Keeping your world up and running.®

Fluke 3000 FC General Maintenance System

Fluke 3000 FC General Maintenance System lets you work on electrical panels faster, safer, easier. Connect the remote modules, view readings from a distance.

Get a Free Demo
Fluke 3000 FC General Maintenance System
  • Fluke 3000 FC General Maintenance System
  • Fluke 3000 FC Series Wireless Multimeter with Fluke Connect® Assets
  • Fluke Connect® Asset Health Status over time
  • 3000 FC wireless multimeter
Overview
Features
Reviews
Specs
Models
Accessories
Resources
  • Fluke Connect®

    See How It Works »
    Fluke Connect FAQs »

    The Fluke FC Wireless General Maintenance System lets you work on electrical panels faster, safer, easier

    Connect the FC Wireless iFlex® AC Current Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Or connect the FC Wireless AC Voltage Module and view both voltage and current measurements simultaneously.

    You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.

    From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the Fluke Connect remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

    Now you can take readings on moving machinery, with only the measurement module in harm’s way.

  • The Fluke 3000 FC General Maintenance System provides measurement of all common electrical parameters

    The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting:

    • AC and DC voltage measurements to 1000V
    • AC and DC current with 0.01 mA resolution
    • Continuity, resistance, diode test, capacitance and frequency measurements
    • MIN/MAX recording
    • CAT III 1000 V, Cat IV 600 V; IP54

    The Fluke v3000 FC Wireless AC Voltage Module offers:

    • Measurements up to 1000 V true-RMS AC
    • Use as a standalone meter or as part of the system
    • A logging function for recording and saving up to 65,000 readings

    The Fluke v3001 FC Wireless DC Voltage Module lets you:

    • Measure up to 1000 V DC
    • Use as a standalone meter or as part of the system
    • Use the logging function for recording and saving up to 65,000 readings

    The Fluke a3001 FC Wireless iFlex® AC Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier:

    • Measure up to 2500 A AC
    • Use as a standalone meter or as part of the system
    • Logging function for recording and saving up to 65,000 readings
    • Inrush function
  • Fluke 3000 FC Series Wireless Multimeter

    * For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).

    Detailed Specifications
    AC Voltage
    Range ¹ / Resolution 600.0 mV / 0.1 mV
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 2 3 4 45 Hz to 500 Hz 1.0% + 3
    500 Hz to 1 kHz 2.0% + 3
    1. All AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    Function
    mV Range / Resolution 600.0 mV / 0.1 mV
    Accuracy 0.09% + 2
    V Range / Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 0.09% + 2
    0.15% + 2
    ))) Range / Resolution 600 Ω / 1 Ω
    Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω Range / Resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    60.00 kΩ / 0.1 kΩ
    600.0 kΩ / 0.001 MΩ
    50.00 MΩ / 0.01 MΩ
    Accuracy 0.5% + 2
    0.5% + 1
    1.5% + 3
    Diode test Range / Resolution 2.000 V / 0.001 V
    Accuracy 1% + 2
    µF
    Range / Resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF1 / 1 μF
    Accuracy 1.2% + 2
    10% typical
    1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    Function
    mA AC
    (45 Hz to 1 kHz)
    Range 1 / Resolution 60.00 mA / 0.01 mA
    400.0 mA 3/ 0.1 mA
    Accuracy 1.5% + 3
    mA DC 2 Range 1 / Resolution 60.00 mA / 0.01 mA
    400.0 mA 3/ 0.1 mA
    Accuracy 0.5% + 3
    1. All AC current ranges are specified from 5% of range to 100% of range.
    2. Input burden voltage (typical): 400 mA input 2 mV/mA.
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range / Resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 kHz
    99.99 kHz / 0.01 kHz
    Accuracy 1 0.1% + 1
    1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Function Overload
    protection
    Input impedance
    (nominal)
    Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection
    1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
    1100 Vrms > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz > 60 dB at 50 Hz or 60 Hz
    1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
    Open circuit test voltage Full scale voltage Typical short circuit current
    To 6 MΩ 50 MΩ Typical short circuit current
    1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA
    1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
    mA Function
    Overload protection Fused, 44/100 A, 1000 V FAST Fuse
    Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording Accuracy
    DC functions The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
    AC functions The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate 4/sec
    Volts, amps, ohms 6000 counts
    Frequency 10,000 counts
    Capacitance 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
    Temperature Operating -10°C to 50°C
    Storage -40°C to 60°C
    Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Relative humidity 0% to 90% (0°C to 35°C)
    0% to 75% (35°C to 40°C)
    0% to 45% (40°C to 50°C)
    Altitude Operating 2,000 m
    Storage 12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008,
    FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    UL 61010-1: 3rd edition
    IEC/EN 61010-1:2010
    Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    Weight 340 g (12 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools

    Fluke v3000 FC Wireless AC Voltage Module

    Accuracy is specified as ±([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5% to 100% of the range obtained by autoranging, from 18°C to 28°C.

    Specifications
    Range ¹ / Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 2 3 4 45 Hz to 500 Hz 1.0% + 3
    500 Hz to 1 kHz 2.0% + 3
    1. All AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    General Specifications
    LCD w/ backlight 3½ digits, 6000 counts, updates 4/sec
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 Hours
    Memory Record up to 65000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient 0.1 x (specified accuracy)/ °C (< 18°C or > 28°C)
    Operating humidity 90% at 35°C, 45% at 40°C, 45% at 50°C
    Altitude Operating 2,000 m
    Storage 12,000 m
    EMC EN 61326-1:2006
    Safety compliance ANSI/ISA 61010-1 / (82.02.01) 3rd edition
    CAN/CSA-C22.2 No 61010-1-12 3rd edition
    UL 61010-1 3rd edition
    IEC/EN 61010-1 2010
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Pollution Degree 2
    Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
    Weight .22 kg (8 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools

    Fluke v3001 FC Wireless DC Voltage Module

    Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [ Number of least significant digits ]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18°C to 28°C.

    Voltage Specifications
    Function
    mVDC Range ¹ / Resolution 600.0 mV / 0.1 mV
    Accuracy 0.09% + 3
    VDC Range ¹ / Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy 0.09% + 3
    Range ¹ / Resolution 1000 V / 1 V
    Accuracy 0.15% + 2
    General Specifications
    LCD w/backlight 3 ½ digits, 6000 counts, 4/sec update rate
    Battery type 2 AA Alkaline batteries, NEDA 15A, IEC LR6
    Log rate/interval Adjustable by PC from 1 sec to 1 hr, default 1 min
    Battery life 400 hours minimum
    Memory Record up to 65,000 readings
    RF communications 2.4 GHz ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient 0.1 x (specified accuracy)/ °C (< 18°C or > 28°C)
    Relative humidity 0% to 90% (0°C to 35°C), 0% to 75% (35°C to 40°C),
    0% to 45% (40°C to 50°C)
    EMC IEC 61236-1, Portable
    Safety compliance IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Size (H x W x D) 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in)
    Weight 0.255 kg (9 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools

    Fluke a3001 FC Wireless iFlex® AC Current Module

    Specifications
    Range 0.5 A to 2500 A AC
    Resolution 0.1 A
    Accuracy 3% ±5 digits (5 Hz to 500 Hz)
    Crest factor (50 Hz / 60 Hz) 3.0 at 1100 A
    2.5 at 1400 A
    1.42 at 2500 A
    add 2% for C.F. > 2
    LCD w/ backlight 3½ digits
    Log rate/interval 1 sec minimum/adjustable by PC or front panel
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient Add 0.1 x (specified accuracy) /°C (< 18°C or > 28°C)
    Operating humidity 90% at 35°C
    75% at 40°C
    45% at 50°C
    Altitude Operating 2,000 m
    Storage 12,000 m
    EMC EN 61326-1:2006
    Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Pollution Degree 2
    Jaw opening 25.4 cm (10 in) coil
    Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
    Weight .22 kg (8 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools
    • Models
      Model Name Description  
      FLK-3000 FC GM Fluke 3000 FC General Maintenance System
       

      Includes:

      • Fluke 3000 FC Series Wireless Multimeter
      • Fluke v3000 Voltage Module
      • Fluke v3001 Voltage Module
      • Fluke a3001 FC Wireless iFlex AC Current Module
      • TL224 Test Leads
      • TL222 Test Leads
      • TL175 Test Leads
      • AC285 Alligator Clips
      • AC220 Alligator Clips
      • AC175 Alligator Clips
      • iFlex i2500-10 Flexible Current Probe
      • Magnetic hanging strap
    • Test Leads, Probes & Clips
      Model Name Description  
      Fluke TL175 Fluke TL175 TwistGuardTM Test Leads Fluke Store
    • Wireless Accessories
      Model Name Description  
      FLK-pc3000 FC Fluke pc3000 FC Wireless PC Adapter
    • Related Products
      Model Name Description  
      FLK-A3004 FC Fluke a3004 FC Wireless 4-20 mA DC Clamp Meter
      FLK-A3003 FC Fluke a3003 FC Wireless 2000 A DC Current Clamp Meter
      FLK-Ti400 Fluke Ti400 Infrared Camera
      FLK-Ti200 Fluke Ti200 Infrared Camera
      FLK-Ti300 Fluke Ti300 Infrared Camera
      FLK-3000 FC Fluke 3000 FC Series Wireless Multimeter
      FLK-A3000 FC Fluke a3000 FC Wireless AC Current Clamp Module
      FLK-A3001 FC Fluke a3001 FC Wireless iFlex® AC Current Module
      FLK-A3002 FC Fluke a3002 FC Wireless AC/DC Current Module
      FLK-3000 FC HVAC Fluke 3000 FC HVAC System
      FLK-3000 FC IND Fluke 3000 FC Industrial System
      FLK-A3000 FC Kit Fluke a3000 FC Wireless AC Current Clamp Kit
      FLK-A3001 FC Kit Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
      FLK-T3000 FC Fluke t3000 FC Wireless Temperature Module
      FLK-V3000 FC Fluke v3000 FC Wireless AC Voltage Module
      FLK-V3000 FC Kit Fluke v3000 FC Wireless AC Voltage Kit
      FLK-V3001 FC Fluke v3001 FC Wireless DC Voltage Module
      FLK-T3000 FC Kit Fluke t3000 FC Wireless Temperature Kit
      FLK-V3001 FC Kit Fluke v3001 FC Wireless DC Voltage Kit
      FLK-V3003 FC Kit Fluke v3003 FC Wireless AC-DC Voltage Measurement Kit
      Fluke-789 FC/t3000 Fluke 789 FC ProcessMeterTM and Temperature Kit
      Fluke 287 Kit Fluke 287 FlukeView® Forms Combo Kit
      Fluke 289 Fluke 289 True-RMS Industrial Logging Multimeter
      Fluke 289 Kit Fluke 289 FlukeView® Forms Combo Kit
      FLK-FC-SD CARD Fluke Connect Wireless SD Card
      FLK-Ti95 9HZ/FCA Ti95 Fluke Connect FCA Kit
      Fluke 287 Fluke 287 True-RMS Electronics Logging Multimeter
      FLK-Ti90 Fluke Ti90 Infrared Camera
      FLK-Ti95 Fluke Ti95 Infrared Camera
      FLK-Ti95 9HZ/FCC Ti95 Fluke Connect FCC Kit
      FLK-Ti100 Fluke Ti100 General Use Infrared Camera
      FLK-Ti105 Fluke Ti105 Infrared Camera for Industrial and Commercial Applications
      FLK-Ti105 30HZ/FCA Fluke Ti105 a3001 FC iFlex® Kit
      FLK-Ti110 Fluke Ti110 Infrared Camera for Industrial and Commercial Applications
      FLK-Ti125 Fluke Ti125 Industrial-Commercial Infrared Camera
      FLK-TiR105 Fluke TiR105 Infrared Camera
      FLK-TiR110 Fluke TiR110 Building Diagnostic Infrared Camera
      FLK-TiR125 Fluke TiR125 Infrared Camera
      FLK-Ti200/FCA KIT Fluke Ti200 a3001 FC iFlex® Kit
      FLK-Ti300/FCA Kit Fluke Ti300 a3001 FC iFlex® Kit
      FLK-Ti400/FCA Kit Fluke Ti400 a3001 FC iFlex® Kit
      FLUKE-IR3000FC Fluke ir3000 FC Connector
      C3004IND Fluke C3004 Soft Case for FC Industrial System
      FLK-pc3000 FC Fluke pc3000 FC Wireless PC Adapter

Fluke Connect is not available in all countries.

©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

×
×
×