Keeping your world up and running.®

Fluke 971 Temperature Humidity Meter

Temperature and humidity are two important factors in maintaining optimal comfort levels and good indoor air quality. Quickly and conveniently take accurate humidity and temperature readings with the Fluke 971.

Fluke 971 Temperature Humidity Meter
  • Fluke 971 Temperature Humidity Meter
Overview
Features
Specs
Models
  • Temperature and humidity are two important factors in maintaining optimal comfort levels and good indoor air quality. Quickly and conveniently take accurate humidity and temperature readings with the Fluke 971. The Fluke 971 is invaluable for facility maintenance and utility technicians, HVAC-service contractors, and specialists who assess indoor air quality (IAQ). Lightweight and easy to hold, the Fluke 971 is the perfect tool for monitoring problem areas. With a rugged holster and protected sensor, the Fluke 971 is built to perform and made to last.

    • Backlit dual display of humidity and temperature
    • Measures dew point and wet bulb temperatures
    • 99 record storage capacity
    • Ergonomic design with belt clip and protective holster
    • Quick-response capacitance sensor
    • Compact and lightweight (188 g /6.6 oz)
    • Temperature range from -20°C to 60°C (-4°F to 140°F)
    • Relative humidity from 5% to 95%
    • Min/Max/Avg Data hold
    • Low battery indicator
  • Specifications
    Temperature -20°C to 60°C (-4°F to 140°F)
    Temperature accuracy 0°C to 45°C (±0.5°C)
    -20°C to 0°C & 45°C to 60°C (±1.0°C)
    32°F to 113°F (±1.0°F)
    -4°F to 32°F and 113°F to 140°F (±2.0°F)
    Resolution 0.1°C / 0.1°F
    Temperature update rate 500 ms
    Temperature sensor type NTC
    Relative humidity range 5% to 95% RH
    Relative humidity accuracy 10% to 90% RH @ 23°C (73.4°F) (±2.5% RH)
    (< 10%, > 90%RH @ 23°C (73.4°F) (±5.0% RH)
    Humidity densor Electronic capacitance polymer film sensor.
    Data storage capacity 99 points
    Response time (humidity) For 90% of total range - 60 s with 1 m/s air movement
    Environmental Specifications
    Operating temperature Temperature: -20°C to 60°C
    Humidity: 0°C to 55°C
    Storage temperature -20°C to 60°C at < 80% R.H. (with battery removed)
    Mechanical and General Specifications
    Weight 190 g (6.7 oz)
    Dimensions 194 x 60 x 34 mm
    Battery type 4 AAA alkaline batteries
    Battery Life 200 Hours
    • Models
      Model Name Description  
      Fluke 971 Fluke 971 Temperature Humidity Meter
       

      Includes:

      •     Operation manual
      •     4 AAA alkaline batteries