Designed by Electricians. Engineered by Fluke – An Investment in Accuracy
With its integrated non-contact voltage detection and the AutoV/LoZ function preventing false readings caused by ghost voltage, the Fluke 117 Electrician's Multimeter is the ideal multimeter for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings, measuring frequency and capacitance. With its easy-to-use design, the Fluke 117 will save you time, allowing you to move from job to job with ease.
Engineered and Tested with Your Safety on the Job in Mind
We test our 117 Multimeters for safe use in CAT III 600 V environments. This is the ideal meter for your electrical work because:
- The large white LED backlight helps you work in poorly lit areas
- VoltAlertTM technology gives you fact, go/no go non-contact voltage detection
- AutoVolt and Low Input Impedance modes provide faster, more accurate readings
-

- VoltAlert™ technology for non-contact voltage detection
- AutoVolt automatic AC/DC voltage selection
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- True RMS for accurate measurements on non-linear loads
- Measures 10 A (20 A overload for 30-seconds)
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™) for hands free operation
- CAT III 600 V safety rated
-
Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Battery type 9 volt Alkaline, NEDA 1604A / IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/resolution 600.0 mV / 0.1 mV Accuracy ±([% of reading] + [counts]): 0.5% + 2 DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 VAccuracy ±([% of reading] + [counts]): 0.5% + 2 Auto volts Range/resolution 600.0 V / 0.1 V Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 VAccuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)Continuity Range/resolution 600 Ω / 1 Ω Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩAccuracy 0.9% + 1 Range/resolution 40.00 MΩ / 0.01 MΩ Accuracy 5% + 2 Diode test Range/resolution 2.00 V / 0.001 V Accuracy 0.9% + 2 Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μFAccuracy 1.9% + 2 Range/resolution > 1000 μF Accuracy 5% + 20% Lo-Z capacitance Range 1 nF to 500 μF Accuracy 10% + 2 typical AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 AAccuracy 1.5% + 3
20 A continuous overload for 30 seconds maxDC amps Range/resolution 6.000 A / 0.001 A 10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A continuous overload for 30 seconds maxHz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 HzAccuracy 0.1% + 2 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.Mechanical and General Specifications Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) Weight 550 g Warranty 3 years -
-
Models
Model Name Description Fluke 117 Fluke 117 Electrician's Digital Multimeter with Non-Contact Voltage Includes:
- 4 mm silicone test lead set
- Holster
- User manual
-
-
-
Cases & Holsters
Model Name Description Fluke C50 Fluke C50 Meter Case Fluke Store Fluke C90 Fluke C90 Soft Case for DMM and Visual IR Thermometers Fluke Store Fluke CXT170 Fluke CXT170 Extreme Case Fluke Store Fluke TPAK Fluke TPAK ToolPakTM Magnetic Meter Hanger Fluke Store -
Clips
Model Name Description Fluke AC285 Fluke AC285 SureGripTM Alligator Clips Fluke Store Fluke AC87 Fluke AC87 Heavy Duty Bus Bar Clip Set Fluke Store -
Compatible Products
Model Name Description Fluke LVD1 Fluke LVD1 Volt Light Fluke Store -
Current Clamps
Model Name Description Fluke i200s Fluke i200s AC Current Clamp Fluke Store Fluke i400s Fluke i400s AC Current Clamp Fluke Store -
Light
Model Name Description Fluke L206 Fluke L206 Deluxe LED Hat Light Fluke Store -
Options
Model Name Description Fluke MeterCleaner Wipes Fluke MeterCleanerTM Wipes Fluke Store -
Temperature Accessories
Model Name Description Fluke 80PK-9 Fluke 80PK-9 General Purpose Probe Fluke Store Fluke 80TK Fluke 80TK Thermocouple Module Fluke Store -
Test Leads
Model Name Description Fluke TL220 Fluke TL220 SureGripTM Industrial Test Lead Set Fluke Store Fluke TL223 Fluke TL223 SureGripTM Electrical Test Lead Set Fluke Store Fluke TL71 Fluke TL71 Premium Test Lead Set Fluke Store -
Test Leads, Probes & Clips
Model Name Description Fluke TL175 Fluke TL175 TwistGuardTM Test Leads Fluke Store -
Related Products
Model Name Description Fluke 110 Plus Fluke 110 Plus Digital Multimeter Fluke 117/323 Kit Fluke 117/323 Electricians Multimeter Combo Kit Fluke 117/322 Kit Fluke 117/322 Electrician’s Multimeter Combo Kit Fluke 116/62 MAX+ Kit Fluke 116/62 MAX+ Technician’s Combo Kit Fluke 116/323 Kit Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter Fluke 116/322 Kit Fluke 116/322 HVAC Combo Kit - Includes Multimeter and Clampmeter Fluke 116 Fluke 116 Digital Multimeter Fluke 115 Fluke 115 Digital Multimeter Fluke 114 Fluke 114 Digital Multimeter Fluke 113 Fluke 113 Digital Multimeter
-
-
Product Registration
-
Manuals
Title 114, 115, 117 使用手冊 Download 114, 115, 117 Uživatelská příručka Download 114, 115, 117 Brugsanvisning Download 114, 115, 117 Handleiding Download 114, 115, 117 Users Manual Download 114, 115, 117 Käyttöohje Download 114, 115, 117 Mode d'emploi Download 114, 115, 117 Bedienungshandbuch Download 114, 115, 117 Manuale per l’uso Download 114, 115, 117 Users Manual Download 114, 115, 117 사용자 설명서 Download 114, 115, 117 Brukerhåndbok Download 114, 115, 117 Instrukcja użytkownika Download 114, 115, 117 Manual do usuário Download 114, 115, 117 Руководство пользователя Download 114, 115, 117 Manual de uso Download 114, 115, 117 Användarhandbok Download 114, 115, 117 คมอผใช Download 114, 115, 117 Users Manual Supplement Download 110 Plus,113, 114, 114C, 115, 115C, 116, 116C, 117, 117C CSA Certificate of Conformity Download 113 Calibration Information Supplement Download 113 Instruction Sheet Supplement Download 113, 114, 114C, 115, 115C, 116, 116C, 117, 117C TUV SUD Certificate of Conformity Download 114, 115, 116, and 117 Calibration Information Download 114, 115, 116, and 117 Calibration Information Supplement Download 117, 116, 115, 114, 113 and 110 Plus Statement of Memory Volatility Download Fluke 110 Plus, 113, 114, 115, 116, and 117 CE Declaration of Conformity Download -
Application Notes
-
Brochures
-
Data Sheets
-
Related Links
-