Keeping your world up and running.®

Fluke CNXTM 3000 Industrial System

The Fluke CNX™ 3000 Industrial System lets you work on electrical panels faster, safer, easier. Connect the remote modules, view readings from a distance.

This product is discontinued or reclassified

Fluke suggests:

Fluke 3000 FC Industrial System »

Fluke CNX™ 3000 Industrial System lets you work on electrical panels faster, safer, easier.
Overview
Features
Specs
Models
Accessories
Resources
  • The Fluke CNX™ 3000 Industrial System lets you work on electrical panels faster, safer, easier.

    Denergize the cabinet, connect the remote modules, close the cabinet and reenergize. The CNX™ 3000 Industrial System displays the readings wirelessly on the CNX multimeter.

    Connect the three CNX i3000 iFlex AC Wireless Current Modules to your test points, and view the results from all three phases in 1/3 the time and cost of current test methods. Or connect the CNX v3000 AC Wireless Voltage Module and view both voltage and current measurements simultaneously. You'll get better answers, faster, and spend less time in full PPE.

    From short distances, you can even view readings from modules through closed electrical panels. Plus the CNX remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm's way.

  • The CNX 3000 Industrial System provides measurement of all common electrical parameters.

    The CNX 3000 Wireless Multimeter offers:

    • True RMS AC and DC voltage measurements to 1000V
    • True RMS AC and DC current with 0.01 mA resolution
    • Continuity, resistance, diode test, capacitance and frequency measurements
    • MIN/MAX Recording
    • CAT III 1000 V; CAT IV 600 V; IP54

    The CNX i3000 iFlex AC Wireless Current Module offers:

    • True RMS AC current measurements to 2500 A
    • 3% accuracy
    • Memory recording up to 65,000 readings
    • iFlex current probe allows you to get into tight, awkward spaces
    • Backlit LCD display
    • CAT III 1000, CAT IV 600 V, CAT III 1000 V; IP42

    The CNX v3000 AC Wireless Voltage Module offers:

    • True RMS AC voltage measurements to 1000V
    • ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
    • Memory recording up to 65,000 readings
    • Backlit LCD display
    • CAT IV 600 V, CAT III 1000 V; IP42

    The CNX wireless system can track up to 10 measurement modules simultaneously, with results sent to a PC for detailed analysis.

  • CNX 3000 Wireless Multimeter

    For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

    Detailed Specifications
    AC Voltage
    Range ¹ Resolution Accuracy ² ³
    45 Hz to 500 Hz 500 Hz to 1 kHz
    600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
    6.000 V 0.001 V
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V
    Notes:
    ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
    ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    Function Range Resolution Accuracy
    mV 600.0 mV 0.1 mV 0.09 % + 2
    V 6.000 V 0.001 V 0.09 % + 2
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V 0.15 % + 2
    Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω 600.0 Ω 0.1 Ω 0.5 % + 2
    6.000 kΩ 0.001 kΩ 0.5 % + 1
    60.00 kΩ 0.01 kΩ
    60.00 kΩ 0.1 kΩ
    600.0 kΩ 0.001 MΩ
    50.00 MΩ 0.01 MΩ 1.5 % + 3
    Diode test 2.000 V 0.001 V 1 % + 2
    μF 1000 nF 1 nF 1.2 % + 2
    10.00 μF 0.01 μF
    100.0 μF 0.1 μF
    9999 μF¹ 1 μF 10 % typical
    Notes:
    ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
    AC and DC Current
    Function Range ¹ Resolution Accuracy
    mA AC
    (45 Hz to 1 kHz)
    60.00 mA 0.01 mA 1.5 % + 3
    400.0 mA ³ 0.1 mA
    mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
    400.0 mA 0.1 mA
    Notes:
    ¹ All AC current ranges are specified from 5 % of range to 100 % of range.
    ² Input burden voltage (typical): 400 mA input 2 mV/mA.
    ³ 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range Resolution Accuracy ¹
    99.99 Hz 0.01 Hz 0.1 % + 1
    999.9 Hz 0.1 Hz
    9.999 kHz 0.001 kHz
    99.99 kHz 0.01 kHz
    Notes:
    ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Function Overload
    Protection
    Input Impedance
    (nominal)
    Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
    1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC,
    50 Hz or 60 Hz
    > 60 dB at 50 Hz or 60 Hz
    1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz  
    1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC,
    50 Hz or 60 Hz
    > 60 dB at 50 Hz or 60 Hz
    Open circuit test voltage Full scale Typical short circuit current
    1100 V RMS < 2.7 V DC To 6 MΩ: < 0.7 V DC
    50 MΩ: < 0.9 V DC
    < 350 mA
    1100 V RMS < 2.7 V DC To 6 MΩ: 2.000 V DC < 1.1 mA
    Function Overload Protection Overload
    mA Fused, 44/100 A,
    1000 V FAST Fuse
    600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording
    Function Accuracy
    DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
    AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate: 4/sec
    Volts, amps, ohms: 6000 counts
    Frequency: 10,000 counts
    Capacitance: 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 300 hours minimum
    Temperature Operating: -10 °C to 50 °C
    Storage: -40 °C to 60 °C
    Relative humidity 0 % to 90 % (0 °C to 35 °C)
    0 % to 75 % (35 °C to 40 °C)
    0 % to 45 % (40 °C to 50 °C)
    Altitude Operating: 2,000 m
    Storage: 12,000 m
    Temperature coefficient 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
    Wireless frequency 2.4 GHz ISM Band 20 meter range
    Size (HxWxL) 4.75 cm x 9.3 cm x 20.7 cm
    (1.87 in x 3.68 in x 8.14 in)
    Weight 340 g (12 oz)
    Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    CE European: IEC/EN 61010-1:2010
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : T68-FWCS IC:6627A-FWCS
    Ingress Protection (IP) rating IP54
    Notes:
    • Accuracy is specified as ± ([% of reading] + [number of least significant digits]).
    • All ranges are autoranging.
    • Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

     

    Fluke CNX i3000 iFlex AC Wireless Current Module

    Specifications
    Range 2500 A AC
    Resolution 0.1 A to 999.9, 1A from 1000 to 2500
    Accuracy 3 % ± 5 digits
    Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
    Display 3-1/2 digits, LCD w/backlight
    Log rate/interval 1 sec minimum/adjustable by PC or front panel
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range 20 Meters
    Operating temperature -10 °C to +50 °C
    Storage temperature -40 °C to +60 °C
    Operating humidity 90 % at 35 °C
    75 % at 40 °C
    45 % at 50 °C
    EMC EN 61326-1:2006
    Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
    600 V Measurement Category (CAT) IV
    EN/IEC 61010-2-030:2010
    EN/IEC 610101-2-031:2002
    EN/IEC 61010-2-032:2002
    Pollution degree 2
    Temperature coefficient Add 0.1 X (specified accuracy) / °C per °C (<18 °C or >28 °C)
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
    Ingress Protection (IP) rating IP42
    Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
    Weight .22 kg (8 oz)
    Jaw opening 25.4 cm (10 in) coil

     

    Fluke CNX v3000 AC Wireless Voltage Module

    Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

    AC Voltage
    Range ¹ Resolution Accuracy ² ³
    45  Hz to 500 Hz 500 Hz to 1 kHz
    6.000 V 0.001 V 1.0 % + 3 2.0 % + 3
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V
    Notes:
    ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
    ² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V.
    ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
    General Specifications
    LCD w/backlight 3½ digits, 6000 counts, updates 4/sec
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    Unbound listen interval 5 seconds
    RF communications 2.4 GHZ ISM Band
    RF communication range 20 Meters
    Operating temperature -10 °C to +50 °C
    Storage temperature -40 °C to +60 °C
    Operating humidity 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
    EMC EN 61326-1:2006
    Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
    600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
    EN/IEC 61010-031:2002+A1:2008
    Pollution degree 2
    Temperature coefficient 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C)
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
    Ingress Protection (IP) rating IP42
    Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
    Weight .22 kg (8 oz)
    • Model
      Model Name Description  
      CNX 3000 IND Fluke CNXTM 3000 Industrial System
      Industrial System

      Includes:

      • Fluke CNX 3000 Wireless Multimeter
      • Fluke CNX v3000 AC Wireless Voltage Module
      • Three (3) Fluke CNX i3000 iFlex AC Wireless Current Modules
      • Three (3) iFlex i2500-10 Flexible Current Probes
      • Fluke CNX pc3000 Wireless PC Adapter and Software
      • TL224 Test Leads
      • TL175 Test Leads
      • AC175 Alligator Clips
      • AC285 Alligator Clips
      • Four (4) Magnetic Hanging Straps
    • Cases & Holsters
      Model Name Description  
      CNX C3000 Fluke CNXTM C3000 Premium Modular Tool Bag
      CNX C3001 Fluke CNXTM C3001 Modular Small Case
      CNX C3002 Fluke CNXTM C3002 Modular DMM 2-Compartment Soft Case
      CNX C3003 Fluke CNXTM C3003 Modular 3-Compartment Soft Case
    • Clips
      Model Name Description  
      Fluke AC285 Fluke AC285 SureGripTM Alligator Clips Fluke Store
    • Current Probes
      Model Name Description  
      Fluke i2500 10 Fluke i2500-10 iFlex® Flexible Current Probes
    • Test Leads
      Model Name Description  
      Fluke TL224 Fluke TL224 SureGripTM Insulated Test Leads Fluke Store
    • Test Leads, Probes & Clips
      Model Name Description  
      Fluke TL175 Fluke TL175 TwistGuardTM Test Leads Fluke Store
    • Wireless Accessories
      Model Name Description  
      CNX pc3000 Fluke CNXTM pc3000 PC Adapter and Software
    • Related Products
      Model Name Description  
      CNX 3000 Fluke CNXTM 3000 Wireless Multimeter
      CNX v3000 Fluke CNXTM v3000 AC Wireless Voltage Module
      CNX pc3000 Fluke CNXTM pc3000 PC Adapter and Software
      CNX 3000 GM Fluke CNXTM 3000 General Maintenance System
      CNX v3000 Fluke CNXTM v3000 AC Voltage Kit
      CNX 3000 HVAC Fluke CNXTM 3000 HVAC System
      CNX C3000 Fluke CNXTM C3000 Premium Modular Tool Bag
      CNX C3001 Fluke CNXTM C3001 Modular Small Case
      CNX C3002 Fluke CNXTM C3002 Modular DMM 2-Compartment Soft Case
      CNX C3003 Fluke CNXTM C3003 Modular 3-Compartment Soft Case
    • Manuals
      Title  
      CNX 3000 用户手册 Download
      CNX 3000 使用手冊 Download
      CNX 3000 Brugsanvisning Download
      CNX 3000 Handleiding Download
      CNX 3000 Users Manual Download
      CNX 3000 Käyttöohje Download
      CNX 3000 Mode d'emploi Download
      CNX 3000 Bedienungshandbuch Download
      CNX 3000 Manuale per l’uso Download
      CNX 3000 ユーザーズ・マニュアル Download
      CNX 3000 사용자 설명서 Download
      CNX 3000 Brukerhåndbok Download
      CNX 3000 Instrukcja użytkownika Download
      CNX 3000 Manual do usuário Download
      CNX 3000 Руководство пользователя Download
      CNX 3000 Manual de uso Download
      CNX 3000 Användarhandbok Download
      CNX 3000 Kullanım Kılavuzu Download
      CNX 3000 User's Manual Supplement Download
      CNX 3000 Calibration Manual Download
      CNX 3000 Instruction Sheet Download
      CNX 3000 Quick Reference Guide Download
      CNX 3000 安全数据单 Download
      CNX 3000 安全資訊 Download
      CNX 3000 Sikkerhedsblad Download
      CNX 3000 Veiligheidsinformatieblad Download
      CNX 3000 Safety Sheet Download
      CNX 3000 Turvaohjeet Download
      CNX 3000 Fiche de sécurité Download
      CNX 3000 Sicherheitsdatenblatt Download
      CNX 3000 Foglio delle informazioni di sicurezza Download
      CNX 3000 Safety Sheet Download
      CNX 3000 안전정보 Download
      CNX 3000 Sikkerhetsdatablad Download
      CNX 3000 Informacje na temat bezpiecze ń stwa Download
      CNX 3000 Folha de Segurança Download
      CNX 3000 Информация по технике безопасности Download
      CNX 3000 Hoja de seguridad Download
      CNX 3000 Säkerhetsdatablad Download
      CNX 3000 Güvenlik Bilgileri Download
      CNX 3000 Safety Sheet Supplement Download
      CNX 3000 Statement of Memory Volatility Download
      CNX a3000 Calibration Manual Download
      CNX a3000 Quick Reference Guide Download
      CNX a3000 安全数据单 Download
      CNX a3000 安全資訊 Download
      CNX a3000 Sikkerhedsblad Download
      CNX a3000 Veiligheidsinformatieblad Download
      CNX a3000 Safety Sheet Download
      CNX a3000 Turvaohjeet Download
      CNX a3000 Fiche de sécurité Download
      CNX a3000 Sicherheitsdatenblatt Download
      CNX a3000 Foglio delle informazioni di sicurezza Download
      CNX a3000 Safety Sheet Download
      CNX a3000 안전정보 Download
      CNX a3000 Sikkerhetsdatablad Download
      CNX a3000 Informacje na temat bezpieczeństwa Download
      CNX a3000 Folha de Segurança Download
      CNX a3000 Информация по технике безопасности Download
      CNX a3000 Hoja de seguridad Download
      CNX a3000 Säkerhetsdatablad Download
      CNX a3000 Güvenlik Bilgileri Download
      CNX a3000 Safety Sheet Supplement Download
      CNX i3000 Calibration Manual Download
      CNX i3000 Quick Reference Guide Download
      CNX i3000 安全数据单 Download
      CNX i3000 安全資訊 Download
      CNX i3000 Sikkerhedsblad Download
      CNX i3000 Veiligheidsinformatieblad Download
      CNX i3000 Safety Sheet Download
      CNX i3000 Turvaohjeet Download
      CNX i3000 Fiche de sécurité Download
      CNX i3000 Sicherheitsdatenblatt Download
      CNX i3000 Foglio delle informazioni di sicurezza Download
      CNX i3000 Safety Sheet Download
      CNX i3000 안전정보 Download
      CNX i3000 Sikkerhetsdatablad Download
      CNX i3000 Informacje na temat bezpiecze ń stwa Download
      CNX i3000 Folha de Segurança Download
      CNX i3000 Информация по технике безопасности Download
      CNX i3000 Hoja de seguridad Download
      CNX i3000 Säkerhetsdatablad Download
      CNX i3000 Güvenlik Bilgileri Download
      CNX t3000 Calibration Manual Download
      CNX t3000 Quick Reference Guide Download
      CNX t3000 安全数据单 Download
      CNX t3000 安全資訊 Download
      CNX t3000 Sikkerhedsblad Download
      CNX t3000 Veiligheidsinformatieblad Download
      CNX t3000 Safety Sheet Download
      CNX t3000 Turvaohjeet Download
      CNX t3000 Fiche de sécurité Download
      CNX t3000 Sicherheitsdatenblatt Download
      CNX t3000 Foglio delle informazioni di sicurezza Download
      CNX t3000 Safety Sheet Download
      CNX t3000 안전정보 Download
      CNX t3000 Sikkerhetsdatablad Download
      CNX t3000 Informacje na temat bezpiecze ń stwa Download
      CNX t3000 Folha de Segurança Download
      CNX t3000 Информация по технике безопасности Download
      CNX t3000 Hoja de seguridad Download
      CNX t3000 Säkerhetsdatablad Download
      CNX t3000 Güvenlik Bilgileri Download
      CNX v3000 Calibration Manual Download
      CNX v3000 Quick Reference Guide Download
      CNX v3000 安全数据单 Download
      CNX v3000 安全資訊 Download
      CNX v3000 Sikkerhedsblad Download
      CNX v3000 Veiligheidsinformatieblad Download
      CNX v3000 Safety Sheet Download
      CNX v3000 Turvaohjeet Download
      CNX v3000 Fiche de sécurité Download
      CNX v3000 Sicherheitsdatenblatt Download
      CNX v3000 Foglio delle informazioni di sicurezza Download
      CNX v3000 Safety Sheet Download
      CNX v3000 안전정보 Download
      CNX v3000 Sikkerhetsdatablad Download
      CNX v3000 Informacje na temat bezpiecze ń stwa Download
      CNX v3000 Folha de Segurança Download
      CNX v3000 Информация по технике безопасности Download
      CNX v3000 Hoja de seguridad Download
      CNX v3000 Säkerhetsdatablad Download
      CNX v3000 Güvenlik Bilgileri Download
      CNX v3000, CNX t3000, CNX i3000, CNX a3000 Statement of Memory Volatility Download
      CNX x3000 CE Declaration of Conformity Download
      pc 3000 FC Instruction Sheet Download
      Radio Frequency Data Class B Instruction Sheet Download
    • Application Notes
      Title  
      Troubleshooting power harmonics Download
      Who sets the rules for electrical testing and safety? Download
      Wireless test tools can cut troubleshooting time Download
    • Brochures
      Title  
      Fluke CNX 3000TM Brochure Download
    • Case Studies
      Title  
      Use Study: Bill Wedge / Electrical Download
      Use Study: Bill Weindorf / Electrical Download
      Use Study: Bob Axelson / HVAC Download
      Use Study: Dave Buhrmester / Industrial Download
      Use Study: Fluke CNXTM Download
      Use Study: Jon Pike / Hospital Download
      Use Study: Leigh Copp / Industrial Download
      Use Study: Pat Weldon / Transportation Download
      Use Study: Rick Ramirez / Industrial Download
      Use Study: Tim Rao / Industrial Download
    • Data Sheets
      Title  
      Fluke CNXTM Application Illustration - All Download
      Fluke CNXTM Application Illustration - Detecting Power Interruption Download
      Fluke CNXTM Application Illustration - Determining Current Imbalance Download
      Fluke CNXTM Application Illustration - Load Study Download
      Fluke CNXTM Application Illustration - Measure Incoming Current Download
      Fluke CNXTM Application Illustration - Measure Incoming Voltage Download
      Fluke CNXTM Application Illustration - Measuring Ground Fault Currents Download
      Fluke CNXTM Application Illustration - Production Test Download
      Fluke CNXTM Application Illustration - Single Phase Measurement Procedures Download
×
×
×