Fluke Connect FAQs »When you combine the Ti200 thermal imaging camera, a3001 FC iFlex modules and the Fluke Connect™ App you get a powerful solution that allows you to quickly identify and diagnose problems directly from the field. Aggregate all your data from both inspections into the Fluke Connect™ app and you can instantly share your results from anywhere, with any team member, at any time. Get started saving time and increasing your productivity now.
The Ti200 is one of only three thermal cameras in the Fluke portfolio equipped with LaserSharp® Auto Focus for consistently in-focus images. Every. Single. Time. Without an in-focus image, temperature measurements may be off by as much as 20 degrees making is much easier to miss a problem. LaserSharp® Auto Focus tells you exactly where you are focusing. It uses a laser to calculate the distance to your target before it focuses. Place the red laser dot on the equipment you are inspecting, then pull and release the trigger for a perfect in-focus image. Uptime or downtime. Your Results Matter.
-
The Ti200 offers:
- Consistently in-focus images with the exclusive LaserSharp® Auto Focus system
- See the crucial details needed to help clearly identify potential problems with precisely blended visual and infrared images – only with IR Fusion® technology with AutoBlend™ mode.
- Fluke Connect™ compatible - the largest network for wirelessly enabled tools
- Faster communication with wireless image transfer directly to your PC, Apple® iPhone® or iPad®
- Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation
- Capture additional digital images to show location or additional site details with IR-PhotoNotes™ Annotation System
- More advanced display output options to get the details via streaming video to PC or high definition monitor (USB and HDMI)
- Voice recording and annotation gets additional details saved with the image file
- Optional interchangeable lenses for greater flexibility in additional applications
- Ruggedized Touchscreen Display (Capacitive) 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight for quick menu navigation
- 5 MP industrial-performance digital camera for high definition image quality
- Included SmartView® and SmartView Mobile App Analysis and Reporting Software
The 3000 FC Wireless Multimeter offers:
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V, Cat IV 600 V; IP54
The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier. The a3001 FC offers:
- One (1) true-RMS flexible current meter
- One (1) iFlex i2500-10 flexible current probe
- Measure up to 2500 A AC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
- Magnetic hanging strap
-
Fluke Ti200 Infrared Camera
Detailed Specifications Temperature Temperature measurement range
(not calibrated below -10°C)-20°C to + 650°C (-4°F to + 1202°F) Temperature measurement accuracy ± 2°C or 2% (at 25°C nominal, whichever is greater) On-screen emissivity correction Yes (by number and table) On-screen reflected background temperature compensation Yes On-screen transmission correction Yes Imaging Performance Image capture frequency 60 Hz refresh rate Detector type Focal Plane Array, uncooled microbolometer, 200 X 150 pixels Thermal sensitivity (NETD) ≤ 0.075°C at 30°C target temp (75 mK) Total pixels 30,000 Infrared spectral band 7.5 μm to 14 μm (long wave) Visual (visible light) camera Industrial performance 5.0 megapixel Standard Infrared Lens Type Field of view 24° x 17° Spatial resolution (IFOV) 2.09 mRad Minimum focus distance 15 cm (approx. 6 in) Optional Telephoto Infrared Lens Type Field of view 12° x 9° Spatial resolution (IFOV) 1.05 mRad Minimum focus distance 45 cm (approx. 18 in) Optional Wide-Angle Infrared Lens Type Field of view 46° x 34° Spatial resolution (IFOV) 4.19 mRad Minimum focus distance 15 cm (approx. 6 in) Focus Mechanism LaserSharp® Auto Focus system Yes Advanced manual focus Yes Image Presentation Palettes Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual and auto modes Yes Fast auto-rescale in manual mode Yes Minimum span (in manual mode) 2.0°C (3.6°F) Minimum span (in auto mode) 3.0°C (5.4°F) IR-Fusion® Information Picture-in-Picture (PIP) Yes Full screen infrared Yes AutoBlend™ mode Yes Color alarms (temperature alarms) High-temperature , low-temperature, and isotherm (user-selectable) Image Capture and Data Storage Image capture, review, save mechanism One-handed image capture, review, and save capability Storage medium Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp and jpg) files Export file formats w/SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF Memory review Thumbnail view navigation and review selection Other Time-Saving and Productivity Features Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager IR-PhotoNotes™ Yes WiFi connectivity Yes, to PC, iPhone®, iPad® and WiFi to LAN* Text annotation* Yes Video recording* Standard and radiometric Streaming video Via USB to PC and HDMI to HDMI compatible screen Fluke Connect compatible Yes (where available) Auto capture (temperature and interval)* Yes Remote control and operation (for special and advanced applications) No General Specifications Operating temperature -10°C to + 50°C (14°F to 122°F) Storage temperature -20°C to + 50°C (-4°F to 122°F) without batteries Relative humidity 10% to 95% non-condensing Ruggedized touchscreen display (capacitive) 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight Controls and adjustments User selectable temperature scale (°C/°F) Language selection Time/Date set Emissivity selection Reflected background temperature compensation Transmission correction User selectable hot spot and cold spot, and center point on the image Expandable-contractable Measurement Box with MIN-AVG-MAX temp Color alarms User selectable backlight setting graphical information display preference Graphical information display preference Software SmartView® and SmartView Mobile App - full analysis and reporting software included Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models Battery life Four+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage) Battery charge time 2.5 hours to full charge AC battery charging Two-bay AC battery charger (110 V AC to 220 V AC, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. AC operation AC operation with included power supply (110 V AC to 220 V AC, 50/60 Hz). AC mains adapters included. Power saving User selectable sleep and power off modes Safety standards UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010) Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005 C Tick IEC/EN 61326-1 US FCC CFR 47, Part 15 Subpart B Class B Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6 Shock 25 g, IEC 68-2-29 Drop Engineered to withstand 2 meter (6.5 feet) with standard lens Size (H x W x L) 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in) Weight (battery included) 1.04 Kg (2.3 lb) Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions) Warranty Two-years (standard), extended warranties are available. Recommended calibration cycle Two-years (assumes normal operation and normal aging) Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish *Coming soon via firmware update. Users notified via SmartView software when available. Fluke 3000 FC Series Wireless Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ± ([% of Reading ] + [ Number of least significant digits ]).
AC Voltage Range¹ / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 VAccuracy2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 kHz 2.0% + 3 1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.DC Voltage, Continuity, Resistance, Diode Test and Capacitance mV Range / resolution 600.0 mV / 0.1 mV Accuracy 0.09% + 2 V Range / resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 VAccuracy 0.09% + 2
0.15% + 2))) Range / resolution 600 Ω / 1 Ω Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. Ω Range / resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩAccuracy 0.5% + 2
0.5% + 1
1.5% + 3Diode test Range / resolution 2.000 V / 0.001 V Accuracy 1% + 2 µF Range / resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μFAccuracy 1.2% + 2
10% typical1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. AC and DC Current mA AC
(45 Hz to 1 kHz)Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mAAccuracy 1.5% + 3 mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
400.0 mA3/ 0.1 mAAccuracy 0.5% + 3 1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.Frequency Range / resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHzAccuracy1 0.1% + 1 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. Input Characteristics Overload protection 1100 V RMS Input impedance (nominal) > 10 MΩ < 100 pF Common mode rejection ratio
(1 kΩ unbalance)> 120 dB at DC, 50 Hz or 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Overload protection 1100 V RMS Input impedance (nominal) > 10 MΩ < 100 pF Common mode rejection ratio
(1 kΩ unbalance)> 60 dB, DC to 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Overload protection 1100 V RMS Input impedance (nominal) > 10 MΩ < 100 pF Common mode rejection ratio
(1 kΩ unbalance)> 120 dB at DC, 50 Hz or 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Open Circuit Test Voltage Overload protection 1100 V RMS Input impedance (nominal) < 2.7 V DC Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ< 0.7 V DC
< 0.9 V DCTypical short circuit current < 350 mA Overload protection 1100 V RMS Input impedance (nominal) < 2.7 V DC Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ2.000 V DC Typical short circuit current < 1.1 mA mA Function Overload protection Fused, 44/100 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum MIN/MAX Recording Accuracy DC functions ± 12 counts for changes > 350 mS in duration. AC functions ± 40 counts for changes > 900 mS in duration. General Specifications Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate 4/sec Volts, amps, ohms 6000 counts Frequency 10,000 counts Capacitance 1,000 counts Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life 250 hours minimum RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed Up to 20m Obstructed, sheetrock wall Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m Temperature Operating -10°C to 50°C Storage -40°C to 60°C Temperature coefficient 0.1 X (specified accuracy) /°C (< 18°C or > 28°C) Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)Altitude Operating 2,000 m Storage 12,000 m Electromagnetic compatibility
EMI, RFI, EMC, RFEN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLESafety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010Certifications CSA, FCC, CE Ingress Protection (IP) rating IP54 Pollution Degree 2 Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight 340 g (12 oz) Warranty Three years Not compatible with Fluke CNX test tools Fluke a3001 FC Wireless iFlex AC Current Module
Specifications Range 0.5 A to 2500 A AC Resolution 0.1 A Accuracy 3% ± 5 digits (5 Hz to 500 Hz) Crest factor (50 Hz/60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2LCD w/backlight 3½ digits Log rate/interval 1 sec minimum/adjustable by PC or front panel Battery type 2 AA, NEDA 15 A, IEC LR6 Battery life 400 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed Up to 20 m Obstructed, sheetrock wall Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient Add 0.1 X (specified accuracy) /°C (< 18°C or > 28°C) Operating humidity 90% at 35°C
75% at 40°C
45% at 50°CAltitude Operating
2,000 m Storage 12,000 m EMC EN 61326-1:2006 Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition Safety rating CAT IV 600 V, CAT III 1000 V Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Pollution Degree 2 Jaw opening 25.4 cm (10 in) coil Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) Weight .22 kg (8 oz) Warranty Three years Not compatible with Fluke CNX test tools -
-
Models
Model Name Description FLK-Ti200/FCA KIT Kit Fluke Ti200 a3001 FC iFlex® Kit Includes:
Ti200 Infrared Camera
- AC power supply and battery pack charger (including mains adapters)
- Two, rugged lithium ion smart battery packs
- Micro SD memory card
- USB cable
- HDMI video cable
- SmartView® software available via free download
- Rugged, hard carrying case
- Soft transport bag
- Adjustable hand strap
- Warranty registration card
- International adapter set (9 Hz only)
3000 FC Series Wireless Multimeter
- Fluke 3000 FC Wireless Digital Multimeter with three (3) AA batteries (installed)
- One (1) a3001 FC Module with two (2) AA batteries (installed)
- One (1) iFlex 10" coil
- One (1) magnet/strap
- TL175 Test Leads (1 pair)
- AC175 Alligator Clips (1 pair)
- C3003 3-compartment soft case
- Information pack
-
-
-
Batteries, Chargers & Adapters
Model Name Description Fluke TI Car Fluke Infrared Camera Car Charger Fluke TI SBP3 Fluke SBP3 Extra Battery Pack -
Thermal Imaging Accessories
Model Name Description Fluke Ti Visor 3 Fluke Ti Visor 3 Fluke TriPod 3 Fluke Tripod Mounting Accessory 3 -
Thermal Imaging Lenses
Model Name Description FLK-LENS/25MAC2 25 Micron Macro Infrared Smart Lens FLK-LENS/TELE2 2x Telephoto Infrared Smart Lens FLK-LENS/4XTELE2 4x Telephoto Infrared Smart Lens FLK-LENS/WIDE2 Wide Angle Infrared Smart Lens -
Wireless Accessories
Model Name Description FLK-FC-SD CARD Fluke Connect Wireless SD Card -
Related Products
Model Name Description FLK-A3004 FC Fluke a3004 FC Wireless 4-20 mA DC Clamp Meter FLK-A3003 FC Fluke a3003 FC Wireless 2000 A DC Current Clamp Meter FLK-3000 FC Fluke 3000 FC Series Wireless Multimeter FLK-A3000 FC Fluke a3000 FC Wireless AC Current Clamp Module FLK-A3001 FC Fluke a3001 FC Wireless iFlex® AC Current Module FLK-A3002 FC Fluke a3002 FC Wireless AC/DC Current Module FLK-3000 FC GM Fluke 3000 FC General Maintenance System FLK-3000 FC HVAC Fluke 3000 FC HVAC System FLK-3000 FC IND Fluke 3000 FC Industrial System FLK-A3000 FC Kit Fluke a3000 FC Wireless AC Current Clamp Kit FLK-A3001 FC Kit Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit FLK-T3000 FC Fluke t3000 FC Wireless Temperature Module FLK-V3000 FC Fluke v3000 FC Wireless AC Voltage Module FLK-V3000 FC Kit Fluke v3000 FC Wireless AC Voltage Kit FLK-V3001 FC Fluke v3001 FC Wireless DC Voltage Module FLK-T3000 FC Kit Fluke t3000 FC Wireless Temperature Kit FLK-V3001 FC Kit Fluke v3001 FC Wireless DC Voltage Kit FLK-V3003 FC Kit Fluke v3003 FC Wireless AC-DC Voltage Measurement Kit Fluke-789 FC/t3000 Fluke 789 FC ProcessMeterTM and Temperature Kit Fluke 287 Kit Fluke 287 FlukeView® Forms Combo Kit Fluke 289 Fluke 289 True-RMS Industrial Logging Multimeter Fluke 289 Kit Fluke 289 FlukeView® Forms Combo Kit FLK-FC-SD CARD Fluke Connect Wireless SD Card FLK-Ti95 9HZ/FCA Ti95 Fluke Connect FCA Kit Fluke 287 Fluke 287 True-RMS Electronics Logging Multimeter FLK-Ti90 Fluke Ti90 Infrared Camera FLK-Ti95 Fluke Ti95 Infrared Camera FLK-Ti95 9HZ/FCC Ti95 Fluke Connect FCC Kit FLK-Ti100 Fluke Ti100 General Use Infrared Camera FLK-Ti105 Fluke Ti105 Infrared Camera for Industrial and Commercial Applications FLK-Ti105 30HZ/FCA Fluke Ti105 a3001 FC iFlex® Kit FLK-Ti110 Fluke Ti110 Infrared Camera for Industrial and Commercial Applications FLK-Ti125 Fluke Ti125 Industrial-Commercial Infrared Camera FLK-TiR105 Fluke TiR105 Infrared Camera FLK-TiR110 Fluke TiR110 Building Diagnostic Infrared Camera FLK-TiR125 Fluke TiR125 Infrared Camera FLK-Ti200 Fluke Ti200 Infrared Camera FLK-Ti300/FCA Kit Fluke Ti300 a3001 FC iFlex® Kit FLK-Ti400/FCA Kit Fluke Ti400 a3001 FC iFlex® Kit FLUKE-IR3000FC Fluke ir3000 FC Connector C3004IND Fluke C3004 Soft Case for FC Industrial System FLK-pc3000 FC Fluke pc3000 FC Wireless PC Adapter
-
-
-
Manuals
Title Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Users Manual Supplement Download Fluke Connect Quick Reference Guide Download Radio Frequency Data Class A Instruction Sheet Download Radio Frequency Data Class B Instruction Sheet Download TELE2, WIDE2, 4xTELE2, 25MAC2 CE Declaration of Conformity Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Quick Reference Guide Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Safety Sheet Supplement Download Ti200, Ti300, Ti400, Ti450, Ti450SF6, Ti480 Statement of Memory Volatility Download -
Application Notes
Title 6 tips to cut industrial and commercial energy costs Download Fluke Connect™ ABCs of DMMs Download Implementing an infrared thermography program Download Measuring three phase load draw with Fluke Connect® wireless tools Download Phase-to-phase troubleshooting with Fluke Connect® wireless tools Download Testing production controls with Fluke Connect® wireless tools Download Testing production line equipment with Fluke Connect® wireless tools Download Thermal imaging: Detecting electrical unbalance and overloads Download Thermal imaging: Implementing an infrared thermography maintenance program Download Thermal imaging: Infrared inspecting for building and facilities maintenance Download Thermal imaging: Inspecting electric motors Download Thermal imaging: Moisture in building envelopes Download Three-phase unbalance testing with Fluke Connect® wireless tools Download TI terminology Download -
Brochures
-
Data Sheets
-
Download the App
-
Related Links
-
Fluke Connect is not available in all countries.
©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.