Keeping your world up and running.®

Fluke a3000 FC Wireless AC Current Clamp Kit

Fluke Connect Wireless test tools show real-time measurements from remote modules up to 20 meters away. Simultaneous readings on a single screen.

Get a Free Demo
Fluke a3000 FC Wireless AC Current Clamp Kit
  • Fluke a3000 FC Wireless AC Current Clamp Kit
  • Fluke 3000 FC Series Wireless Multimeter with Fluke Connect® Assets
  • Fluke Connect® Asset Health Status over time
  • 3000 FC wireless multimeter
Overview
Features
Reviews
Specs
Models
Accessories
Resources
  • Fluke Connect®

    See How It Works »
    Fluke Connect FAQs »

    The Fluke a3000 FC Wireless AC Current Clamp Kit is part of the Fluke Connect™ team of wireless test tools

    Connect the a3000 FC Wireless AC Current Clamp Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.

    You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.

    From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Clamp Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

    Now you can take readings on moving machinery, with only the measurement module in harm’s way.

  • The Fluke a3000 FC Wireless AC Current Clamp Kit provides measurement of many common electrical parameters

    The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting:

    • AC and DC voltage measurements to 1000V
    • AC and DC current with 0.01 mA resolution
    • Continuity, resistance, diode test, capacitance and frequency measurements
    • MIN/MAX recording
    • CAT III 1000 V, Cat IV 600 V; IP54

    The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:

    • True-RMS AC clamp meter
    • Measure up to 400 A AC
    • Use as a standalone meter or as part of the system
    • Logging function for recording and saving up to 65,000 readings
    • Inrush function
  • Fluke 3000 FC Series Wireless Multimeter

    * For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).

    AC Voltage
    Range¹ / resolution   600.0 mV / 0.1 mV
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy2 3 4 45 Hz to 500 Hz 1.0% + 3
    500 Hz to 1 kHz 2.0% + 3
    1. All AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    mV Range / resolution 600.0 mV / 0.1 mV
    Accuracy 0.09% + 2
    V Range / resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 0.09% + 2
    0.15% + 2
    ))) Range / resolution 600 Ω / 1 Ω
    Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω Range / resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    60.00 kΩ / 0.1 kΩ
    600.0 kΩ / 0.001 MΩ
    50.00 MΩ / 0.01 MΩ
    Accuracy 0.5% + 2
    0.5% + 1
    1.5% + 3
    Diode test Range / resolution 2.000 V / 0.001 V
    Accuracy 1% + 2
    µF
    Range / resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF1 / 1 μF
    Accuracy 1.2% + 2
    10% typical
    1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    mA AC
    (45 Hz to 1 kHz)
    Range1 / resolution 60.00 mA / 0.01 mA
    400.0 mA3/ 0.1 mA
    Accuracy 1.5% + 3
    mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
    400.0 mA3/ 0.1 mA
    Accuracy 0.5% + 3
    1. All AC current ranges are specified from 5% of range to 100% of range.
    2. Input burden voltage (typical): 400 mA input 2 mV/mA.
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range / resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 kHz
    99.99 kHz / 0.01 kHz
    Accuracy1 0.1% + 1
    1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Overload protection 1100 Vrms
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 120 dB at DC, 50 Hz or 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Overload protection 1100 Vrms
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 60 dB, DC to 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Overload protection 1100 Vrms
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 120 dB at DC, 50 Hz or 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Open Circuit Test Voltage
    Overload protection 1100 Vrms
    Input impedance (nominal) < 2.7 VDC
    Full scale voltage to 6 MΩ
    Full scale voltage 50 MΩ
    < 0.7 VDC
    < 0.9 VDC
    Typical short circuit current < 350 mA
    Overload protection 1100 Vrms
    Input impedance (nominal) < 2.7 VDC
    Full scale voltage to 6 MΩ
    Full scale voltage 50 MΩ
    2.000 VDC
    Typical short circuit current < 1.1 mA
    mA Function
    Overload protection Fused, 44/100 A, 1000 V FAST Fuse
    Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording Accuracy
    DC functions ±12 counts for changes > 350 mS in duration.
    AC functions ±40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate 4/sec
    Volts, amps, ohms 6000 counts
    Frequency 10,000 counts
    Capacitance 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
    Temperature Operating -10°C to 50°C
    Storage -40°C to 60°C
    Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Relative humidity 0% to 90% (0°C to 35°C)
    0% to 75% (35°C to 40°C)
    0% to 45% (40°C to 50°C)
    Altitude Operating 2,000 m
    Storage 12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008
    FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    UL 61010-1: 3rd edition
    IEC/EN 61010-1:2010
    Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    Weight 340 g (12 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools

    Fluke a3000 FC Wireless AC Current Clamp Module

    Specifications
    Range 0.5 A to 400.0 A
    Resolution 0.1 A
    Accuracy 400.0 A: 2% ±5 digits (10 Hz to 100 Hz), 2.5% ±5 digits (100 Hz to 500 Hz)
    Inrush Max displayed reading 999.9A
    Crest factor (50 Hz / 60 Hz) 3 at 500 A
    2.5 at 600 A
    1.42 at 1000 A
    Add 2% for C.F. > 2
    LCD w/backlight 3½ digits
    Log rate/interval 1 sec minimum/adjustable by PC
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Operating humidity 90% at 35°C
    75% at 40°C
    45% at 50°C
    Altitude Operating 2,000 m
    Storage 12,000 m
    EMC EN 61326-1:2006
    Safety compliance IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
    Safety rating CAT III 600 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP30
    Pollution Degree 2
    Jaw opening 34 mm (1.33 in)
    Size (H x W x D) 20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in)
    Weight .22 kg (8 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools
    • Models
      Model Name Description  
      FLK-a3000 FC KIT Fluke a3000 FC Wireless AC Current Clamp Kit
       

      Includes:

      • Fluke 3000 FC Series Wireless Multimeter
      • Fluke a3000 FC Wireless AC Current Clamp Module
      • TL175 Test Leads
      • AC175 Alligator Clips
    • Test Leads, Probes & Clips
      Model Name Description  
      Fluke TL175 Fluke TL175 TwistGuardTM Test Leads Fluke Store
    • Wireless Accessories
      Model Name Description  
      FLK-pc3000 FC Fluke pc3000 FC Wireless PC Adapter
    • Related Products
      Model Name Description  
      FLK-A3004 FC Fluke a3004 FC Wireless 4-20 mA DC Clamp Meter
      FLK-A3003 FC Fluke a3003 FC Wireless 2000 A DC Current Clamp Meter
      FLK-Ti400 Fluke Ti400 Infrared Camera
      FLK-Ti200 Fluke Ti200 Infrared Camera
      FLK-Ti300 Fluke Ti300 Infrared Camera
      FLK-3000 FC Fluke 3000 FC Series Wireless Multimeter
      FLK-A3000 FC Fluke a3000 FC Wireless AC Current Clamp Module
      FLK-A3001 FC Fluke a3001 FC Wireless iFlex® AC Current Module
      FLK-A3002 FC Fluke a3002 FC Wireless AC/DC Current Module
      FLK-3000 FC GM Fluke 3000 FC General Maintenance System
      FLK-3000 FC HVAC Fluke 3000 FC HVAC System
      FLK-3000 FC IND Fluke 3000 FC Industrial System
      FLK-A3001 FC Kit Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit
      FLK-T3000 FC Fluke t3000 FC Wireless Temperature Module
      FLK-V3000 FC Fluke v3000 FC Wireless AC Voltage Module
      FLK-V3000 FC Kit Fluke v3000 FC Wireless AC Voltage Kit
      FLK-V3001 FC Fluke v3001 FC Wireless DC Voltage Module
      FLK-T3000 FC Kit Fluke t3000 FC Wireless Temperature Kit
      FLK-V3001 FC Kit Fluke v3001 FC Wireless DC Voltage Kit
      FLK-V3003 FC Kit Fluke v3003 FC Wireless AC-DC Voltage Measurement Kit
      Fluke-789 FC/t3000 Fluke 789 FC ProcessMeterTM and Temperature Kit
      Fluke 287 Kit Fluke 287 FlukeView® Forms Combo Kit
      Fluke 289 Fluke 289 True-RMS Industrial Logging Multimeter
      Fluke 289 Kit Fluke 289 FlukeView® Forms Combo Kit
      FLK-FC-SD CARD Fluke Connect Wireless SD Card
      FLK-Ti95 9HZ/FCA Ti95 Fluke Connect FCA Kit
      Fluke 287 Fluke 287 True-RMS Electronics Logging Multimeter
      FLK-Ti90 Fluke Ti90 Infrared Camera
      FLK-Ti95 Fluke Ti95 Infrared Camera
      FLK-Ti95 9HZ/FCC Ti95 Fluke Connect FCC Kit
      FLK-Ti100 Fluke Ti100 General Use Infrared Camera
      FLK-Ti105 Fluke Ti105 Infrared Camera for Industrial and Commercial Applications
      FLK-Ti105 30HZ/FCA Fluke Ti105 a3001 FC iFlex® Kit
      FLK-Ti110 Fluke Ti110 Infrared Camera for Industrial and Commercial Applications
      FLK-Ti125 Fluke Ti125 Industrial-Commercial Infrared Camera
      FLK-TiR105 Fluke TiR105 Infrared Camera
      FLK-TiR110 Fluke TiR110 Building Diagnostic Infrared Camera
      FLK-TiR125 Fluke TiR125 Infrared Camera
      FLK-Ti200/FCA KIT Fluke Ti200 a3001 FC iFlex® Kit
      FLK-Ti300/FCA Kit Fluke Ti300 a3001 FC iFlex® Kit
      FLK-Ti400/FCA Kit Fluke Ti400 a3001 FC iFlex® Kit
      FLUKE-IR3000FC Fluke ir3000 FC Connector
      C3004IND Fluke C3004 Soft Case for FC Industrial System
      FLK-pc3000 FC Fluke pc3000 FC Wireless PC Adapter

Fluke Connect is not available in all countries.

©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

×
×
×