Keeping your world up and running.®

Fluke Ti45FT Infrared Camera

Fluke’s Ti40 and Ti45 thermal imagers feature everything needed for virtually every thermography task by delivering high resolution images where even the smallest temperature differences can be seen.

This product is discontinued or reclassified

Overview
Features
Specs
Models
Resources
  • The versatile choice for maintenance and production engineers and technicians

    The Fluke Ti4x models feature everything needed for virtually every thermography task. With a 160 x 120 detector and a temperature sensitivity down to 0.08°C (80mK) (NETD) they deliver high resolution images where even the smallest temperature differences can be seen. The units are extremely easy to use through the Windows® CE menu structure and offer an extended troubleshooting feature set to allow on the spot analysis in the field.

    The FT models feature the innovative IR-Fusion® technology. IR-Fusion captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect components and enable the repair to be done right the first time. To find out more select IR-Fusion on the side navigation of this page.

    Typical applications:

    • Predictive maintenance – Identify electrical and mechanical problems before they cause failure
    • Industrial maintenance – Check whether repairs have been performed successfully
    • Quality control – Examine prototypes and refine thermal management designs
    • Process monitoring – Real-time observation to ensure efficient and safe operation
  • Fluke IR-Fusion Technology

    Infrared and Visible light images are fused together - enabling you to view images in a range of modes from full IR to full visible light, and see exactly what you are viewing.

    See exactly what you are viewing

    Fluke IR-Fusion® technology links a real world visual image with a thermal image. It merges the two images into one, with the possibility to blend between the two images or create picture-in-picture combinations. Alarm limits can be superimposed over the visible light image to exactly pinpoint the components exceeding a specified temperature limit. Both the visual images and thermal images are available for use in reports. This speeds up documentation by reducing the need to look for individual images taken with a separate digital camera. IR Fusion helps to better identify and report suspect components and enable the repair to be done right the first time.

    Large, sharp thermal images

    Thanks to the largest display (five-inch) available on this type of thermal imager in combination with low-noise VOx sensors, the Fluke IR FlexCam units produce exceptionally high-quality images making even the smallest temperature differences visible. This is comparable with images normally only obtained on far more expensive instruments.

    A sharp image in every situation

    The innovative 180 ° articulating lens makes it possible to view and capture images in areas with poor accessibility. The display remains clearly visible while viewing over high objects, under a machine or around immoveable obstructions. The SmartFocus wheel simplifies getting a stable and sharp image. No need to take your hand off the instrument to turn a focus ring.

    Make anomalies visible

    Thanks to built-in functions like AutoCapture, the IR FlexCam Thermal Imagers help to troubleshoot difficult problems. The instrument is easily set up to automatically capture only those images where a temperature limit is exceeded. This way, difficult to find intermittent problems can be captured and analyzed quicker by concentrating only on the images containing the anomalies.

    Analysis and reporting comes standard

    The SmartView™ software (supplied with the unit) includes a complete range of infrared image viewing, analysis, annotation and reporting tools. It even allows for customized reports to accommodate specific company work processes or requirements like multiple image reporting and comparisons. To find out more select SmartView on the side navigation of this page.

    Radiometric measurement – the ‘data behind the picture’

    Fully radiometric thermal imagers capture and store calibrated temperature data for the matrix of thousands of points that make up a thermal image. This makes it possible to perform detailed analysis and change key parameters like emissivity or temperature range either in the field on the camera or in the office using the PC software.

  • Specifications
    Imaging performance Thermal  
    Field of view (FOV)* 20 mm lens 23 ° x 17 ° FOV
    10.5 mm lens 42 ° x 32 °
    54 mm lens 9° x 6°
    Spatial resolution (IFOV)* 2.60 mrad
    Min focus distance* 0.15 m
    Thermal sensitivity (NETD) Ti45: ≤0.08 °C(80 mK) at 30 °C
    Detector data acquisition / Image frequency* 30 Hz/60 Hz
    Focus SmartFocus; one finger continuous focus
    IR digital zoom 2x
    Detector type 160 x 120 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer
    Spectral band 8 µm to 14 µm
    Digital image enhancement Automatic full-time enhanced
    On-camera operating modes
    Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture
    Visible light camera 1280 x 1024 pixels, full color
    Visible light digital zoom
    2x
    Temperature measurement Calibrated temperature range 20 ˚C to 600 ˚C (-4 to 1112 ºF) in 3 ranges
    Range 1
    20 ˚C to 100 ˚C (-4 to 212 ºF)
    Range 2
    -20 ˚C to 350 ˚C (-4 to 662 ºF)
    Range 3
    250 ˚C to 600 ˚C (482 to 1112 ºF)
    Optional - High temperature Up to 1200 ˚C (2192 ºF)
    Range 4
    500 ˚C to 1200 ˚C (932 to 2192 ºF)
    Accuracy ±2°C or 2 % (whichever is greater)
    Measurement modes
    Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm above and below
    Emissivity correction 0.1 to 1.0 (0.01 increments)
    Image presentation Digital display 5" large high-resolution digital display
    LCD backlight Sunlight readable color LCD
    Video output RS170 EIA/NTSC or CCIR/PAL composite video
    Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted
    Optional lenses (only available at time of original purchase) 54 mm telephoto lens High precision Germanium lens
    Field of view (FOV) 9º horizontal x 6º vertical
    Spatial resolution (IFOV) 0.94 mrad
    Min focus distance 0.6 m
    10.5 mm wide angle lens High precision Germanium lens
    Field of view (FOV) 42 º horizontal x 32 º vertical
    Spatial resolution (IFOV) 4.9 mrad
    Min focus distance 0.3 m
    Image and data storage Storage medium Compact flash card stores over 1000 IR images (1 GB card standard)
    File formats supported 14 bit measurement data included. Exportable JPEG, BMP, PNG, GIF, TIFF.
    Interfaces and software Interface Compact flash card reader included
    Software SmartView; full analysis and reporting software included
    Laser Classification Class II
    Laser targeting Laser dot visible on screen when blending thermal and visible image
    Controls and adjustments Set-up controls Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low)
    Image controls Level, span, auto adjust (continuous/manual)
    On-screen indicators Battery status, target emissivity, background temperature and real time clock
    Power, battery life Battery type Li-Ion smart battery, rechargeable, field-replaceable
    Battery operating time 3 hours continuous operation (2 hours with IR-Fusion engaged)
    Battery charging 2 bay intelligent charger powered via AC outlet
    AC operation AC adapter 110/220 VAC, 50/60 Hz (Ti45 only)
    Power saving Automatic shutdown and sleep modes (user specified)
    Environmental and mechanical design Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature -40 °C to +70 °C (-40 °F to 158 °F)
    Relative humidity Operating and storage 10% to 95%, non-condensing
    Water and dust resistant IP54
    Weight (including batteries) 1.95 kg (4.3 lbs)
    Camera size (HxWxD) 162 x 262 x 101 mm (6.5" x 10.5" x 4.0")
    Other Warranty 2 years

    7.5 Hz models are available in some geographies. Check with your Fluke sales representative for additional information.

    • Model
      Model Name Description  
      Fluke Ti45FT-20 Fluke Ti45FT Infrared Camera
      FlexCam® Infrared Cameras with IR-Fusion® Technology

      Includes:

      • Heavy duty carrying case
      • 2 rechargeable battery packs
      • Battery charger
      • AC adapter
      • Video cable
      • 512 MB compact flash card
      • Compact flash card reader and USB cable
      • Neck strap
      • SmartView reporting and analysis software on CD
      • User manual on CD
      • Calibration certificate
    • Manuals
      Title  
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 用户手册 Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Users Manual Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Mode d'emploi Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Bedienungshandbuch Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Manuale per l’uso Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 ユーザーズ・マニュアル Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Manual do usuário Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Руководство пользователя Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Manual de uso Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Användarhandbok Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Kullanım Kılavuzu Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Users Manual Supplement Download
      SmartView 3.2.1 Help Printable Help Download
      Ti9, Ti10, Ti25, TiR, TiR1, TiRX, TiXB, TiS CE Declaration of Conformity Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 CE Declaration of Conformity Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 入门 Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Aan de slag Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Getting Started Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Mise en route Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Getting Started Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Come iniziare Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Getting Started Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Getting Started Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Getting Started Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Puesta en funcionamiento Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Komma igång Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Başlangıç Download
      TiR2,TiR3,TiR4,Ti40,Ti45,Ti50,Ti55 Statement of Memory Volatility Download
    • Application Notes
      Title  
      Conducting thermal investigations for moisture in building envelopes Download
    • Case Studies
      Title  
      Case Study: Thermal Imaging From Fluke Provides Improved Risk Management for Agricultural Policy Holders Download
    • Data Sheets
      Title  
      Ti55FT and Ti50FT FlexCam Infrared Camera Technical Data Sheet Download
×
×
×