Keeping your world up and running.®

Fluke CNXTM Ti125 Industrial System

A complete wireless measurement kit for Industrial applications. Capture up to five additional measurements with your CNX™ enabled Fluke Ti125 infrared camera.

This product is discontinued or reclassified

Fluke CNX Ti125 Industrial System
  • Fluke CNX Ti125 Industrial System
  • CNX i3000 Flex Clamp
  • Ti125 Taking Wireless Measurements
  • 3000 DMM
Overview
Features
Specs
Models
Resources
  • Get all the information you need to quickly troubleshoot problems with the Fluke CNX™ Ti125 Industrial System. Easily view both voltage and current readings simultaneously from a remote test point with your Ti125 thermal imaging camera. Use the modules as stand-alone measurement tools or combine to capture up to five critical measurements along with the infrared image. Simplify and streamline your reporting with our easy to use SmartView® Software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite. Work smarter and faster!

  • Get all the information you need to quickly troubleshoot problems with the Fluke Ti125 CNX Industrial Kit.

    The Ti125 Offers:

    • IR-Fusion® with AutoBlend- blends a digital and partially transparent IR image into a single image, making problem detection fast and easy.
    • Exclusive IR-OptiFlex™ focus system—ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
    • IR-PhotoNotes™ annotation system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
    • Multi-mode video recording—focus-free video in visible light and infrared with full IR-Fusion.
    • Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).
    The CNX™ i3000 iFlex AC Wireless Current Module Offers:
    • True-rms AC current measurements to 2500 A
    • 3% accuracy
    • Memory recording up to 65,000 readings
    • iFlex® current probe allows you to get into tight, awkward spaces
    • Backlit LCD display
    • CAT III 1000, CAT IV 600 V
    • IP42
  • Fluke Ti125 Infrared Camera
    Detailed Specifications
    IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
    Spectral band 7.5 μm to 14 μm (long wave)
    Capture or refresh rate 9 Hz or 30 Hz versions
    NETD (thermal sensitivity) ≤ 0.10 °C at 30 °C target temp (100 mK)
     0.10 °C at 30 °C target temp (100 mK)
    FOV (field of view) 22.5 °H x 31 °V
    IFOV (spatial resolution) 3.39 mRad
    Temperature measurement range (not calibrated below -10  °C) -20 °C to +350 °C (-4 °F to +662 °F)
    Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
    Focus mechanism IR-OptiFlex™ focus system
    IR-Fusion® technology PIP, FULL IR, FULL VISIBLE, AutoBlend™
    CNX™ wireless enabled Yes
    Color alarms High temperature, low temperature, isotherm
    Standard palettes Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
    Ultra Contrast™ palettes Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
    Hot/cold markers Yes
    User definable spot markers Three on camera and in SmartView®
    Centerbox (MIN/AVG/MAX) Yes
    Level and span control Manual and auto
    Minimum span in auto mode 5 °C
    Minimum span in manual mode 2.5 °C
    Minimum IR focus distance 15.25 cm (6 in)
    Weight 0.726 kg (1.6 lb)
    Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
    LCD display 3.5 inch diagonal (portrait format)
    Visible camera 2 megapixel industrial-grade
    Minimum automatic parallax correction ~18-22 inches
    IR-PhotoNotes™ annotation system Yes (3 images)
    Laser pointer Yes
    Torch Yes
    Electronic (cardinal) compass Yes
    Emissivity correction Yes
    Transmission correction Yes
    Background (reflected) compensation Yes
    Voice annotation (audio) Yes (60 seconds) per image
    Multi-mode video output Streaming USB video output (infrared, visible and IR-Fusion modes)
    Multi-mode video recording (standard avi w/ mpeg encoding) Yes (AVI with MPEG encoding, up to 5 minutes)
    Multi-mode video recording (radiometric .Is3) Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene
    Memory review Thumbnail review
    Battery (field-replaceable, rechargeable) Two
    Battery life 4+ hours (each)*
    External battery charging base Yes
    Charging power supply Yes
    Drop test 2 meter (6.5 feet)
    Ingress protection (IP) rating (IEC 60529) IP 54
    Recommended calibration cycle Two-years
    Multifunction card reader Included
    Memory storage 2 GB SD memory card
    Direct download capability Mini USB download direct to PC
    Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
    Operating humidity Operating and storage 10 % to 95 %, non-condensing
    Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
    Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
    C Tick IEC/EN 61326-1
    EMI, RFI, EMC EN61326-1; FCC Part 5
    User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
    Standard warranty period Two-years
    Extended warranty and service plans Yes

    *Assumes 50% brightness of LCD

     

    CNX™ 3000 Wireless Multimeter

    For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

    Detailed Specifications
    AC Voltage
    Range ¹ Resolution Accuracy ² ³
    45 Hz to 500 Hz 500 Hz to 1 kHz
    600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
    6.000 V 0.001 V
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V
    Notes:
    ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
    ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    Function Range Resolution Accuracy
    mV 600.0 mV 0.1 mV 0.09 % + 2
    V 6.000 V 0.001 V 0.09 % + 2
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V 0.15 % + 2
    Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω 600.0 Ω 0.1 Ω 0.5 % + 2
    6.000 kΩ 0.001 kΩ 0.5 % + 1
    60.00 kΩ 0.01 kΩ
    60.00 kΩ 0.1 kΩ
    600.0 kΩ 0.001 MΩ
    50.00 MΩ 0.01 MΩ 1.5 % + 3
    Diode test 2.000 V 0.001 V 1 % + 2
    μF 1000 nF 1 nF 1.2 % + 2
    10.00 μF 0.01 μF
    100.0 μF 0.1 μF
    9999 μF¹ 1 μF 10 % typical
    Notes:
    ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
    AC and DC Current
    Function Range ¹ Resolution Accuracy
    mA AC
    (45 Hz to 1 kHz)
    60.00 mA 0.01 mA 1.5 % + 3
    400.0 mA ³ 0.1 mA
    mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
    400.0 mA 0.1 mA
    Notes:
    ¹ All AC current ranges are specified from 5 % of range to 100 % of range.
    ² Input burden voltage (typical): 400 mA input 2 mV/mA.
    ³ 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range Resolution Accuracy ¹
    99.99 Hz 0.01 Hz 0.1 % + 1
    999.9 Hz 0.1 Hz
    9.999 kHz 0.001 kHz
    99.99 kHz 0.01 kHz
    Notes:
    ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Function Overload
    Protection
    Input Impedance
    (nominal)
    Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
    1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC,
    50 Hz or 60 Hz
    > 60 dB at 50 Hz or 60 Hz
    1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz  
    1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC,
    50 Hz or 60 Hz
    > 60 dB at 50 Hz or 60 Hz
    Open Circuit Test Voltage Full Scale Typical Short Circuit Current
    1100 V RMS < 2.7 V DC To 6 MΩ: < 0.7 V DC
    50 MΩ: < 0.9 V DC
    < 350 mA
    1100 V RMS < 2.7 V DC To 6 MΩ: 2.000 V DC < 1.1 mA
    Function Overload Protection Overload
    mA Fused, 44/100 A,
    1000 V FAST Fuse
    600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording
    Function Accuracy
    DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
    AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate: 4/sec
    Volts, amps, ohms: 6000 counts
    Frequency: 10,000 counts
    Capacitance: 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 300 hours minimum
    Temperature Operating: -10 °C to 50 °C
    Storage: -40 °C to 60 °C
    Relative humidity 0 % to 90 % (0 °C to 35 °C)
    0 % to 75 % (35 °C to 40 °C)
    0 % to 45 % (40 °C to 50 °C)
    Altitude Operating: 2,000 m
    Storage: 12,000 m
    Temperature coefficient 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
    Wireless frequency 2.4 GHz ISM Band 20 meter range
    Size (HxWxL) 4.75 cm x 9.3 cm x 20.7 cm
    (1.87 in x 3.68 in x 8.14 in)
    Weight 340 g (12 oz)
    Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    CE European: IEC/EN 61010-1:2010
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : T68-FWCS IC:6627A-FWCS
    Ingress Protection (IP) rating IP54
    Notes:
    • Accuracy is specified as ± ([% of reading] + [number of least significant digits]).
    • All ranges are autoranging.
    • Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

     

    Fluke CNX™ i3000 iFlex AC Wireless Current Module

    Specifications
    Range 2500 A AC
    Resolution 0.1 A to 999.9, 1A from 1000 to 2500
    Accuracy 3 % ± 5 digits
    Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
    Display 3-1/2 digits, LCD w/backlight
    Log rate/interval 1 sec minimum/adjustable by PC or front panel
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range 20 Meters
    Operating temperature -10 °C to +50 °C
    Storage temperature -40 °C to +60 °C
    Operating humidity 90 % at 35 °C
    75 % at 40 °C
    45 % at 50 °C
    EMC EN 61326-1:2006
    Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
    600 V Measurement Category (CAT) IV
    EN/IEC 61010-2-030:2010
    EN/IEC 610101-2-031:2002
    EN/IEC 61010-2-032:2002
    Pollution degree 2
    Temperature coefficient Add 0.1 X (specified accuracy) / °C per °C (<18 °C or >28 °C)
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
    Ingress Protection (IP) rating IP42
    Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
    Weight .22 kg (8 oz)
    Jaw opening 25.4 cm (10 in) coil

     

    Fluke CNX™ v3000 AC Wireless Voltage Module

    Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

    AC Voltage
    Range ¹ Resolution Accuracy ² ³
    45  Hz to 500 Hz 500 Hz to 1 kHz
    6.000 V 0.001 V 1.0 % + 3 2.0 % + 3
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V
    Notes:
    ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
    ² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V.
    ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
    General Specifications
    LCD w/backlight 3½ digits, 6000 counts, updates 4/sec
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    Unbound listen interval 5 seconds
    RF communications 2.4 GHZ ISM Band
    RF communication range 20 Meters
    Operating temperature -10 °C to +50 °C
    Storage temperature -40 °C to +60 °C
    Operating humidity 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
    EMC EN 61326-1:2006
    Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
    600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
    EN/IEC 61010-031:2002+A1:2008
    Pollution degree 2
    Temperature coefficient 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C)
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
    Ingress Protection (IP) rating IP42
    Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
    Weight .22 kg (8 oz)
    • Model
      Model Name Description  
      Fluke CNX™ Ti125 IND Fluke CNXTM Ti125 Industrial System
      Industrial System

      Includes:

      FLK-Ti125/IND 30 Hz:

      • Fluke Ti125 Infrared Camera
      • SmartView® Analysis and Reporting Software
      • Fluke CNX™ 3000 Wireless Multimeter
      • Fluke CNX™ v3000 AC Voltage Module
      • Fluke CNX™ i3000 iFlex® AC Wireless Current Modules - qty 3
      • iFlex® i2500-10 Flexible Current Probes - qty 3
      • Fluke CNX™ PC-3000 Wireless PC Adapter and Software
      • TL 224 Test Leads
      • TL 175 Test Leads
      • AC175 Alligator Clips
      • AC285 Alligator Clips
      • Magnetic Hanging Straps - qty 4

      FLK-Ti125/IND 9 Hz:

      • Fluke Ti125 Infrared Camera
      • SmartView® Analysis and Reporting Software
      • Fluke CNX™ 3000 Wireless Multimeter
      • Fluke CNX™ v3000 AC Voltage Module
      • Fluke CNX™ i3000 iFlex® AC Wireless Current Modules - qty 3
      • iFlex i2500-10 Flexible Current Probes - qty 3
      • Fluke CNX™ PC-3000 Wireless PC Adapter and Software
      • TL 224 Test Leads
      • TL 175 Test Leads
      • AC175 Alligator Clips
      • AC285 Alligator Clips
      • Magnetic Hanging Straps - qty 4
    • Manuals
      Title  
      CNX 3000 Safety Sheet Supplement Download
      CNX 3000 Statement of Memory Volatility Download
      CNX a3000 Calibration Manual Download
      CNX a3000 Quick Reference Guide Download
      CNX a3000 Safety Sheet Download
      CNX a3000 안전정보 Download
      CNX a3000 Safety Sheet Supplement Download
      CNX i3000 Calibration Manual Download
      CNX i3000 Quick Reference Guide Download
      CNX i3000 Safety Sheet Download
      CNX t3000 Quick Reference Guide Download
      CNX t3000 Safety Sheet Download
      CNX v3000 Calibration Manual Download
      CNX v3000 Quick Reference Guide Download
      CNX v3000 Safety Sheet Download
      CNX v3000, CNX t3000, CNX i3000, CNX a3000 Statement of Memory Volatility Download
      CNX x3000 CE Declaration of Conformity Download
      Ti100 Ti105, Ti110, Ti125, TiR100, TiR105, TiR110, TiR125 CE Declaration of Conformity Download
    • Brochures
      Title  
      Fluke CNX 3000TM Brochure Download
    • Data Sheets
      Title  
      Fluke CNXTM 3000 Data Sheet Download
      Ti125, Ti110, Ti105 and Ti100 Infrared Camera Industrial Technical Data Sheet Download
×