Keeping your world up and running.®

Fluke TiS50 Infrared Camera

Find problems fast in electrical, mechanical and building applications with the TiS50 Infrared Camera's 220x165 resolution and IR-Fusion® with AutoBlend and PIP mode.

Get a Free Demo
TiS50 Infrared Camera with Fluke Connect®
  • TiS50 Infrared Camera with Fluke Connect®
  • 220x165 Resolution thermal imager
  • Fixed focus, TiS50
  • See the details with D:S 353:1
Overview
Features
Reviews
Specs
Models
Accessories
Resources
  • Advanced troubleshooting with quality images

    Advanced troubleshooting with quality images
    • Quality images with a resolution standard at 220x165
    • Fixed focus, one handed point and shoot technology
    • Capture quality images at a distance with a D:S of 353:1
    • See more and analyze faster with IR-Fusion® blending and picture-in-picture
    • Get 33% more viewing area inspecting with a 3.5 inch, 320x240 LCD Screen
    • Know your power level – rechargeable batteries with level indicator
    • Easily pinpoint problems with a built-in laser pointer
    • Rugged and reliable

    Fluke Connect® WiFi communication from the field

    Save time and increase productivity in the field with Fluke Connect
    • Share images in real-time¹ across teams with Fluke Connect
    • Save time by creating and emailing reports from the jobsite
    • Capture multiple measurements all in one report
    • WiFi upload and free storage² with Fluke Cloud™
    • Store thousands of images with internal & external 4 GB memory

    Fluke SmartView® IR Analysis Reporting Software

    Fluke SmartView<sup>®</sup> IR Analysis Reporting Software<
    • Optimize images in the most effective way with IR-Fusion® technology
    • Analyze images with graphical tools to quantify severity of problems
    • Use 3D-IR™ to view different perspectives - the ultimate analysis tool
    • Report wizard guides users through report generation – it couldn't be easier
    ¹ Within your provider's wireless service area; Fluke Connect is not available in all countries
    ² 5 GB of free storage
    • Simple, easy to use fixed focus technology
    • Quality images – 220x165 resolution (36,300 pixels)
    • D:S of 353:1
    • Temperature measurement range -20 °C to 450 °C (–4 °F to 842 °F)
    • Find problems fast with exclusive IR-Fusion® Blending and PIP mode – capture the details you need to analyze problems and clearly identify the location
    • 3.5 inch, 320x240 LCD
    • 5 megapixel industrial performance digital camera
    • Smart battery system – lithium ion smart battery with five-segment LED charge level display
    • Email and share images in real time with Fluke Connect®
    • Stores thousands of images – 4 GB internal memory and 4 GB micro SD card
  • Key Features
    IFOV (spatial resolution) 2.8 mRad
    Detector resolution 220x165
    Field of view 35.7 ° x 26.8 °
    Distance to spot 353:1
    Wireless connectivity Yes
    Fluke Connect® app compatible Yes (where available)
    IR-Fusion® Technology
    AutoBlend™ mode 5 presets (0%, 25%, 50%, 75%, 100%)
    Picture-In-Picture (PIP) 5 presets (0%, 25%, 50%, 75%, 100%)
    Focus system Fixed focus, Minimum focus distance 0.45 m (1.5 ft)
    Ruggedized display 3.5 inch (landscape) 320x240 LCD
    Rugged, ergonomic design for one-handed use Yes
    Thermal sensitivity (NETD) ≤ 0.08 °C at 30 °C target temp (80 mK)
    Temperature measurement range (not calibrated below -10 °C) -20 °C to +450 °C (–4 °F to 842 °F)
    Level and span Smooth auto and manual scaling
    Fast auto toggle between manual and auto modes Yes
    Fast auto-rescale in manual mode Yes
    Minimum span (manual mode) 2.5 °C
    Minimum span (auto mode) 5 °C
    Built-in digital camera (visible light) 5 MP
    Frame rate 9 Hz
    Laser pointer Yes
    Data storage and Image Capture
    Extensive SD memory system Internal 4 GB memory and 4 GB removable micro SD card
    Image capture, review, save mechanism One-handed image capture, review, and save capability
    Image file formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2);
    No analysis software required for non-radiometric (.bmp, .jpg) files
    Instant upload Instantly upload captured images to Fluke Connect server with the use of a WiFi connection
    Memory review Thumbnail review
    Software SmartView® software - full analysis and reporting software and Fluke Connect® (where available)
    Export file formats with SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
    Voice annotation Yes, Bluetooth Headset (sold separately)
    IR-PhotoNotes™ Yes (1 image)
    Standard video recording -
    Radiometric video recording -
    Video file formats -
    Streaming video (remote display) -
    Battery
    Batteries (field-replaceable, rechargeable) One lithium ion smart battery pack with five-segment LED display to show charge level
    Battery life Four+ hours 
    Battery charge time 2.5 hours to full charge
    Battery charging system In-imager charging (optional external charger sold separately)
    AC operation AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
    Temperature Measurement
    Accuracy ±2 °C or 2% (at 25 °C nominal, whichever is greater)
    On-screen emissivity correction Yes (both value and table)
    On-screen reflected background temperature compensation Yes
    On-screen transmission correction Yes
    Color Palettes
    Standard palettes 8: Ironbow, Blue-Red, High-Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
    Ultra Contrast™ palettes -
    General Specifications
    Color alarms (temperature alarms) High temperature, low temperature, Isotherms
    Infrared spectral band 7.5 μm to 14 μm
    Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature -20 °C to +50 °C (-4 °F to 122 °F)
    Relative humidity 10% to 95%, non-condensing
    Center-point temperature measurement Yes
    Spot temperature Yes
    User-definable spot markers 2
    Center box Expandable-contractible measurement box with MIN-MAX-AVG temp
    Safety standards EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN 60529, EN 62133 (lithium battery)
    Electromagnetic compatibility EN 61326-1:2006, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3
    C Tick IEC/EN 61326-1
    US FCC EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3
    Vibration and shock 2G, IEC 68-2-6 and 25G, IEC 68-2-29
    Drop Engineered to withstand 2 m (6.5 ft) drop
    Size (H x W x L) 26.7 x 10.1 x 14.5 cm (10.5 x 4.0 x 5.7 in)
    Weight (battery included) Fixed focus .72 kg (1.6 lb), Manual focus .77 kg (1.7 lb)
    Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
    Warranty Two-years (standard), extended warranties are available
    Recommended calibration cycle Two-years (assumes normal operation and normal aging)
    Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
    • Models
      Model Name Description  
      FLK-TiS50 Fluke TiS50 Infrared Camera
       

      Includes:

      • Thermal imager
      • AC charger/power supply with mains adapters for battery charging and AC operation
      • One rugged lithium ion smart battery
      • USB cable
      • Micro SD Card
      • Adjustable hand strap
      • Rugged, hard carrying case
      • Soft transport bag
      • Statement of factory calibration
      • Quick start guide
      • Safety sheet
    • Manuals
      Title  
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS55, TiS60, TiS65, TiS75 Users Manual Supplement Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TIS50, TiS60, TiS65, TiS75 Users Manual Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Quick Reference Guide Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Download
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Safety Sheet Supplement Download
    • Brochures
      Title  
      Compare Fluke thermal imager models Download
      Fluke Infrared Tools Brochure Download
    • Data Sheets
      Title  
      TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65, TiS75 Data Sheet Download
×
×