Keeping your world up and running.®

Fluke 215C/S

Fluke 215C/S digital scopemeters offer powerful testing capabilities for a wide variety of industrial bus systems & overall signal quality.

This product is discontinued or reclassified

Fluke 215C/S
Overview
Features
Specs
Models
Accessories
Resources
  • Fluke 215C/SColor ScopeMeter with Industrial Bus Health Test capability

    The 225C offers the full functionality of a standard 200 MHz portable oscilloscope yet with the addition of powerful test capabilities for a wide variety of Industrial Bus systems. When in Bus health Test mode, the 225C ScopeMeter will automatically make an analysis of the electrical signals passing through the bus, and compare the parameters to standard values as described in the industry standards for that bus type. Alternatively, the user may select an ‘Eyepattern’ display to visually check the overall signal quality.

    Parameters are automatically qualified as ‘good’, ‘weak’ or ‘bad’ based on a comparison to the appropriate industrial standards or to user set reference values. Each of the measured parameters is presented with momentary value and with statistical minimum and maximum values measured over time. The reference values used are also displayed, to give the user an easier grip on the systems behavior. Tested parameters include signal amplitudes, bias voltage, rise- and fall-times, jitter, distortion and noise levels (in-band noise as well as out-of-band noise) depending on the requirements of the associated industry standard.

  • The Fluke 225C is the instruments of choice for maintenance specialists who deal with industrial buses and networks as well as with general electronics. You can verify the electrical integrity of your bus and network, performing ‘physical layer tests’ and getting answers quickly and easily.

    Based on the 200 MHz or 100 MHz 190C Series Color ScopeMeter test tools, these instruments offer all functions found in the 190C Series, with Bus Health Test capabilities added on top. 

    Bus Health Test
    Bus Health Test analyses the electrical signals on the industrial bus or network and gives a clear “Good, “Weak or “Bad validation mark for each of the relevant parameters, presented next to the actual measurement value. Measured values are compared to standard values based on the selected bus type, or you may set your personal reference values if you need different tolerances.


    Automatic analysis and validation of electrical signal parameters

    All common bus types are supported
    The 225C ScopeMeter test tool supports not just one or two bus systems but all commonly seen industrial buses. From the lower speed AS-i and CAN to the higher speed Ethernet 100Base-T based systems are covered by a single instrument. A simple menu structure allows for selecting the main bus type and, where applicable, sub-types listed in a sub-menu for easy selection. Tested parameters and reference values are then set according the selection made.


    All common bus types are supported and accessible through a simple menu structure

    Large color screen
    The large color screen of the 225C shows the individual parameters with validation, the actual measured value, the minimum and maximum values recorded over time, and the reference values used for the validation. The choice of parameters differs with the bus type and may include bias voltage, signal high- and low-levels, rise- and fall-times, in-band and out-of-band noise levels, jitter, pulse width, baud rate, and more. The activity indicators tell you the data is ongoing and they stop the moment communications come to a halt.

    Making test connections
    The large screen also gives wiring information for each of the supported bus types, giving the user guidance in making the test connections. A set of break-out adapters is included with the 225C to give access to each of the wires and pins of the commonly used connection systems M12, DB-9 and RJ-45.


    On screen ‘help’ information includes visual guidance on making the test connections. The independently isolated input channels of the 225C support truly differential measurements on bus systems.


    BHT190 Break-out adapter with DB-9 connectors gives access to all individual wires and pins of the connection system.

    Eye-pattern Mode
    The Fluke 225C can make the signal quality validation as soon as electrical signals are passed along the network, without looking at the data content. They find errors like improper cable connections, bad contacts, incorrect grounding and missing or superfluous terminators. In the eye-pattern mode, a waveform display is built over successive signal passes to give you a visual indication of overall signal quality, noise levels and signal jitter, using the scope’s user selectable persistence mode.


    Eye-pattern mode allows for a visual check of signal quality

    Floating independently isolated input channels
    Thanks to the independently isolated input channels and the floating inputs, the ScopeMeter test tool can take truly floating differential measurements from balanced 2-wire systems such as RS-485 and CAN, giving a high level of suppression for common mode disturbances and noise. One input channel can be connected to measure the voltage between the two signal wires, and the other can be connected to measure the common mode voltage over ground at the same time, independently. This way, you may also measure the signals passing through the twisted wires of the 100Base-T Ethernet.


    Isolated, floating channels give a high immunity to common mode noise and allow for direct measurements on balanced, two-wire systems including Ethernet 100Base-T.

    Fluke 225C compared with other ScopeMeter test tools 
    All ScopeMeter test tools allow you to perform the basic electrical tests (such as copper resistance and isolation tests) on an electrical system or a cable. The Fluke 125 offers a cost-effective solution for making tests on industrial buses and networks, using a common reference (‘ground’) connection. The Fluke 125 also includes a fully featured 40 MHz Industrial ScopeMeter. The 225C gives more extensive industrial bus signal analysis capabilities. Thanks to the isolated channel structure, the 225C gives a far better immunity to common mode noise and disturbances and can measure common mode voltages separately. On top, the 225C comes with higher measurement speeds and give you all the measurement capabilities associated with the 190C Series.

    Apart from the Bus Health Test functionality, the 225C incorporates the full functionality of the 199C and 196C Color ScopeMeters.

  • For the Fluke 225C, the full specifications of the 199C (196C) applies.

     

    Specifications
    Bandwith
    225C:  200 MHz
    Sample rate:
    225C:  2.5 GS/s
    Bus health test:
       Verifies the electrical parameters of industrial bus systems using automatic measurement and analysis functions. Next to that, an Eyepattern mode is provided for visual inspection of signal quality.
    Parameter classification:
       Default values:
     well within limits = ‘good’, gives green tick mark
     within specified percentage of the limit values = ‘weak’, gives orange tickmark
     beyond limit values = ‘bad’, gives red tickmark
       Limits values, as a default, are based on industry standard for the selected bus type or may be set by the user. The tolerance band (percentage) taken into account for the classification ‘weak’ may be altered by the user.
    Bus systems supported:
     AS-i (EN50295, 166 kb/s);
     CAN-bus (ISO-11898, up to 1 Mb/s);
     Modbus 232 (EIA-232 up to 115 kb/s);
     Modbus 485 (EIA-485 up to 10 Mb/s);
     Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s);
     Profibus DP (EIA-485 up to 12 Mb/s);
     Profibus PA (61158 type 1, 31.25 kb/s);
     Ethernet 10Base2 (coaxial, 10 Mb/s);
     Ethernet 10BaseT (UTP, 10 Mb/s);
     Ethernet 100BaseT (100 Mb/s);
     RS-232 (EIA-232, up to 115 kb/s);
     RS-485 (EIA-485, up to 10 Mb/s).
    Modes:
     Waveform Parameter analysis with automatic read-out and parameter validation (good / weak / bad); test limits are based on industry standards or may be set by the user.
     Eyepattern display mode.
    Measured parameters (where applicable):
     bias voltage level,
     signal amplitude,
     pulse width or baud rate,
     risetime,
     fall time,
     jitter,
     signal distortion,
     noise HF,
     noise LF,
     in-band noise.
    Eyepattern display mode:
       Gives waveform display of bus signals with user selectable persistence of the display. Timebase, attenuator and persistence settings may be altered by the user.
    Persistence modes:
       off – short – medium – long – infinite
    • Model
      Model Name Description  
      Fluke 215C/S Fluke 215C/S
      ScopeMeter with Bus Health Test, SCC-190 included

      Color ScopeMeter (100 MHz, 1 GS/s) with Bus Health test capabilities built-in, with SCC-kit

    • Manuals
      Title  
      19xC-2x5C Users Manual Download
      192/196/199 & 196C/199C Programmers Guide Download
      192B, 196B, 199B, 192C, 196C, 199C, 215C, 225C Statement of Memory Volatility Download
      19xC-2x5C Getting Started Download