Keeping your world up and running.®

Fluke 117/322 Electrician’s Multimeter Combo Kit

Fluke 117/322 Electrician’s Combo Kit pairs with Fluke 117 electrician’s multimeter; 3 year warranty & Fluke 322 for one total solution.

This product is discontinued or reclassified

Overview
Specs
Models
Resources
  •  This combo kit pairs the new Fluke 117 DMM with a Fluke 322 clamp meter for productive and effective troubleshooting in one total solution, including the new C115 durable soft carrying case for protection and easy meter transportation.

    3 years warranty on Fluke 117 DMM, 2 years warranty on Fluke 322 Clamp meter and 1 year on accessories.

  • Fluke 117 Digital Multimeter

    Specifications
    Maximum voltage between any terminal and earth ground 600 V
    Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
    Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
    Display Digital: 6,000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating temperature -10 °C to + 50 °C
    Storage temperature -40 °C to + 60 °C
    Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery life 400 hours typical, without backlight
    Accuracy Specifications
    DC millivolts Range/Resolution 600.0 mV / 0.1 mV
    Accuracy ± ([% of reading] + [counts]): 0.5% + 2
    DC volts Range/Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy ± ([% of reading] + [counts]): 0.5% + 2
    Auto volts Range/Resolution 600.0 V / 0.1 V
    Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
    4.0 % + 3 (500 Hz to 1 kHz)
    AC millivolts¹ True RMS Range/Resolution 600.0 mV / 0.1 mV
    Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
    2.0 % + 3 (500 Hz to 1 kHz)
    AC volts¹ True RMS Range/Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
    2.0 % + 3 (500 Hz to 1 kHz)
    Continuity Range/Resolution 600 Ω / 1 Ω
    Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of
    500 μs or longer.
    Ohms Range/Resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy 0.9 % + 1
    Range/Resolution 40.00 MΩ / 0.01 MΩ
    Accuracy 5 % + 2
    Diode test Range/Resolution 2.00 V / 0.001 V
    Accuracy 0.9% + 2
    Capacitance Range/Resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
    Accuracy 1.9% + 2
    Range/Resolution > 1000 μF
    Accuracy 5% + 20%
    Lo-Z capacitance Range 1 nF to 500 μF
    Accuracy 10% + 2 typical
    AC amps True RMS (45 Hz to 500 Hz) Range/Resolution 6.000 A / 0.1 A
    10.00 A / 0.01 A
    Accuracy 1.5% + 3
    20 A continuous overload for 30 seconds max
    DC amps Range/Resolution 6.000 A / 0.1 A10.00 A / 0.01 A
    Accuracy 1.0% + 3
    20 A continuous overload for 30 seconds max
    Hz (V or A input)² Range/Resolution 99.99 Hz / 0.01 Hz
    999.99 Hz / 0.1 Hz
    9.999 Hz / 0.001 Hz
    50.00 Hz / 0.01 Hz
    Accuracy 0.1% + 2

    Notes:

    1. All AC voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    4. Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F.
    Mechanical & General Specifications
    Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
    Weight 550 g
    Warranty 3 years

     

    Fluke 322 Clamp Meter

    Specifications
    Voltage DC Range / Resolution 0 - 400 V / 0.1 V
    0 - 600 V / 1 V
    Accuracy 1% ± 5 counts
    Voltage AC Range / Resolution 0 - 400 V / 0.1 V
    0 - 600 V / 1 V
    Accuracy 1.2% ± 5 counts (50 - 400 Hz)
    AC Response Averaging
    Current AC Range / Resolution 0 - 400 A / 0.1 A
    0 - 40 A / 0.01 A
    Accuracy 1.8% ± 5 counts (50 - 60 Hz)
    3.0% ± 5 counts (60 - 400 Hz)
    AC Response Averaging
    Resistance Range / Resolution 0 - 400 Ω / 0.1 Ω
    Accuracy 1% ± 5 counts
    Continuity   <= 30 Ω
    Environmental Specifications
    Operating Temperature -10°C to +50°C
    Storage Temperature -30 ºC to +60 ºC
    Operating Altitude 2,000 meters
    Temperature De-rating Add 0.1 x specified accuracy for each ºC above 28ºC or below 18ºC
    Safety Specifications
    Safety Rating IEC 1010-2-032, 600V CAT III
    Mechanical and General Specifications
    Size 190 x 63 x 35 mm
    Weight 230 g
    Warranty Two years
    Battery Life 100 hours typical (2 AAA carbon zinc)
    Jaw Opening 25 mm
    • Models
      Model Name Description  
      Fluke 117/322 Kit Fluke 117/322 Electrician’s Multimeter Combo Kit
       

      Included:

      • Fluke 117 True RMS digital multimeter with non-contact voltage detection
      • Fluke 322 Compact clamp meter
      • TPAK Magnetic Meter Hanging Strap
      • TL75 Hard Point test lead set
      • C115 Deluxe soft carrying case with shoulder strap
    • Manuals
      Title  
      110 Plus,113, 114, 114C, 115, 115C, 116, 116C, 117, 117C CSA Certificate of Conformity Download
      113 Calibration Information Supplement Download
      113 Instruction Sheet Supplement Download
      113, 114, 114C, 115, 115C, 116, 116C, 117, 117C TUV SUD Certificate of Conformity Download
      117, 116, 115, 114, 113 and 110 Plus Statement of Memory Volatility Download
      Fluke 110 Plus, 113, 114, 115, 116, and 117 CE Declaration of Conformity Download
    • Application Notes
      Title  
      Troubleshooting power harmonics Download