • Lithium ion smart battery (1)
      • USB cable
      • SD memory card
      • Fluke Connect™ wireless SD Card (where available, shipped separately in non-European countries)
      • Soft transport bag
      • Adjustable hand strap (left- or right-handed use)
      • Printed users' manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD
      • SmartView® software
      • Warranty registration card

      Fluke 3000 FC Wireless Digital Multimeter with three AA batteries - installed:
      • TL175 Test Leads (1 pair)
      • AC175 Alligator Clips (1 pair)
      • C3003 3-compartment soft case
      • Information pack

      Fluke a3001 FC Wireless iFlex AC Current Module with two AA batteries - installed:
      • iFlex 10" coil (1)
      • Magnet/strap (1)
    • CarePlans
      Model Name Description  
      Fluke Infrared Camera Products Fluke Infrared Camera Products CarePlans Fluke Store
    • Wireless Accessories
      Model Name Description  
      FLK-FC-SD CARD Fluke Connect Wireless SD Card
    • Related Products
      Model Name Description  
      FLK-A3004 FC Fluke a3004 FC Wireless 4-20 mA DC Clamp Meter
      FLK-A3003 FC Fluke a3003 FC Wireless 2000 A DC Current Clamp Meter
      FLK-Ti400 Fluke Ti400 Infrared Camera
      FLK-Ti200 Fluke Ti200 Infrared Camera
      FLK-Ti300 Fluke Ti300 Infrared Camera
      FLK-3000 FC Fluke 3000 FC Series Wireless Multimeter
      FLK-A3000 FC Fluke a3000 FC Wireless AC Current Clamp Module
      FLK-A3001 FC Fluke a3001 FC Wireless iFlex® AC Current Module
      FLK-A3002 FC Fluke a3002 FC Wireless AC/DC Current Module
      FLK-3000 FC GM Fluke 3000 FC General Maintenance System
      FLK-3000 FC HVAC Fluke 3000 FC HVAC System
      FLK-3000 FC IND Fluke 3000 FC Industrial System
      FLK-A3000 FC Kit Fluke a3000 FC Wireless AC Current Clamp Kit
      FLK-A3001 FC Kit Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
      FLK-T3000 FC Fluke t3000 FC Wireless Temperature Module
      FLK-V3000 FC Fluke v3000 FC Wireless AC Voltage Module
      FLK-V3000 FC Kit Fluke v3000 FC Wireless AC Voltage Kit
      FLK-V3001 FC Fluke v3001 FC Wireless DC Voltage Module
      FLK-T3000 FC Kit Fluke t3000 FC Wireless Temperature Kit
      FLK-V3001 FC Kit Fluke v3001 FC Wireless DC Voltage Kit
      FLK-V3003 FC Kit Fluke v3003 FC Wireless AC-DC Voltage Measurement Kit
      Fluke-789 FC/t3000 Fluke 789 FC ProcessMeterTM and Temperature Kit
      Fluke 287 Kit Fluke 287 FlukeView® Forms Combo Kit
      Fluke 289 Fluke 289 True-RMS Industrial Logging Multimeter
      Fluke 289 Kit Fluke 289 FlukeView® Forms Combo Kit
      FLK-FC-SD CARD Fluke Connect Wireless SD Card
      Fluke 287 Fluke 287 True-RMS Electronics Logging Multimeter
      FLK-Ti90 Fluke Ti90 Infrared Camera
      FLK-Ti95 Fluke Ti95 Infrared Camera
      FLK-Ti95 9HZ/FCC Ti95 Fluke Connect FCC Kit
      FLK-Ti100 Fluke Ti100 General Use Infrared Camera
      FLK-Ti105 Fluke Ti105 Infrared Camera for Industrial and Commercial Applications
      FLK-Ti105 30HZ/FCA Fluke Ti105 a3001 FC iFlex® Kit
      FLK-Ti110 Fluke Ti110 Infrared Camera for Industrial and Commercial Applications
      FLK-Ti125 Fluke Ti125 Industrial-Commercial Infrared Camera
      FLK-TiR105 Fluke TiR105 Infrared Camera
      FLK-TiR110 Fluke TiR110 Building Diagnostic Infrared Camera
      FLK-TiR125 Fluke TiR125 Infrared Camera
      FLK-Ti200/FCA KIT Fluke Ti200 a3001 FC iFlex® Kit
      FLK-Ti300/FCA Kit Fluke Ti300 a3001 FC iFlex® Kit
      FLK-Ti400/FCA Kit Fluke Ti400 a3001 FC iFlex® Kit
      FLUKE-IR3000FC Fluke ir3000 FC Connector
      C3004IND Fluke C3004 Soft Case for FC Industrial System
      FLK-pc3000 FC Fluke pc3000 FC Wireless PC Adapter
    • Manuals
      Title  
      Fluke Connect Wi-Fi to Thermal Imager Quick Reference Guide Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti100, Ti125, TiR105, TiR110, TiR125 Safety Sheet Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 CE Declaration of Conformity Download
      Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Quick Reference Guide Download
      Ti90, Ti95, Ti105, Ti100, Ti110, Ti125, TiR110, TiR125 Statement of Memory Volatility Download
    • Data Sheets
      Title  
      TI Performance Series Data Sheet Download

Fluke Connect is not available in all countries.

©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

×
×
×