Keeping your world up and running.®

Fluke i2000 Flex AC Current Clamp

Fluke i2000 flex AC Current Clamp
Overview
Features
Specs
Models
Accessories
Resources
  • The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

    • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
    • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
    • Maximum conductor diameter 178 mm
    • CAT III 600 V safety rating
  • Electrical specifications
    Current ranges 20 A
    200 A
    2000 A
    AC rms
    Output sensitivity (AC-coupled) 1 mV
    10 mV
    100 mV
    1 mV per A
    Load impedance 100 kΩ minimum
    Accuracy at +25°C
    ±1% of range (45 Hz to 65 Hz)
    Linearity 10% to 100% of range
    ±0.2% of reading
    Noise 8 mV AC rms (30 A)
    2 mV AC rms (300 A, 3000 A)
    Frequency range 10 Hz to 20 kHz (-3 dB)
    Phase error < ±1° (45 Hz to 65 Hz)
    ±10° (at 20 kHz)
    Position sensitivity with cable > 25 mm from the coupling
    ±2% of range
    External field with cable > 200 mm from the head
    ±1% of range
    Power supply 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
    Temperature Coefficient ±0.08% of reading per °C
    Working voltage see Safety standards section
    600 V AC rms or DC
    General Specifications
    Head Circumference 610 mm (24 in)
    Head cable diameter 14.3 mm (0.56 in)
    Head bend radius 38.1 mm (1.5 in)
    Cable length (head to electronics) 2 m (6.56 ft)
    Output connection Molded 4 mm safety plugs (not integrated)
    Operating temperature range 0°C to +70°C (32°F to 158°F) (head and electronics)
    Storage temperature range -40°C to +105°C (-40°F to 221°F) (head)
    -20°C to +85°C (-4°F to 185°F) (electronics)
    Operating humidity 15% to 85% (non-condensing)
    Weight 180 g (6.34 oz) (head)
    190 g (6.70 oz) (electronics)
    Safety standards EN 61010-031: 2002
    EN 61010-2-032: 2002
    EN 61010-1: 2001
    600 Vrms, Category III, Pollution Degree 2
    Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
    EMC standards EN 61326: 1998 +A1, A2, and A3
    Dimensions (H x W x D) 116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in)
    • Model
      Model Name Description  
      Fluke i2000 Flex Fluke i2000 Flex AC Current Clamp
    • Compatible Products
      Model Name Description  
      Fluke 175 Fluke 175 True RMS Digital Multimeter
      Fluke 177 Fluke 177 True RMS Digital Multimeter
      Fluke 179 Fluke 179 True RMS Digital Multimeter
      Fluke 233 Fluke 233 Remote Display Digital Multimeter
      Fluke 27 II Fluke 27 II Rugged Digital Multimeter
      Fluke 28 II Fluke 28 II Rugged Digital Multimeter
      Fluke 287 Fluke 287 True-RMS Electronics Logging Multimeter
      Fluke 289 Fluke 289 True-RMS Industrial Logging Multimeter
      Fluke 83V Fluke 83V Average Responding Industrial Multimeter
      Fluke 87V Fluke 87V Industrial Multimeter
    • Manuals
      Title  
      i2000flex Instruction Sheet Download
      i2000flex Fiche d´instruction Download
      i2000flex Anleitungsblatt Download
      i2000flex Foglio di istruzioni Download
      i2000flex Hoja de instrucciones Download
      i3000s/i2000 Flex Instruction Sheet Download
      i3000s/i2000 Flex Instruction Sheet Download
      i3000s/i2000 Flex Instruction Sheet Download
      i3000s/i2000 Flex Instruction Sheet Download
      i3000s/i2000 Flex Instruction Sheet Download
      i3000s/i2000 Flex Instruction Sheet Download
      i3000s/i2000 Flex Instruction Sheet Download